Size Of Plinth Beam 1 to 4 Storey Building ||

  Рет қаралды 514,724

Civil Engineer Dishant

Civil Engineer Dishant

Күн бұрын

Пікірлер: 86
@gopalnayall5328
@gopalnayall5328 Жыл бұрын
Yaha par ek mistake yah hai , jaha par sariya samapt ho raha hai . Vah 90 degree par band nahi ho raha hai . Usme huk nahi bana hai .
@deepakkk2360
@deepakkk2360 9 ай бұрын
Right
@user-fj9uj9mo6d
@user-fj9uj9mo6d 6 ай бұрын
Ya i have noted
@Rajuvermashorts
@Rajuvermashorts Ай бұрын
Correct
@gopalagrawal2326
@gopalagrawal2326 9 ай бұрын
Plinth beam size has no connection with no of storeys being built because beam at each storey is designed as per storey load on the beam. The beam size also depends on span and end condition of beam but not on storeys being built. Do not give wrong information. You do not seem to be a civil engineer.
@user-so3mi7oi9y
@user-so3mi7oi9y Ай бұрын
Right sir.
@ashokkumaryadav6477
@ashokkumaryadav6477 Жыл бұрын
Dear plinth beam depend on column to column distance or no of floor clear it.
@RohitGamingsbp
@RohitGamingsbp Жыл бұрын
Sir 12.6 feet me hai ek column se dusra column distance h to me kitna rakhu 9*12ka h column 6bar wali reply sir please
@kanhucharanmurmu2863
@kanhucharanmurmu2863 Жыл бұрын
My dear, plinth beam & column are integrated part of a house construction. Don't you think the reinforcement of plinth beam and column will have to go parallely ? I mean can i use 8 dia rod for column while 16 dia in plinth beam? And what must be the column size wher I have 9'* 12' plinth beam? Is the column of 9' * 9' with 12dia rod ok? So, please avoid to give incomplete information . You are a responsible Engineer........
@DineshBhonde
@DineshBhonde Жыл бұрын
Kaha padhe ho engineer bhaiyya? khudko engineer bolte ho AUR civil engineering bilkul pata nahi. Viwers and the engineer bhaiyya please note following points. 1. The plinth beam size does not depend on number of storeys. 2. Beam size depends on load on it and end conditions. In case of plinth beam the load on the plinth beam is from the walls up to slab beam. 3. The end moments and the mid span moment is calculated from load and the end conditions using various structural analysis methods or software like STAAD. 4. Required concrete section and steel is provided. THE INFORMATION GIVEN IN THE VIDEO IS COMPLETELY MISLEADING AND MAY CAUSE DISASTER. Get structural design from the structural engineer instead of following such videos.
@abvlog8857
@abvlog8857 12 күн бұрын
G +1 building par 9 inch ka red bricks ka wall de sakta hu na. Ya beam aur majboot karna parega 9 inch wall ke liya
@hariprasad6573
@hariprasad6573 Жыл бұрын
Is plinth beam dependent on the soil? Which size of plinth beam may be suitable for black cotton soil?
@shyamaprosadadhikari8631
@shyamaprosadadhikari8631 Жыл бұрын
No. That depends on columns load as well moment.
@hariprasad6573
@hariprasad6573 Жыл бұрын
Thank you for information.
@prakashvidyarthi4903
@prakashvidyarthi4903 Жыл бұрын
Actually it ground beam not plinth beam, secondly size n reinforcements depend upon span of beam n load to be carried out on it and type of beam column connection.
@chennareddyindla2349
@chennareddyindla2349 Жыл бұрын
Good
@abidmahmood9097
@abidmahmood9097 Жыл бұрын
Mostly guideline are given about the Plinth Beam, but no guidelines are given about the Columns in the Foundations, Where as Plinth Beam is useless without these columns.
@ajayrajput-fh5ze
@ajayrajput-fh5ze 10 ай бұрын
. mostly column and beam are would be same
@Allup11
@Allup11 9 ай бұрын
Plinth beam rod and column rod size Kiya same hona parega,
@NRKhan-uo8yn
@NRKhan-uo8yn 9 ай бұрын
Sir ji G3 building ke beam main 16 mm 4 sariya 1 cut pies chalega kya? Please reply today
@arupupadhyay6037
@arupupadhyay6037 Жыл бұрын
Sir , 7 by 7 pillar pe 4 inch ka floor de sakte hai kya ?
@AGFUNHUB
@AGFUNHUB Жыл бұрын
Na
@aveonleo
@aveonleo Жыл бұрын
Video kai starting mai jo PB dia hai wo kitni story ka hai , , 3no. Top and 3 no. Bottom????
@kailashsony1520
@kailashsony1520 Жыл бұрын
क्या टाई बीम/प्लिंथ बीम में क्रैंक बार बीच में या टॉप एक्स्ट्रा दोनो एंड पर l/4 लंबाई की और बॉटम एक्स्ट्रा बार बीच में G+1/G+2or3..... में प्रोवाइड नही करेंगे ?
@sandeepdeshmukh9974
@sandeepdeshmukh9974 2 ай бұрын
Best information sir
@myubey
@myubey Жыл бұрын
End of beam look defective, no L in the rods, also no crank shaft present
@invincibleraah72
@invincibleraah72 Ай бұрын
Before civil engineer bhi ghar bante the na which was far better and efficient than their suggestions
@sharadkripal
@sharadkripal 29 күн бұрын
Thanks you sir
@umeshmore5598
@umeshmore5598 4 ай бұрын
सर मेरे घर का स्ट्रचर पुराना है . कुछ कलम 9।/15 हे. कुछ ९/१२ है ग्राउंड फॉर मे. फिर g+१ मे बीच के कलाम ९/१२ है और बाकी outer ९/९ . है। फिर g+२ बना रहा हु पर बार १२ mm का ही है. और उपर टोवर् भी है. क्या घर को कोई आगे जाके khatra तो नही होगा, और दो रूम बेसमेंट भी है
@himanshudiwan4086
@himanshudiwan4086 6 ай бұрын
Bhai hum ne aisa rakha hai 4 (12) k Or 2(10) k upar 3 niche 3 to kitne manjil tk ka bna sakte hai pilar me hai 16(4) or 12 k (2) btao bhai
@mohammedbahauddin5738
@mohammedbahauddin5738 Жыл бұрын
Plinth beam sirf pillor to pillor per dipende per hita hy na ky floor per aur Aap ko plan bhi galat hy piller span zayada hy per 6 rood 12 mm ky hy wahan perto 18 inch ka hona chiye Aur 16 mm 6 rood hona chahiye
@muhammadzuhaib534
@muhammadzuhaib534 10 ай бұрын
9 inches ki deevar me plinth beam lazmi hai kiya 2 storey building ke liye.
@thawardaskrishnani4393
@thawardaskrishnani4393 10 ай бұрын
❤Great video
@pisals
@pisals Жыл бұрын
please move camera slowley. we can not see and observe it properly
@milanoraon2236
@milanoraon2236 4 ай бұрын
Nice
@akhan8456
@akhan8456 3 ай бұрын
Why you take thumb rule and not specific building codes?
@radheshyamverma973
@radheshyamverma973 Жыл бұрын
G+ 20 का plinth bram के बारे में बतायें please
@3dcreativeindia422
@3dcreativeindia422 Жыл бұрын
kzbin.info/www/bejne/aqqTpaKGgrdjrc0
@babubadsha1480
@babubadsha1480 Жыл бұрын
Thanks for information
@NidhiErikshaTecnicalGuru
@NidhiErikshaTecnicalGuru Жыл бұрын
भाई हमारे यहां तो आज से मात्र 5 साल पहले बिना पिलर का मकान बनाया है 16 इंच की और 12 इंच की दीवाल है उसी पर हमने 4 माला पांच माला बना दिया है यह पिलर पिलर सब फिजूल का खर्चा बढ़ाता है और दिमागी टेंशन है
@cruiserider7263
@cruiserider7263 Жыл бұрын
Bhukamp se dar bhosorike
@SalaamHind
@SalaamHind Жыл бұрын
Sir roof beam ka Kiya steel details hoga 4 story
@kamrulzoha9223
@kamrulzoha9223 Жыл бұрын
Aap ne kahi bhi beam ko lap me bandha nahi hai ?? Bhai ye to galat hai
@rajendrasonkar2703
@rajendrasonkar2703 Жыл бұрын
Very good sir
@anujkm
@anujkm Жыл бұрын
Beam ki 5d (end kisariya moda kyu nhi h ap to engineering ho na
@SukhdevSingh-bs8ss
@SukhdevSingh-bs8ss 9 ай бұрын
Nice video Kuwait
@sheriff8258
@sheriff8258 Жыл бұрын
What about number of bars same as mentioned in video but with 9*9 beam
@saurabhkumarsingh1137
@saurabhkumarsingh1137 9 ай бұрын
Is plinth beem me 90° band nhi h kyu
@Singh-pq7tk
@Singh-pq7tk Жыл бұрын
Pilecap k pedestal se dena hota h plinth beam .
@Seema-sj8me
@Seema-sj8me Жыл бұрын
🇮🇳hello India group🇮🇳
@virnedrathakurvirnedrathak6308
@virnedrathakurvirnedrathak6308 Жыл бұрын
G+1 ka kalam BIM ke bare me batay
@binodmodi8340
@binodmodi8340 3 ай бұрын
Galat bol raha hai Load bearing me 2.5 Manjila Ghar bana dete hai Toh 9/9 piller me 2 manjila kaise nahi banega
@gouravmeenavlogs
@gouravmeenavlogs 2 жыл бұрын
Good 🙏
@CivilEngineerDishant
@CivilEngineerDishant 2 жыл бұрын
Thanks 🙏🙏🙏🙏🙏🙏😊😊😊
@ramraj12929
@ramraj12929 Жыл бұрын
9by12 sahi rahega sir resformrnt 3 bar upar 3 bar niche 12mm ka
@CivilEngineerDishant
@CivilEngineerDishant Жыл бұрын
Bottom me 16’mm rakhna hoga bhai tumko
@AmitKumar-jy4zd
@AmitKumar-jy4zd Жыл бұрын
9. By 12 kya hoga
@3dcreativeindia422
@3dcreativeindia422 Жыл бұрын
kzbin.info/www/bejne/aqqTpaKGgrdjrc0
@SunilKumhar-im6xz
@SunilKumhar-im6xz Жыл бұрын
L3 aur L4 ko kitna me bhagah karna hai
@devendrapratapsharma8355
@devendrapratapsharma8355 Жыл бұрын
Thanks
@vellay914
@vellay914 Жыл бұрын
U r really awesome 👍👍👍
@3dcreativeindia422
@3dcreativeindia422 Жыл бұрын
बहुत बढ़िया kzbin.info/www/bejne/aqqTpaKGgrdjrc0
@arvindpatil8260
@arvindpatil8260 10 ай бұрын
Guidelines don't work. Consult structural engineer
@homeplan3532
@homeplan3532 Жыл бұрын
l development nahi hai kya plinth beem mein
@prakashvidyarthi4903
@prakashvidyarthi4903 Жыл бұрын
Misguided information, do not follow it. It is not technical. Only blunder. Please remove it as soon as possible.
@3dcreativeindia422
@3dcreativeindia422 Жыл бұрын
kzbin.info/www/bejne/rYuTc4RumpureNk
@sureshsharmaph8140
@sureshsharmaph8140 Жыл бұрын
pliz dont move ur camera very fast ...
@MrEditz-yb6ws
@MrEditz-yb6ws Жыл бұрын
Sir G+1 ke liye wall beam ki size &bar ki size kya hona chahiye?
@dipalishakya3981
@dipalishakya3981 2 жыл бұрын
Bahut accha bhai
@SanjaySingh-gk8qk
@SanjaySingh-gk8qk Жыл бұрын
Speak fastly
@clintonfernandes3721
@clintonfernandes3721 Жыл бұрын
Ye video bas thekedaaro ko hai not for engineer's
@dineshpaikrao
@dineshpaikrao Жыл бұрын
Ye plinth beam nahi group level beam hai
@SSeveryThing12
@SSeveryThing12 Жыл бұрын
FINAL EXAMINATION (2022-2023) NAME : SHUBHAM KUMAR Adm No. MOTHER'S NAME : LAXMI DEVI FATHER'S NAME : BISHUN SAH Class: SIX B ROLL NO. 4 SUBJECT MAX. MARKS MARKS OBTAINED Total Theory Practical English 100 71 20 91 Maths 100 65 20 85 Hindi 100 50 20 70 Science 100 67 20 87 Social Studies 100 59 20 79 Computer/GK 100 68 20 88 AB: Absent in the Subject Marks Obt.500Max. Marks600Percentage83 %GradeA Position In Section :Attendance : / Grade Scale for Scholastic Areas Grade A+ A B+ B C D % Range 90 - 100 80 - 90 70 - 80 60 - 70 45 - 60 30 - 45 Class Teacher Remarks Date : 31/03/2023 Class Teacher's Signature Controller's Signature Principal's Signature
@GuruRajpoot6633
@GuruRajpoot6633 Жыл бұрын
ये क्या था भई😅😅😅😅😅
@arvindbamne7420
@arvindbamne7420 Жыл бұрын
Bim k baar me al to lagay hi nahi
@3dcreativeindia422
@3dcreativeindia422 Жыл бұрын
kzbin.info/www/bejne/aqqTpaKGgrdjrc0
@dhirunand
@dhirunand Жыл бұрын
2:33 full bakwas
@dipakgref
@dipakgref Жыл бұрын
Plinth beam me crank ka required hai ki nehi
@shyamagarwal4215
@shyamagarwal4215 Жыл бұрын
Big mistake here The beam rod ends are not in bend L shape This is must for earthquake Protection
@Bankura12345
@Bankura12345 Жыл бұрын
Rod binding big mistake no L here
@paragkeot0077
@paragkeot0077 Жыл бұрын
Mera g+2 16mm 6 piece
@radheshyamverma973
@radheshyamverma973 Жыл бұрын
Totally wrong , sir
@TKM_FILEX
@TKM_FILEX 9 ай бұрын
Wrong information
@Vision_Of_Realities
@Vision_Of_Realities 3 ай бұрын
Lowest level of construction 👎
@dhanpalsargada6280
@dhanpalsargada6280 Жыл бұрын
Nice
5 Important Rules of Beam Design Details | RCC Beam | Green House Construction
8:45
NHÀ XANH VIỆT NAM
Рет қаралды 2,1 МЛН
Bend The Impossible Bar Win $1,000
00:57
Stokes Twins
Рет қаралды 40 МЛН
АЗАРТНИК 4 |СЕЗОН 1 Серия
40:47
Inter Production
Рет қаралды 1,2 МЛН
Cute kitty gadgets 💛
00:24
TheSoul Music Family
Рет қаралды 21 МЛН
Structural Shapes Ranked and Reviewed - Which one Wins?
15:34
The Engineering Hub
Рет қаралды 690 М.
Maximum distance between two columns | Column size and steel details for G, G+1, G+2, G+3 | column
5:21
Basic Rules for Lapping length in Beam - Lap length in RCC Beam || By CivilGuruji
8:18
Civil Engineers Training Institute
Рет қаралды 833 М.
What is Foundation | Types of Foundation | Types of Footing | Column foundation
6:59
Civiconcepts - Bhushan Mahajan
Рет қаралды 2 МЛН
Does Rebar Rust?
7:49
Practical Engineering
Рет қаралды 4,6 МЛН
Check list and Reinforcement details for PLINTH BEAM
13:58
Civil Help
Рет қаралды 158 М.
Ground beam
3:30
Site Engineer
Рет қаралды 60 М.
Bend The Impossible Bar Win $1,000
00:57
Stokes Twins
Рет қаралды 40 МЛН