Purchased the hole punch and the AC plug just now! Thanks so much for your incredible videos! I've learned so much from you over the years!
@MrDoneboy Жыл бұрын
Cool Mark. You got it right next to your 2246 Tek on the bench!
@Mac-t4y Жыл бұрын
I would use the crimp connector with heat shrink activated adhesive seals for wire connection point instead of soldering.
@marcseclecticstuff9497 Жыл бұрын
A good source for cheap snap-in sockets like that is outlet strips. Many of the long box type outlet strips use these types of sockets. These Sencore units have gotten stupid expensive. Wish I would have bought a bunch when they were going for a couple of hundred....
@Rhine_Labs Жыл бұрын
Great Idea, Just got a 2nd one that would be worthy of this mod.
@andydelle4509 Жыл бұрын
Another note when using a chassis punch. The metal on the edge of the hole deforms slightly in the direction of the cutter part. In this example here, the cutter was pulled from inside the chassis to the outside, so there is a slight lip on the back. This may or may not be an issue but keep this in mind. To complicate this further, on a painted surface the cutter side is likely to chip paint around the hole. So again in this example pulling the cutter from the inside is less likely to chip the paint on the back panel. I must have punched thousands of holes with these punches in my 50 years of electronics. Both as a hobbyist and a professional..
@MichaelLowe-g7y11 ай бұрын
I was thinking about the use of this unit, and using an isolation transformer on the bench.... I know a usb connection defeats the isolation, but it occurred to me that using a signal generator does the same thing... So the scope is grounded to mains, and the DUT is isolated with an isolation transformer... Dummy load is isolated, BUT if you use a sig gen, doesn't that defeat the isolation? How do you use your sig gen with the isolation transformer on your bench Mark?
@tracyenglish9998 Жыл бұрын
Good morning Mark :)
@cajuncoinhunter Жыл бұрын
Awesome mod , where did you get those good looking shelf bracket / feet from ??
@cajuncoinhunter Жыл бұрын
Never mind that , I saw your video on it , I'll try to find some , I used to own a cabinet shop , so putting a custom shelf unit is no big deal for me ...
@MrMersh-ts7jl Жыл бұрын
So are you just adding a mains plug on the rear? That's what I gathered from the power strip comment. You're tapping in between the mains and the variac?
@MrMersh-ts7jl Жыл бұрын
Never mind, I went back and watched the other variac video and saw that the outlet is controlled with the front dial. Nice work
@Blueglow Жыл бұрын
Yes, simple mod so that I can feed a power strip out the back of the unit on the bench and not use the front plug that wears out over time.
@W3KW Жыл бұрын
Wow. You got lucky. I paid $1100 for mine which looked like it was never out of the box. Alas, the seller claimed to be great at packing...not so much. One layer of cheap bubble wrap and zero protection from the plug and yup, the case was all messed up on delivery. Such a shame.
@fullwaverecked Жыл бұрын
Nice SenCORE! He he...
@peteb2 Жыл бұрын
For the added rear outlet i'd have grabbed my stash of crimp spade terminals plus the crimp tool & put one on each lead then just a push-on at the outlet socket.... just saying.
@Blueglow Жыл бұрын
I'm not a fan of crimp anything, might let you down over time. But might not...
@andydelle4509 Жыл бұрын
I know what you mean. anything over 5 amps of current, you are asking to trouble after a few years. I still use them but keep this in mind for high current applications. @@Blueglow
@duanethompson2360 Жыл бұрын
If you know of anyone on the west coast looking for a lab, I’ve been trying to give mine away as I can no longer work. I live in La Grande Oregon. Full tube lab, tubes, amps etc. thanks Duane
@cajuncoinhunter Жыл бұрын
I sure could use a piece or 2 of what you have ....... HP RF signal generator 8656 or similar a variac etc...