2kW Grid Tie inverter connect to US 240V. Theoretical. Part 2 / 3. Sun-2000G2 grid tie with limiter.

  Рет қаралды 17,116

SolarEngineering

SolarEngineering

4 жыл бұрын

Part 1: • 2kW Grid Tie inverter ...
Part 3: • 2kW Grid Tie inverter ...
Connecting 2 inverters together: • Connecting 2 2kW grid ...
Inverter Amazon link: amzn.to/351gWOb
Inverter Ebay link: rover.ebay.com/rover/1/711-53...
As an Amazon Associate I earn from qualifying purchases.
As an Aliexpress Associate I earn from qualifying purchases.

Пікірлер: 91
@benkanobe7500
@benkanobe7500 2 жыл бұрын
I have watched all your KZbin regarding this set up and your final set up before moving up to Solark. I completely understand your excellent demonstrations. It is the next one where I get confused. Here is why:
@peterlindstrom8865
@peterlindstrom8865 2 жыл бұрын
Well explained from someone who is born in a 3 phase 240V country 😉
@motoprophet3981
@motoprophet3981 2 жыл бұрын
Great series on this limiter! I appreciate you taking time do do it. Thank you very much!
@JesudomEnergyGroup
@JesudomEnergyGroup Жыл бұрын
Thanks ,it’s very helpful for one of customers in USA.
@beyondfossil
@beyondfossil 3 жыл бұрын
I was thinking that limiter/throttle feature could
@NewsBroadcasting
@NewsBroadcasting
cool video, we have same unit it stopped working after 2 years , we check the DC fuses they are ok,. anyway to fix it? do we have to desolder all teh MOSFETs to check them ?
@jimthvac100
@jimthvac100
I also considered this same problem and came up with the solution of using two 100a/25ma CT's in series then would not need to worry about a resistor.
@jodymorgan9869
@jodymorgan9869 Жыл бұрын
I think the hall effect sensor only reads the voltage and axes and islanding device I don't believe it controls the wattage coming back into the system, I believe that is controlled by a internal pressure device compensating. I like your resistor idea, I would try a smoothing capacitor or it's called a surge capacitor with a diode to keep from back feeding
@RJ-cc1fz
@RJ-cc1fz 4 жыл бұрын
Very good explanation. Correction though.. the resistor is only used to make the inverters supply slightly more of the power the loads use. It will work fine without the resistor but the grid will feed roughly 100w more than it would with a resistor used.. but when using multiple inverters (in my situation) the resistor needed to be removed from the wiring to prevent backfeeding.
@thedavesofourlives1
@thedavesofourlives1
With split phase and 1 CT sensor, put both through the 1 sensor, but one (red or black) longer and run through sensor in reverse direction.
@earthenergyhex
@earthenergyhex Жыл бұрын
Thanks!
@dwey2557
@dwey2557 3 жыл бұрын
Okay because I plan to get one of the same 2KW you have but I'm going to have to connect to sensor in series like you
@rockstomper8390
@rockstomper8390 3 жыл бұрын
Hello thank you for the videos. Good stuff! OK... So lets say you have the two CTs connected to the panel feeders and your pulling 5 amps (120vx600w) on L1 and zero amps on L2. I'm thinking you will still be backfeeding the grid with 300 watts on L2 cause your output will still be a balanced output of 2.5amps L1 and 2.5 amps on L2?? Again thanks for the awesome vids. I will hit the like button right now.
@thedabbler2753
@thedabbler2753 3 жыл бұрын
I do not have a spare dryer plug. What are your thoughts on either running the AC cable directly into the breaker box, or splicing it in a junction box with some 10/2 Romex wire? When it gets to the breaker, should the ground wire from the AC cable go to the ground bar in the panel? I did not get the Marsrock branded one as you have, but the Eco-worthy and they said attach it to N. I am unsure if that is correct. Also, the AC cable they provided is only 18AWG and might get hot. Would replacing it with 16AWG be acceptable (10-13A) or did you use something else e.g. 12AWG AC cable? Thanks again for all your videos so far. They are excellent.
@popeyeswetcactus
@popeyeswetcactus
In the us, there is a ground wire. Where does this go. I dont see this on the 2000G2
@infernoal2994
@infernoal2994 4 жыл бұрын
So I have a question, with 2 ct clamps in series how does the inverter know to send for example 3 amps to L1 and 5 amps to L2?
@peterk.4266
@peterk.4266 Жыл бұрын
Hello there, how are your inverters holding up? I just bought a 2000k version, do they last?
@redstorm6767
@redstorm6767 3 жыл бұрын
Let's say I already have a grid tie solar system and the electric company has decided to shift time of use rates so that they charge more for electricity in the late afternoon. I want to use this type of setup to offset my consumption from the grid during that time, and then charge my battery bank back up during the night when rates are cheaper. My current solaredge system completely shuts down when the grid goes down. Do you know if this inverter will trick the solar inverter to stay up during an outage?
@ischramm
@ischramm
hello everything is fine? What happens if one of the phases goes off (L2 for example)?
@dwey2557
@dwey2557 3 жыл бұрын
Hello is the 2KW grid tie inverter still working for you?
2kW Grid Tie inverter with limiter. Review. Part 1 of 3. SunG Grid.
3:21
Alex hid in the closet #shorts
00:14
Mihdens
Рет қаралды 18 МЛН
Inside Out Babies (Inside Out Animation)
00:21
FASH
Рет қаралды 23 МЛН
Playing hide and seek with my dog 🐶
00:25
Zach King
Рет қаралды 37 МЛН
Sun 2000 GTIL2 Inverter full test. How it works, what it does.
34:30
Off-Grid Garage
Рет қаралды 76 М.
SunG Grid tie inverter. Menu detailed review/explanation.
8:16
SolarEngineering
Рет қаралды 19 М.
SUN-1000G2-M Изучение, подключение
21:04
Вадим Перелыгин
Рет қаралды 1,9 М.
SHTF - Cheap Emergency Solar Power! Use Any SINGLE Solar Panel! 1/2
21:13
Nate's DIY Solar
Рет қаралды 254 М.
Alex hid in the closet #shorts
00:14
Mihdens
Рет қаралды 18 МЛН