I really thank you so much for making this video for further study, but I apologize for the inconvenience in this show, I really do not like to put the flexible join on over there, because we can not turn off the water from the discharger from the delivery pipe when there is a problem with this flexible. thank you !
@GemmyHeart Жыл бұрын
Main products: sealing gasket,gland packing,PTFE/graphite/asbestos products, ceramic fiber products, high temperature heat insulation and fireproof material. Free technical support (sealing, heat preservation, heat insulation, fire prevention problems) All products 1 piece can also be customized, 30 years of service experience, fast and safe shipping anywhere.
@DDDelgado Жыл бұрын
@5:30 expansion joint, great idea, we have a pump that normally realign 😮
@rezashahzadi95416 жыл бұрын
thanks for the informative data. would anybody explain about slope of the pipe at suction area for transfering fluid from lower height and from tank to avoid air pocket formation.
@orac2292 жыл бұрын
All our pumps in our timber treatment plant have oneway valves fitted, are they really necessary? Are they better on the inflow or outflow of a pump?
@Murag_engineers5 жыл бұрын
Why you are not using flexible joint at suction line?
@rodglaisher91292 жыл бұрын
Interesting no mention of checking for pipe strain induced stress on the pump casing or electric motor soft foot. Both big contributors to vibration.
@hs-salahudinsyah82855 жыл бұрын
great information that released as well
@SohilShah_Melodyman8 жыл бұрын
Very informative!!Thnx a lot!
@MTA1414 жыл бұрын
I have a question: Why eccentric reducer can make avoid air pocket formation? Thanks a lot
@jatinsharma37924 жыл бұрын
great explanation
@salomon65703 жыл бұрын
Buen día, una consulta. ¿Cuáles serían la consecuencia en la bomba, si la reducción excéntrica la parte recta la pongo hacia abajo? Teniendo en consideración que sea de succión positiva.
@abderrahmaneboubendir1312 жыл бұрын
What do you mean by water hammering
@FrancisTakai-sz6ro2 ай бұрын
Hi. I would like to know more about the proper installation. I am trying to installation 600kl water tank. From the base, lower elevation I be having a 47kl tank. I'll email the design site information once upon your response. Thank you
@stalone779 жыл бұрын
Buen video, quisiera saber con que programa se realizo este video.
@thaeralshamary53402 жыл бұрын
Thanks alot
@Praveen2715 жыл бұрын
Good one..!!
@بوفارسبونورا-ص7ه5 жыл бұрын
How check valve prevent water hummer ? Ckeck valve creates water hummer .
@redakounbi71445 жыл бұрын
check valve prevents the back flow of relatively high pressurized liquid to the pump in the discharge line so that the impellers stay safe .
@eng.omeralfaroug16475 жыл бұрын
مع اني لم أشاهد الفيديو حتي الآن ولكن محبس عدم الرجوع يحمي المضخة من الهامر وذلك بمنع رجوع هذة الصدمات إليه في حالة توقف الحركة فجاءة او إنقطاع الكهرباء وبذلك يمنع رجوع هذة الصدمة الي ريشة المضخة وشكراً
@m.almarzuqi73674 жыл бұрын
Nice background music 😂
@arkreaktor41247 жыл бұрын
nice video
@maomengtan34575 жыл бұрын
Very good
@TheRealFOSFOR7 жыл бұрын
Still don't get it why the eccentric reducer has to be "upside down"? See this all the time... now even in this video. You would think that the reducer should go with the slope. Not against it.
@TheRealFOSFOR7 жыл бұрын
At 2:40 it could/should be upside down in my opinion.
@al1517 жыл бұрын
The purpose of the eccentric reducer for being upside down is to prevent trapped air. Lets assume you put the reducer slope section up, now put a straight line following the upstream flow pipe diameter. That triangle space above the reducer will trap air and other gasses and creates bubbles in the liquid. You are pretty much disturbing the flow. On a centrifugal pump, the last thing you want to have is bubbles on the suction side eye socket. Those bubbles will burst on the impeller vains with supersonic velocities causing damage to the impeller. This is called cavitation.
@TheRealFOSFOR7 жыл бұрын
So the fact that the pipe is at an upward angle doesn't let air escape? Well.. I guess not if there is nowhere for the air to escape to x) unless there is a bleeder valve of some sort I suppose.
@al1517 жыл бұрын
You always assume even with the incline the pipe is full of liquid all the way to the inside diameter wall. Bleeder valves are typically used if you are dealing with hot liquids and heatexchanger piping. Honestly I don't see any reason not to use a bleeder valve on the suction side of any pump piping.
@mylapallimahesh30096 жыл бұрын
Super
@محمدشاهين-ح4ل7 жыл бұрын
@Mohamed abdelrazak
@shepherdshour9794 Жыл бұрын
Ok
@manowar85167 жыл бұрын
nice
@jovitocastueras98396 ай бұрын
Maximun head of 2hp
@mo3azsoliman4362 жыл бұрын
ارجو اضافة ترجمة بالعربي
@davidmorgan29805 жыл бұрын
The music is awful and way too loud. Just kill the music.