At 3:40 you said Low Voltage winding is short circuited by thick conductor but In digram you did for High Voltage Winding
@bereketmolla44536 жыл бұрын
wow that is classic sir
@EzEdChannel6 жыл бұрын
Thank You +bereket molla. Please subscribe to our EzEd Channel for more such videos.
@godfreyghatt44602 жыл бұрын
in the formula for maximum efficiency you used the parameter x without defining it
@navneetkumarsabre72756 жыл бұрын
Your lecture is awesome.you done a great job Keep up the good work .. But there is a very small error u made in ciruit diagram.. In short circuit test of transformer you shorted the H. V. side instead of L. V. (But you speak that part correctly )... 😊😊
@EzEdChannel6 жыл бұрын
Thank you +NAVNEET SABRE. We will look into the issue that you mentioned. Please subscribe to our EzEd channel for more such videos.
@labulitiolle6 жыл бұрын
Where do the values 25 and 0,8 come from in you expression at 7:55 ?
@EzEdChannel6 жыл бұрын
Hi @labulitiolle , please find the updated solution on this link kzbin.info/www/bejne/j6GzqHqNm8SIfdk
@mrgopi41813 жыл бұрын
I think problem is different, solution is different
@anthonystehr79194 жыл бұрын
When moving Z from secondary to primary, its Zs' = Zs(a^2), not divided by a^2
@EzEdChannel4 жыл бұрын
Hello Anthony, please let me know the time in the video that you are referring to. That will help us reply to you earlier.
@vishnubollineni7 жыл бұрын
How do u got o/p voltage while calculating full load efficiency
@EzEdChannel7 жыл бұрын
Could you specify the time on the video where you have this question?
@aishwaryasrivastava39985 жыл бұрын
EzEd Channel at 7:55 plzz tell how you get the output voltage while calculating full load efficiency u used the formal as told by u but how u put the value 1×25×0.8
@deepansharekere44864 жыл бұрын
4:08 shouldn't it be core loss
@cablegy8683 жыл бұрын
you are right, its core loss
@robinmaikle92125 жыл бұрын
Are your teachers busy? Discover: androidcircuitsolver/app.html