Рет қаралды 4,116
Quick Configuration of Schneider ATV12H018M2 0.18kW
Parameters:
MOTOR CONTROL (ConF - FuLL - drC)
bFr - Standard motor frequency [Hz]
nPr - Nominal motor power on motor nameplate
nPr - Nominal motor current on motor nameplate [A]
THERMAL PROTECTION (ConF - FuLL - Flt - tHt)
itH - Nominal motor current on motor nameplate [A]
CONFIGURATION (ConF)
ACC- Acceleration Time (s)
deC - Deceleration time (s)
LSP - Motor frequency at minimum reference [Hz]
HSP -Motor frequency at maximum reference [Hz]
CONTROL MENU (ConF - FuLL Ctl )
Fr1 - Reference control (potentiometer)
tCC - Command control - 2C - 2wire 3C - 3wire
User Manual: www.se.com/pl/...
#automation #automatyk #mechatronic #technical #engineering #engineer #weekend #plc #vs #versus #automatyka #automatic