Very useful video but apne P2000 bare me nhi bataya
@mallikarjunm4377 Жыл бұрын
Excellent and I want how to commission of drive through starter software
@rvelectricalguide Жыл бұрын
Thanks for the comment, I will upload video on it soon.
@mdnizamuddinansari79117 ай бұрын
Helo sir
@satyadevpal3268 Жыл бұрын
Delta vfd c2000 ka vedio banay sir
@rvelectricalguide Жыл бұрын
Abhi to mere paas Delta ka vfd nahi hai, jaub hoga to video upload kar denge
@debabratasahoo67005 ай бұрын
Sir , Analog current output to plc (4-20mA) parramitter setting Kiya hai?
@ashishjain358810 ай бұрын
F1662 fault in Siemens Sinamics PM 240 ..please help
@letsfun8 Жыл бұрын
Bhai ji mujhe simens g 120 ko do mode me chalana hai...D0 high krne per 0-10volt reference and D0+D1 high krne per fixed speed per chalani h
@rvelectricalguide Жыл бұрын
Jaise hi mere pass G120 vfd available ho jaega, aapko video ke jariye bata denge
@arunkumarbuchupalli28114 ай бұрын
P0311 how to check
@rvelectricalguide4 ай бұрын
In this video we have told how to check P03 11
@manikantarachuri1097 Жыл бұрын
how you fix ramp up 9 sec ,is there any calculations for 9 sec ?
@rvelectricalguide Жыл бұрын
There is no any calculation,You can set as per your requirement.
@DaljitChauhan-sp2uy Жыл бұрын
Sir hand aur auto mode me kya difference hota hai
@rvelectricalguide Жыл бұрын
Hand mode me drive auto me start stop nahi hoga, kewal vfd ke display se start stop hoga . Auto mode me vfd ke display se start stop nahi hoga, kewal auto me start stop hoga jaise HMI display, remote controll
@realme5i3943 ай бұрын
P322 Aur P1032 Same he hai kya
@rvelectricalguide3 ай бұрын
same nahi hai
@sushil49589 ай бұрын
Siemens Pm240-2 me start command ka parameter kon sa hai
@rvelectricalguide9 ай бұрын
P0015 - Macro drive unit select( 2-wire 1) set 17
@ritikkamdi41427 ай бұрын
Di/Do to batao (r722.0.....)
@ngocson3443Ай бұрын
Hi sir, please help me, F7802 😢
@rvelectricalguideАй бұрын
First of all check the input ,supply and tell me
@rvelectricalguideАй бұрын
if there is coming proper voltage 415 volt, both three phase, then there is a internal problem in power module(I think IGBT has been damaged) please check the internal terminal of power module with multimeter
@yogeshkumarmalik804 Жыл бұрын
From BOP to BOP per video digye
@rvelectricalguide Жыл бұрын
Ok, I will try to upload a video on it soon.
@hiteshparmar_131110 ай бұрын
Sir p10 parameter 0 karne ke bad me power of karke on karne pe p10 1 ho jata hai.
@rvelectricalguide10 ай бұрын
Iske liye aap ko ek settings karna hai, P10 pe 0 set karne ke baad, EXTRAS me jake OK presh karke , DOWN key ek baar presh karne par RAM to ROM likh kar aaega, uspe 2 baar OK presh karna hai, waha per busy likh kar aaega khuch der intijar karne ke baad, ESC key ko presh karte huwe back chale aana hai.
@rvelectricalguide10 ай бұрын
Iske baad drive ko off or on karke cheak kariye. Agar sahi hota hai to ,ek baar jarur bataiyega haumko
@hiteshparmar_131110 ай бұрын
@@rvelectricalguide ok
@hiteshparmar_131110 ай бұрын
Ok it's working ok thank you.
@rvelectricalguide10 ай бұрын
You welcome
@hiteshparmar_131110 ай бұрын
P310 me 50 hz set karte hai to 30hz running dikhata hai. And 60 hz pe 60 hz running dikhata hai. Konsa parameters check kare
@rvelectricalguide10 ай бұрын
Cheak P0322 Maximum Motor speed kitna hai?
@hiteshparmar_131110 ай бұрын
Solve this problem thank you
@realme5i394 Жыл бұрын
Sir parameter download kaise kare kisse bhee drive ka please help me
@rvelectricalguide Жыл бұрын
Aap apne drive ka moddel number or Company name bhejiye, may aap ko link bhej dunga
@realme5i394 Жыл бұрын
@@rvelectricalguide 6sl3210 1pe18 oul1
@yogeshkumarmalik804 Жыл бұрын
Display per cross ka Symbol ring m show ker raha hai ye kya hai
@rvelectricalguide Жыл бұрын
Cross means If any fault is found, the inverter will be shut down and the user It is necessary to take necessary corrective action to clean it up. The situation is that the inverter will not shut down. For example, high temperature.
@budhanandgaikwad12329 ай бұрын
Fault F7801 pz help
@rvelectricalguide9 ай бұрын
Cheak P305 Rated motor current? P640 current limit? P1120 Ramp up time? And also check the motor resistance by multimeter
@badalraj67479 ай бұрын
Sab sahi aata hai but phir bhi trip ho raha hai
@badalraj67479 ай бұрын
Motor kW 75 rpm 1450,ampr 132, or parameters 640 me 155 ampr hai
@rvelectricalguide9 ай бұрын
Ramp up time or ramp down time kitna hai?
@pappukushwaha977511 ай бұрын
Pura parameters aata hai
@rvelectricalguide11 ай бұрын
Kaun sa parameter ka jankari lena chahte hai?
@unnikrishnan61114 ай бұрын
Is there any option to see the only the parameters, its value changed from its default value.
@rvelectricalguide4 ай бұрын
For default value you see in manual parameter
@DaljitChauhan-sp2uy Жыл бұрын
Sir apka no. Mil skta ha
@nasirshahab7669 Жыл бұрын
Siemens g120 vfd cooling fan set temperature parameter bataein.
@rvelectricalguide Жыл бұрын
Parameter number p0295 par Jakar set kar sakte hai