Single Line Diagram for 132/11KV Substation || Most asked Interview Question in Electrical ||

  Рет қаралды 107,451

RAJ TUTORIAL HINDI

4 жыл бұрын

In this video I have explained how to draw single line diagram in electrical for 132/11 kv substation.So watch my video to know.
Thanksss
#SLD #single_line_diagram #rajtutorial

Пікірлер: 50
@reshamkhan4141
@reshamkhan4141 3 жыл бұрын
Phli baar SLD Maine samjha sir bhut hi easy way me....thnks for valuable information 👍...keep it up😊... please make more vedios related SLD ...
@waseemazizi9401
@waseemazizi9401 Жыл бұрын
Excellent informative video. . I like it for myself and others.
@MeezanConsultancy
@MeezanConsultancy 2 жыл бұрын
Such a wonderful explaining skills
@prashanthkumar7805
@prashanthkumar7805 3 жыл бұрын
The way you cxplained is very good and it's clear
@ShubhamYadav-dj1cy
@ShubhamYadav-dj1cy Жыл бұрын
Impressive & easy way to learn to you sir ❤️
@user-mrmad
@user-mrmad 9 ай бұрын
Bro I think Line Isolator one required before CT and after CT first we required CB for over current relay tripping to command CB Trip and than Isolator and than transformer LA..
@kusheegammingchanal9048
@kusheegammingchanal9048 Жыл бұрын
Sir good and worthy vedio for SLD
@roshankatle485
@roshankatle485 3 жыл бұрын
sir app please substation ke sath equipment ke (ct, pT, isolator , tranformer , lighting arrester , bracker , ) technical specification jaise rating/ capacity bhi batao. please.
@bleesaqeebibneHussain
@bleesaqeebibneHussain Ай бұрын
Thak u soo much sir
@maneeshkumar341
@maneeshkumar341 3 жыл бұрын
Thanks sir
@gangadeenyadav4745
@gangadeenyadav4745 Жыл бұрын
Good 👍
@RATANKUMAR-tr5xt
@RATANKUMAR-tr5xt 10 ай бұрын
❤❤❤❤ super ❤️💓💓💓💓💓
@simpleandeasy7289
@simpleandeasy7289 3 жыл бұрын
Please explain Single line diagram of gas insulation substation
@SHAILESH98523
@SHAILESH98523 Жыл бұрын
Nice
@ajaysingh-India2023
@ajaysingh-India2023 3 жыл бұрын
Pt is replaced by CVT , after wave trap then ct ok.
@SameerKhan-ty9lr
@SameerKhan-ty9lr 3 жыл бұрын
Sir DG ka bhi SLD ka video bhi banaye
@afrozalam6390
@afrozalam6390 3 жыл бұрын
How to load transfer sir please tell about it.
@SanjayGupta-mv4xe
@SanjayGupta-mv4xe 2 жыл бұрын
Sir. Busbar me isolater then sf6 hoga ki isolater ct. Then sf6
@sitanshukumarjena4648
@sitanshukumarjena4648 3 жыл бұрын
Busbar k baad Isolator then Circuit Breaker then CT then LA ho kr PTR k sath connect hota hai. Incomer k time CT & Ckt Breaker rahega then iska opposite bus bar k baad rahega means first Ckt Breaker and CT
@AdnanKhan-yn6ic
@AdnanKhan-yn6ic Жыл бұрын
What's the technical issue in this brother?
@rajnarayannishad6437
@rajnarayannishad6437 Жыл бұрын
Lajvab veadio
@shekharsoni4148
@shekharsoni4148 3 жыл бұрын
Bus bar use karke apne bane bahut sare break points bana diye hain isse kaafi losses honge line me
@anilkumarmehta1923
@anilkumarmehta1923 2 жыл бұрын
You have explained nicely. Only avoid to say VCB for 132 kv system. VCB is available only upto 33kv.
@AdnanKhan-yn6ic
@AdnanKhan-yn6ic Жыл бұрын
What they will use instead of vcb ?
@anilkumarmehta1923
@anilkumarmehta1923 Жыл бұрын
@@AdnanKhan-yn6ic SF6 ckt breaker
@AdnanKhan-yn6ic
@AdnanKhan-yn6ic Жыл бұрын
@@anilkumarmehta1923 this breaker use upto which
@shekharsoni4148
@shekharsoni4148 3 жыл бұрын
Feeder me jane se pehle air circuit breaker ya vacuum breaker lagana padega
@parthabiswas8330
@parthabiswas8330 3 жыл бұрын
Gis substation ma jaruri nahi hai
@rahulpndit9003
@rahulpndit9003 Ай бұрын
CT k before isolator hota h
@Mohsinkhan-kv3zl
@Mohsinkhan-kv3zl 2 жыл бұрын
Can you show me the sld for 11kv to 440v
@rohtashrohtash9129
@rohtashrohtash9129 22 күн бұрын
CT se pahle isolator aata h sir
@rishabh7054
@rishabh7054 Жыл бұрын
Plz making SLD 132/6.9kV that belongs to my plant .
@PINKUKUMAR-wg7uo
@PINKUKUMAR-wg7uo Жыл бұрын
Isalotar aur Circuit breaker ek ko bolte hai
@chooper3048
@chooper3048 Жыл бұрын
do u have english version sir
@indranathmoulick4915
@indranathmoulick4915 3 жыл бұрын
At the Incoming side (after LA) how can we turn off the power of the next CT / PT is to be replaced. There should be an Isolator. Please confirm as per actual
@apc2729
@apc2729 2 жыл бұрын
That's is your sf6 circuit breaker and isolator
@deepakSingh-wb5vt
@deepakSingh-wb5vt 2 жыл бұрын
Sir CT PT cumbid kha gi
@purusottamkanta69
@purusottamkanta69 2 жыл бұрын
Bhai incoming mein cvt or pt
@FZ-NF2030
@FZ-NF2030 10 ай бұрын
132kV Busbar - Isolator/Earth Switch - CT - Braker - VT - LA - Power Tranformer
@akhileshshyamkuwar4223
@akhileshshyamkuwar4223 2 жыл бұрын
Sir samjte hui photo dikhwao
@sahilkool420
@sahilkool420 Жыл бұрын
ISME CVT KYU NHI LAGAAYA AAPNE. 100KV KE UPAR CVT LAGANA HOTA HAU
@SumitKumar-pf9gr
@SumitKumar-pf9gr 3 жыл бұрын
What about earthing switch in SLD??
@apc2729
@apc2729 2 жыл бұрын
Earthing switch ? What is that about?
@arjunmohurle
@arjunmohurle Жыл бұрын
This question asked to me by panelist
@praveenacharya1582
@praveenacharya1582 Жыл бұрын
Where is disconnector?
@nadim9473
@nadim9473 3 жыл бұрын
Par ye circuit breaker do Baar q lagaya Gaya
@chandrashekharprajapat7646
@chandrashekharprajapat7646 3 жыл бұрын
Men लाइन का
@jitendrasingh9916
@jitendrasingh9916 5 ай бұрын
sir transformer ke parallel me PT install nhi kiya aap ne ...glat he aap ka wiring digram
@muhammadinam-rk7jo
@muhammadinam-rk7jo 19 күн бұрын
Rubbish make SLD