Small Engine Generator Q and A with James Condon and Gary Bernacki LIVE February 21st at 9pm EST

  Рет қаралды 4,150

Ken’s Small Engine Repair - Mr. Mow It All

Ken’s Small Engine Repair - Mr. Mow It All

Күн бұрын

Пікірлер: 45
@robertsimpson7113
@robertsimpson7113 3 ай бұрын
The oil questions always slay me!!! Multi grade oil is just that !!! 5W30 is thinner when cold than 10W30 is but the same when hot. So would you rather be pushing peanut butter through a cold somewhat dry engine or something thinner that will get there much sooner? I personally use synthetic 5W50 in everything but snowblowers because the 5W30 is fine for the cold climate....... I.M.O. NEVER had any engine issues! My generator is a 1997 Honda EM5000, my garden tractor & snowblower are 1998 and my push mower is 1986. All run beautifully and start effortlessly, and always shut off the fuel and run the carb dry after every use and Ethanol Free fuel!!!!!!!
@Dan_Canuck
@Dan_Canuck 10 ай бұрын
You hit at least 167 watching that stream. 👍
@KensSmallEngineRepair
@KensSmallEngineRepair 10 ай бұрын
Yes, very successful, thanks to all for watching and participating, liking, and subscribing!
@mattyal9347
@mattyal9347 22 күн бұрын
I should be taking notes.
@GTOUTUBE
@GTOUTUBE 10 ай бұрын
Thank you, the intake valve has a valve seal, the exhaust valve doesn't have one, no place for it. The exhaust valve does have .006 play in the guide. The engine is a Briggs 19G412-1129E1 you guys are fantastic.
@robertdavis6708
@robertdavis6708 7 ай бұрын
I follow James weekly but not Ken And Gary. I'll be looking for their channels daily. These fellas know their S#%t.
@KensSmallEngineRepair
@KensSmallEngineRepair 7 ай бұрын
Thanks for watching!
@drunkingsailor2359
@drunkingsailor2359 10 ай бұрын
Great show guys. Stay the course steady as she goes.
@KensSmallEngineRepair
@KensSmallEngineRepair 10 ай бұрын
Thanks for watching!
@johnglynne9032
@johnglynne9032 10 ай бұрын
Sorry I missed your show live but better late than never!! It is always good learning new things through your discussions. Thanks again for sharing your knowledge!! Regards, John
@KensSmallEngineRepair
@KensSmallEngineRepair 10 ай бұрын
Saturday’s Live will focus on tech for the first 30 to 60 Minutes
@rickthelian2215
@rickthelian2215 10 ай бұрын
Missed the live watching replay😊
@KensSmallEngineRepair
@KensSmallEngineRepair 10 ай бұрын
It was one of our best!
@mickwolf1077
@mickwolf1077 10 ай бұрын
I had to work and watched after but watching now
@KensSmallEngineRepair
@KensSmallEngineRepair 10 ай бұрын
Thanks for watching!
@demetriosa7646
@demetriosa7646 9 ай бұрын
I have a standard Predator 9000 generator. Both my furnace and Ac have in line MARS surge protectors. Will this help in anyway from the dirty electricity. I have been using my generator with no issues. Most other electronics are in power strips that have surge protectors. Any insight on this?
@Bassguitarist1985
@Bassguitarist1985 9 ай бұрын
No they will not protect against dirty power, AKA high total harmonic distortion. Surge protection is better than none at all. It won't prevent malfunction which is a higher chance than with an inverter generator.
@CaliRootstoTennesseeBoots
@CaliRootstoTennesseeBoots 3 ай бұрын
Great conversation on Thd. Just what I needed to hear though it's a disappointment. I bought a used Firman tri fuel 7500/9000 generator barely used for $500. Starts and runs great but I read the Thd is 11-14%. I'm wondering now if I can even use it for my digital controlled Mig welder. I really got it for rare brown outs during summer. Wanted to run lights, TV, refrigerators. Now I know I can't. It's a beautiful machine but turns out not much I can use it on. On another note, someone asked how you all got started in your sidelines. I'd like to know what kind of work is your day jobs?
@KensSmallEngineRepair
@KensSmallEngineRepair 3 ай бұрын
I’m a machine repair foreman
@davidbell7066
@davidbell7066 9 ай бұрын
Impressive very helpfully
@berthongo8531
@berthongo8531 10 ай бұрын
Great show!
@KensSmallEngineRepair
@KensSmallEngineRepair 10 ай бұрын
It went by fast! Good content!
@fayiznalu8411
@fayiznalu8411 10 ай бұрын
Good tips 👍
@fayiznalu8411
@fayiznalu8411 10 ай бұрын
Hello everyone 🤗
@KensSmallEngineRepair
@KensSmallEngineRepair 10 ай бұрын
Good day to you!
@argonthesad
@argonthesad 6 ай бұрын
My lawnmower won't start. I need help urgently!
@KensSmallEngineRepair
@KensSmallEngineRepair 6 ай бұрын
Symptoms? Make and model?
@dnrsmallenginerepair
@dnrsmallenginerepair 10 ай бұрын
sorry i missed this one my friend your awesome you know your stuff.
@KensSmallEngineRepair
@KensSmallEngineRepair 10 ай бұрын
We had a good time!
@robertsimpson7113
@robertsimpson7113 3 ай бұрын
James; What is your day job??
@KensSmallEngineRepair
@KensSmallEngineRepair 2 ай бұрын
I’ll step in here, James is IT and Gary is in Logistics
@GTOUTUBE
@GTOUTUBE 10 ай бұрын
How do I know if my Generac 5,000kw is pulling a load with nothing plugged in. Can't seem to get rpm's up. I don't have a tach, also it smokes a lot when first starting up but stops when warmed up. Valves have been lapped.
@Bassguitarist1985
@Bassguitarist1985 10 ай бұрын
Grab a tach, the engine will noticeably drop in speed when loaded. Smoking a lot at startup but clearing up after it's been running is a valve issue, maybe a combination of worn guides and worn valve stem seals.
@nobodyimportant6141
@nobodyimportant6141 10 ай бұрын
I have a Westinghouse 14000W dual fuel that stops after 1/2 hour on propane. Did it 3 times. Never had any gasoline in it. Shutting down it sounds like it's overloaded. I turned off the main breaker, it still quits. Do I look at the powerhead, or the propane regulator, or is ir something else?
@Bassguitarist1985
@Bassguitarist1985 10 ай бұрын
How big is your propane tank? What are you running when it stops? What you mean it sounds overloaded?
@nobodyimportant6141
@nobodyimportant6141 10 ай бұрын
30 lb tank. Slosh test feels more than half full. Gen sounds like an overload where pitch changes. Slightly increases volume while the engine slows and eventually stalls. This happens in a period of 5-10 seconds. Can't be a real output overload with the gen breaker off the last time. Thanks for the reply.
@Bassguitarist1985
@Bassguitarist1985 10 ай бұрын
@@nobodyimportant6141 if you don't see smoke from the powerhead and none of the circuit breakers have tripped I doubt that it's an overload then. Sounds like a fuel delivery problem. I assume that it has a primary regulator at the tank connector and then the demand regulator is on the machine itself. Does it do the same thing on gasoline?
@nobodyimportant6141
@nobodyimportant6141 10 ай бұрын
@@Bassguitarist1985 Running normal house load. Guessing no more than 7kw. No range, dryer, and hot water heater breaker off. I have run this setup at least four times prior with no problem during 3-5 hours running. we have used 1200W microwave without issue.
@Bassguitarist1985
@Bassguitarist1985 10 ай бұрын
@@nobodyimportant6141 is this on gasoline or propane?
@robertsimpson7113
@robertsimpson7113 3 ай бұрын
Is THD called by another moniker? such as TRMS???
@GTOUTUBE
@GTOUTUBE 10 ай бұрын
Hello guys, is it possible to hook up a 12 volt outlet on my generator if it didn't come from the factory with one?
@jcondon1
@jcondon1 10 ай бұрын
Most generators that have a 12 volt outlet are using an auxiliary stator winding meant for that purpose. The easiest way to get 13 volts out of you generator would be a transformer plugged into the 120v AC
@pederb82
@pederb82 2 ай бұрын
As an electronics engineer I’d like to add a little on THD. If it is high the main issue is that you generate heat in the power supply of the device you are using. Especially engines. Your non Ali express phone charger has capacitors that make it handle it just fine tho the rectifier will run a little hotter. On the compressor of your fridge it will run a little harder as It’s not as smooth and also a bit hotter, but it will work and probably won’t cause harm, but it depends on how high the THD is. When it comes to electronics it basically depends on the quality of the device and how much you want to risk shorten the life of the devices you use. That said, the utility power is rarely clean. In the US the limit is 3% but I have rarely seen it less than 5%. An good inverter generator can produce 0,5% THD.
Small Engine LIVE stream for 12/28/2024
2:39:48
Ken’s Small Engine Repair - Mr. Mow It All
Рет қаралды 470
Powermate Generator Down on Power
1:08:38
James Condon
Рет қаралды 79 М.
黑天使被操控了#short #angel #clown
00:40
Super Beauty team
Рет қаралды 61 МЛН
My scorpion was taken away from me 😢
00:55
TyphoonFast 5
Рет қаралды 2,7 МЛН
人是不能做到吗?#火影忍者 #家人  #佐助
00:20
火影忍者一家
Рет қаралды 20 МЛН
Mil-Spec, the best you can do?
17:56
DavidPoz
Рет қаралды 418 М.
KSE hosts Generator Q and A with Mr. Generator James Condon LIVE
2:00:25
Ken’s Small Engine Repair - Mr. Mow It All
Рет қаралды 7 М.
Generator and Small Engine Q and A with James Condon and Gary Bernacki LIVE!
1:42:36
Ken’s Small Engine Repair - Mr. Mow It All
Рет қаралды 2,4 М.
Generac XG8000e Not Running Well - Likely Never Ran Well
1:28:13
James Condon
Рет қаралды 153 М.
Generator Not Generating - Will it Make Power Again?
54:19
James Condon
Рет қаралды 118 М.
I Bought a Military Surplus Diesel Generator to Power my House
35:24
Waldo's World
Рет қаралды 6 МЛН
Small Engine Repair Chickanic answering ALL of your questions!
12:21
Hollow  Ground Screwdriver Tips for Jet Removal
4:14
Ken’s Small Engine Repair - Mr. Mow It All
Рет қаралды 286
Chicago Electric Generator (Part 1) - No Power
53:35
James Condon
Рет қаралды 100 М.
黑天使被操控了#short #angel #clown
00:40
Super Beauty team
Рет қаралды 61 МЛН