Great video, thanks for sharing! In a scenario where the inverter is located 140 meters from the main house and meter, are there alternative communication methods besides running a physical CT cable? Also, if a backup generator is part of the system, does the inverter necessarily need to be near the main meter for proper operation? How does the system ensure export shut down during a power outage to comply with safety regulations?
@solis7119Ай бұрын
Can consider to use smart meter for measurement and extend the meter communication cable instead of extending the CT cable. Backup generator can be connected on grid side with ATS or directly on gen port of the inverter. Not necessarily must be close to the main meter. Export limiation is achieved by the smart CT/Meter measurement on the grid conncection point, inverter will automatically adjust the PV generation and battery charge/discharge power to ensure system export limit is followed.
@thomasdsouza2244 ай бұрын
Informative to help us installers. Look forward to your paralleling video - it is becomming all too common in our installs, allows to increase the number of MPPTs in a system. What is the model of the Easton that you showed?
@nicolasnunezgarces805423 күн бұрын
how to set up the inverter in injection 0 ???? Thanks for the video !
@ewolfe99911 ай бұрын
Will the 4MPPT three phase version be coming to Australia? If so, do you know when it will be available?
@solis7119Ай бұрын
You can try this S6-EH1P8K-L-PLUS-AU, which has 4MPPT.
@GameVerseX50083 ай бұрын
Solis S6 Pro 6KW Hybrid inverter works without batteries?
@Sawa_i3 ай бұрын
Workable...
@solis7119Ай бұрын
Even without batteries, it can be connected to the grid normally
@ronaldopinili22466 ай бұрын
What could be the reason why after logging the data logger, then going onto the router connection, my home wifi doesn't appear in the selection list though is a 2.4 ghz not 5G... please guide... Thanks!
@PowerXCells4 ай бұрын
I am an installer/technician (whichever applies to you) and would like to set up an account to monitor multiple solar systems for my clients. Could you please provide me with the following information: 1. Steps involved in creating a SolisCloud organization account. 2. Any specific requirements for installers/technicians registering for an organization account. 3. Resources or guides available to help with the setup process.
@lomadr13615 ай бұрын
The pair of dc input, what is the max voltage in each input?
@muhammadibrar62757 ай бұрын
I am facing an issue with the SBU The inverter prioritizes battery use (SBU mode) and switches to battery when the grid goes down. This behavior is normal except in a specific situation: When the battery voltage reaches 44.5V and the grid is still available, the inverter switches to grid power while also charging the battery. If the grid then goes down while the battery voltage is between 44.5V and 50V (e.g., at 50V), the inverter doesn't automatically switch back to battery, resulting in a blackout.
@solis71196 ай бұрын
Please check what values you set on the overdischarge voltage/focecharge voltage. When voltage is lower than overdischarge voltage setting, hybrid inverter will stop using battery power. When voltage is lower than forceharge voltage, it will trigger the forcecharge logic and may take power from grid. And please contact our local service team who will help you troubleshoot in details
@muhammadibrar62756 ай бұрын
@solis7119 please creat android app for Google TV too.
@kamrankhan-cq8zi2 ай бұрын
HI Have issue in morning inverter charge the battery from pv but did not shift pv energy to backup . When we disconnect or shift inverter to off grid then pv through energy to backup. Any solution that can work automated
@solis7119Ай бұрын
Please contact Solis local service team☀
@mohammadmougharbel3015Ай бұрын
Hi dear can i connect solis 8kw hybrid inverter to 2 FLA felicity solar batteries. how can i know ?
@solis7119Ай бұрын
After connecting two Felicity batteries in parallel, connect them to an 8kw hybrid.☀
@jmadawg Жыл бұрын
Ports seem very similar to Deye/Sunsynk - no bad thing!
@melalbano63513 ай бұрын
What if Solis would have LCD accessories monitoring.
@erwingeorge61878 ай бұрын
Please confirm the start up voltage for this inverter. Hopefully it's not 300 to 400 volts. That would not be fine.
@solis71196 ай бұрын
90Vdc
@TeodardoJrRubin11 ай бұрын
Please make a video about pure off-grid setup.
@splldaspllda81299 ай бұрын
Can grid and generator both can supply electricity simultaneously
@solis71196 ай бұрын
Yes
@VincedTubb-ow6fgАй бұрын
Can i know what is the grid code settings for philippines?
@solis7119Ай бұрын
Just need to select 'Philippines' option in grid code selection.
@hasithmanjitha545 Жыл бұрын
I can't log in to solis app It's showing bad gateway error always
@solis71196 ай бұрын
Please contact our local service team who will help you troubleshoot in details
@tusharsuvro8317Ай бұрын
7:59 Can you please share with me the link to the parallel inverter installation video the one you are talking about? I have two S6-EH1P8K-L-PRO inverters for commissioning. @Solis7119
@solis7119Ай бұрын
kzbin.info/www/bejne/mGjdmaJug56lhKM Hope it helps.
@vincentnicholas64 Жыл бұрын
How do I set this type of inverter not to export surplus to the grid?
@solis71196 ай бұрын
Use the "Feed in power limit" function on the APP
@usergameshow9 ай бұрын
Is this work without battery
@rehanaaziz75827 ай бұрын
yes
@solis71196 ай бұрын
Yes, you can set "no battery" mode in battery model selection, and use it as a normal PV grid tied inverter
@nurudeenlawalsaid7264 Жыл бұрын
Pls how do I reset/recover the installer password as my installer is no more in my town and can't get access. Also the inverter is showing faultshutdown. Fault is.. no. Grid detected. However grid power is connected but no CT as it is lost in transit.
@herbertpalines46956 ай бұрын
The same concern here, need to reset the installer account.
@solis71196 ай бұрын
Long press the power icon on the LED ribbon for 5s, then you can reset the bluetooth password.
@muhammadusmanbabar86605 ай бұрын
How to reset owner password as i forget that/ not able to login
@energyshiftsolarservices Жыл бұрын
Could you let us know what we can use the generator port as the second output load port?
@haqiqiazaditv19 ай бұрын
Never
@solis71196 ай бұрын
You can use it as a second critical load backup port, for example, when in off grid condition, both GEN and backup port can be supplied, when battery SOC reached a lower level that you set, it can cut off GEN port automically and focusing on supplying power to the backup port load. In this way ,you can prioritize you loads.
@TheMegatot6 ай бұрын
how to update firmwire online?
@solis71196 ай бұрын
You can contact our local service team for helping you update your inverters remotely. You just need to make sure the inverter is online on Soliscloud.
@khalilkhokhar34557 ай бұрын
Please Guide installer account reset sittings
@herbertpalines46956 ай бұрын
Hello! I have the same concern here. Thanks in advance for your response.
@solis71196 ай бұрын
Long press the power icon on the LED ribbon for 5s, then you can reset the bluetooth password.
@herbertpalines46956 ай бұрын
@@solis7119 thank you!
@kinka97 Жыл бұрын
Hey this guy is nice, but what's up with his hair?
@naylinhan57956 ай бұрын
How to select 220AC output ...now pre selected 230VAC which is not suitable for some appliance in my place.? Please explane thanks.
@solis71196 ай бұрын
Just need to select a 220V grid code. When with grid connected, voltage is depending on utility, inverter can adapt to a wide range of voltage without problem. Only in off grid operation, the voltage output on the backup port is determined by the inverter, the backup voltage is settable in the Solis APP.