Seismic Load Calc Example

  Рет қаралды 46,776

professordeb

professordeb

Күн бұрын

Пікірлер: 59
@sci-fimodeler1701
@sci-fimodeler1701 Ай бұрын
Thank you for your video. I am studying for the SE exam and every example helps. I still have my HP 15C
@professordeb
@professordeb 19 күн бұрын
I'm glad it was helpful. I'm just a PE...surprised that this basic content is useful enough to prep for the rigors of an SE exam! Those old HP calculators from the '80s just can't be beat!
@josedelpino6676
@josedelpino6676 Жыл бұрын
I am an Aerospace Engineer working a unique Civl Engineering project with seismic assesment requirements and found your lecture very informative and straightforward to understand, thank you very muc for your contribution for us in the technical world!
@professordeb
@professordeb Жыл бұрын
Thank you so much. Made for my basic architectural structures class, but glad it was helpful for you!
@abo11007
@abo11007 2 жыл бұрын
Please continue for more examples
@vinayakkrishnaprasad358
@vinayakkrishnaprasad358 3 жыл бұрын
Thank you Proffesor. Best explanation On the Internet.
@professordeb
@professordeb 3 жыл бұрын
Thank you so much...glad it wad helpful. 😊
@AmanSingh-us5wr
@AmanSingh-us5wr 6 жыл бұрын
Well laid out and clearly explained. Please try to upload more educational videos.
@brandon1770
@brandon1770 5 жыл бұрын
This video was everything I was looking for and more. Awesome job explaining everything!
@professordeb
@professordeb 5 жыл бұрын
Glad it's helpful!
@nasratullahamarkhail3217
@nasratullahamarkhail3217 Жыл бұрын
Amazing, clear and to the point explanation. Thank you @professordeb!
@Shehryk9
@Shehryk9 Жыл бұрын
This helped me so much at work, thank you!!
@mattowens7548
@mattowens7548 5 жыл бұрын
Very good, simple way to explain how to get the forces. Thanks!
@Anghel57190
@Anghel57190 2 жыл бұрын
Wonderful presentation.
@petariivanov7750
@petariivanov7750 6 жыл бұрын
Thank you for uploading this video! Very clear and easy to follow.
@anandgold1
@anandgold1 3 жыл бұрын
thanks a ton maam, more power to you from india
@khalilahmad882
@khalilahmad882 4 жыл бұрын
Excellent explanation Maam
@carloscm1323
@carloscm1323 4 жыл бұрын
Beautiful calculator
@professordeb
@professordeb 4 жыл бұрын
Thank you....One of the most iconic calculators, the venerable HP 11C! Been using it since the early '80s.
2 жыл бұрын
Thanks, that was a great and clear video, I certainly learnt
@AT-wx2bw
@AT-wx2bw 5 жыл бұрын
Well Expalined for Structural Engineers!
@denniscolardo9773
@denniscolardo9773 2 жыл бұрын
Good day maam if im going to calculate a seismic load on vertical storage tank? Still the same formula or what is the difference?
@professordeb
@professordeb 2 жыл бұрын
Sorry, that's a question outside the scope of things here. I make these specifically for my students in architecture but post them here for general info. The process here also is using older code provisions that have been superseded. The basic principles would be the same for a storage tank, though, that seismic forces come from inertial mass of whatever is being stored in the tank. I suggest you look at other more technically-based structures links. Dr. Structure here on KZbin might be a good place to start.
@Mrjrphoen
@Mrjrphoen 3 жыл бұрын
excellent! I really enjoyed it, very clear presentation. @ 20.08 for wind loads, you had mentioned the wind loads be the same. But the wall length are different, can you comment on that? @ 4.52, would the weight be the same if it were wind loads, 1/2 of 2-walls plus roof weight? thanks
@professordeb
@professordeb 3 жыл бұрын
Thanks...glad it was helpful. The wind load *pressure* is assumed to be the same in all directions. The total wind *force*, however, depends on how long the wall is to accumulate that pressure. For the second question, the wall and roof dead loads are what generate the seismic forces in a building by virtue of their inertia. Wind loads in contrast act externally to the wall, so the wall weights are not part of load computation.
@ahsanhabib8171
@ahsanhabib8171 3 жыл бұрын
nice presentation
@rodolforodriguez70
@rodolforodriguez70 5 жыл бұрын
Thank you for this great Video Professor
@professordeb
@professordeb 5 жыл бұрын
You’re welcome...glad it was helpful.
@nadernader6420
@nadernader6420 Жыл бұрын
GREAT THANKS, PROF. DEB. COULD YOU PLEASE EXPLAIN TO US THE DISTRIBUTION OF SEISMIC LOADS ON STORAGE TANKS, THANKS A LOT
@tedmankowski7505
@tedmankowski7505 2 жыл бұрын
Hi professor Deb. Do you have an example for designing cast-in-drilled-hole (CIDH) steel reinforced concrete piers? I have software to design the pier itself, but not sure how to establish horizontal seismic force for each pier (lateral loads near slopes already provide by my Geotech). I was proposing that I could take the tributary total dead load and simply multiply it by the calculated base shear factor of approximately .14W here in California zone 4. This is for my own residential foundation repair design. Thanks so much ! Ted
@professordeb
@professordeb 2 жыл бұрын
Hi Ted...sorry no, that's really outside the scope of the type of videos I make for my students. For a real project on your own house subject to the seismic loads you really need to consult with a licensed structural engineer. So much depends on the soil type of your foundations as well as the dead load of the house. 14% of your dead load may or may not be high enough for your location. The resonant interaction between the natural periods of vibration of the building and soil are a critical concern. Designing for seismic resistance is NOT a do-it-yourself job! This is not to even mention the necessary anchors and straps required throughout the house to maintain a continuous load path from the roof to the foundation.
@seryunkwak1824
@seryunkwak1824 4 жыл бұрын
I am new to the structural analysis. Roof DL (North-South) should be calculated 15 psf * 1 ft (12" strip a.k.a tributary width) which indicates the linear load along 60' long section?
@professordeb
@professordeb 4 жыл бұрын
I'm not quite sure if that's a question or a statement. If it's a question, maybe you could rephrase it as I'm not quite sure what is being asked. The loads computed in the N-S direction are those that accumulate (plus the wall DL) along the 100' width of the building, That force is then in turn resisted the the exterior N-S walls on the east and west faces that carries it to the foundation,
@seryunkwak1824
@seryunkwak1824 4 жыл бұрын
​@@professordeb Why was the Roof DL(15 psf) multiplied by "60ft" for N-S?
@XdaedosX
@XdaedosX 5 жыл бұрын
This was a very good video. Excellent step-by-step explanations with clear diagrams. Thank you!
@professordeb
@professordeb 2 жыл бұрын
Thanks...glad it was helpful.
@asianvalvesrajan
@asianvalvesrajan 4 жыл бұрын
Excellent article, congratulation, Could you give a lecture of Example for calculation of seismic loads for a conventional valve., like Globe valve as it may be useful for valve enginers
@professordeb
@professordeb 4 жыл бұрын
Thank you, glad it helps. As far as valves are concerned, that's really outside of my expertise, sorry!
@khaibarrahimy6437
@khaibarrahimy6437 3 жыл бұрын
At the end when you find reaction R, why you divide the value by 2? Is it because we have 2 walls on that row or something else?
@professordeb
@professordeb 3 жыл бұрын
Because it acts like a simple-span beam...half the load goes to each end reaction.
@mienge2177
@mienge2177 4 жыл бұрын
Professor how do i find the earthquake load that we put in to load the combination equation is that the base shear value or the resultant value of all floor or each story? which value do I use to check the earthquake load combination? Thanks.
@professordeb
@professordeb 4 жыл бұрын
In multistory structures the base shear is the total due to the inertial forces accumulating from top to bottom of the structure. This base shear then gets distributed to each level of the structure as a percentage of the total. Codes have a formula for that that also consider the mass of each floor level and period of vibration, all of which is beyond the scope of what I cover here in this basic example.
@joro8604
@joro8604 5 жыл бұрын
What is the program you are using for the demo?
@professordeb
@professordeb 5 жыл бұрын
The 3D graphics are Rhino, the 2D illustration was done with Illustrator.
@vec5d
@vec5d 5 жыл бұрын
Really appreciated!
@divyangsoni1845
@divyangsoni1845 4 жыл бұрын
Which code does this example follow?
@professordeb
@professordeb 4 жыл бұрын
This is based on an old code in the United States (the Uniform Building Code of 1998), which is quite simplified from current codes. The intent of this example is to explain the basic principle of how seismic loads are generated and move through a structure without getting overly complex.
@divyangsoni1845
@divyangsoni1845 4 жыл бұрын
@@professordeb Understood. Thank You.!
@bluesky12644
@bluesky12644 4 жыл бұрын
simple and clear, thanks
@nooralanoor3493
@nooralanoor3493 6 жыл бұрын
Excellent video thanks to upload.
@professordeb
@professordeb 6 жыл бұрын
Glad it helps! Thanks for your comment.
@Amerikanin2numarali_ustasi
@Amerikanin2numarali_ustasi 4 жыл бұрын
yes!
@edwintmarsel8029
@edwintmarsel8029 6 жыл бұрын
Excellent
@3CtrainingBD
@3CtrainingBD 4 жыл бұрын
nice
@PersianEngineer786
@PersianEngineer786 3 жыл бұрын
Thanks
@AnathEma64
@AnathEma64 6 жыл бұрын
Hi, Thank you for posting this. Could you please post a video of Seismic for a multi story building and one of wind loads. Thank yiu
@carloscm1323
@carloscm1323 4 жыл бұрын
Beautiful calculator
PE Seismic Review: How to Calculate Chord and Collector Forces
19:31
Enceinte et en Bazard: Les Chroniques du Nettoyage ! 🚽✨
00:21
Two More French
Рет қаралды 42 МЛН
VIP ACCESS
00:47
Natan por Aí
Рет қаралды 30 МЛН
So Cute 🥰 who is better?
00:15
dednahype
Рет қаралды 19 МЛН
Seismic Analysis of Multi-Story Buildings using the Response Spectrum Method
27:34
Dr Nafie - Structural Engineering
Рет қаралды 67 М.
SA52: Frame Analysis under Wind Load (Airplane Hangar)
12:37
Dr. Structure
Рет қаралды 94 М.
We make a snow garage - will it stay warm?
12:02
Garage 54
Рет қаралды 2 М.
Seismic Load calculation Part 1 As per IS:1893-2002 | Civil Engineering
25:10
Faulty Ubiquiti POE Network Switch | Can I Fix It?
31:22
Buy it Fix it
Рет қаралды 2,7 М.
Seismic Analysis Lecture #3 - Dirk Bondy, S.E.
44:50
Dirk Bondy
Рет қаралды 24 М.
Enceinte et en Bazard: Les Chroniques du Nettoyage ! 🚽✨
00:21
Two More French
Рет қаралды 42 МЛН