Sorting out a complete mess of a fuse board - Electrician Life

  Рет қаралды 31,153

Artisan Electrics

Artisan Electrics

Күн бұрын

Sorting out a complete mess of a fuse board - Electrician Life.
Join Cory and Me as we continue the job where I install the AFDD Consumer Unit. Cory is doing abroad change and it's a bit of a nightmare!
Watch the other part of this day of work with me fitting a new AFDD consumer unit and conduit here: • Installing an AFDD Con...
🔔 Join This Channel To Get Access To Perks 👇
➤ / @artisanelectrics
🧰🛠️ Tool Of The Day 👇
Wiha Electricians Hammer: amzn.to/2PONSWq
R2 Wander Lead: amzn.to/31XATEw
✅ Check Out All Our Favourite Tools Here 👇
➤ www.amazon.co....
-----Electricians Business Course-----
📩 Sign Up To My Electricians Business Course Here And Get The First 4 Lessons Free 👇
➤ course.electri...
🔔 Subscribe to TOOLS4SPARKS KZbin Channel 👇
I Also Have A Dedicated KZbin Channel About Tools:
➤ / tools4sparks
-----TESLA REFERRAL CODE-----
🚀 You Can Use My Referral Link To Get 1,000 Free Supercharger Miles On A New Tesla 👇
➤ ts.la/andrew24855
-----MY ENERGY PROVIDER-----
🐙 Get £50 credit when you switch to Octopus Energy 👇
➤ share.octopus....
🏷️ DISCOUNT BUSINESS SUPPLIES 👇
➤ www.amazon.co....
-----TRADES INSURANCE DISCOUNT-----
If you need to renew your public liability insurance or need tools in van insurance, I recommend Rhino Trade Insurance, i've just renewed my insurance with them.
🏷️ Use My Discount Code “ART5” and you get a 5% Extra Discount On Their Already Excellent Prices.
➤ www.rhinotradei...
📞 or call 01162437904.
📱 Don't Forget to Follow Social Media, FOLLOW US on Your Favourite Social Networks 📱
📸 Artisan Electrics Instagram Account 👇
➤ / artisanelectrics
🐦 Artisan Electrics Twitter Account 👇
➤ / artelectrics
📓 Artisan Electrics Facebook Account 👇
➤ / artisanelectrics
ADVERTS THAT SUPPORT THE CHANNEL:
Thanks for your support!
This video is for entertainment purposes only please do not attempt to copy or recreate. Do so at your own risk.
#sparkylife #electricianlife #artisanelectrics

Пікірлер: 144
@artisanelectrics
@artisanelectrics 3 жыл бұрын
Join this channel to get access to perks: kzbin.info/door/UYJhbsrC1bvVWzgUq83K4Ajoin Tools of the day: Wiha Electricians Hammer: amzn.to/2PONSWq R2 Wander Lead: amzn.to/31XATEw
@mikeselectricstuff
@mikeselectricstuff 3 жыл бұрын
Magnetic field effect on a lighting circuit would be way too small to be an issue. My steel CU has tails coming into two seperate holes - I checked with a thermal camera with about 35A load and saw no measurable temp rise. It might be an issue on heavy duty industrial setups but insignificant in a domestic situation.
@callumBee
@callumBee 3 жыл бұрын
JW did a video on this with 100s of amps and there was no real considerable temperature rise.
@ColinRichardson
@ColinRichardson 3 жыл бұрын
@@callumBee good olde JW
@MrKarlPrince
@MrKarlPrince 3 жыл бұрын
A rise in temperature is more likely to come from the resistance of a cable than induced eddy current in consumer installations
@Chris-hy6jy
@Chris-hy6jy 3 жыл бұрын
The whole "tales through separate holes" thing is a complete non-issue. It's just yet another stupid unnecessary regulation. Got to keep the regs people in a job I guess! 🤦‍♂️
@acelectricalsecurity
@acelectricalsecurity 3 жыл бұрын
After seeing jw's video on single cables entering metal enclosures, you definitely wouldn't have to worry about that in a domestic installation
@adrianstavrakis9126
@adrianstavrakis9126 3 жыл бұрын
Ι really think it's much easier to use a tone generator to find wires and just go around with the beeper/tracer at hand...
@waynenrich
@waynenrich 3 жыл бұрын
Oh the ramblings of Corey 🤣
@AndyK.1
@AndyK.1 3 жыл бұрын
Sounds like he needs a therapist 😂
@waynenrich
@waynenrich 3 жыл бұрын
@@AndyK.1 🤣maybe 🤫🤔
@zu1875lu
@zu1875lu 3 жыл бұрын
He is a bit of a naus 😐
@robertburrows6612
@robertburrows6612 3 жыл бұрын
When you want to find were those odd cables go , use a cable tracker , it saves walking around with wander lead , just need to connect the transmitter to the end of a cable and the you walk around touching the accessories with the receiver
@UberAlphaSirus
@UberAlphaSirus 3 жыл бұрын
yup. And if your gonna use the wander lead, use a multimeter on continuity reather than waiting around with the tester.
@ForTheBirbs
@ForTheBirbs 3 жыл бұрын
Cable tracer is the way to go. Can save a lot of time.
@BarneySaysHi
@BarneySaysHi Жыл бұрын
The cable tracker did wonders when I was working in a datacentre.
@garethg2501
@garethg2501 3 жыл бұрын
Could always gland the SWA into a PVC enclosure, which is then bushed to the underside of the top trunking. Keeping the inner insulation and bedding run all the way into the consumer unit.
@adrianupnorth
@adrianupnorth 3 жыл бұрын
Nice to see a genuine day. We all been there with a small easy job. You really do learn something every day!!
@damienhanson4929
@damienhanson4929 3 жыл бұрын
Singles is another good way to keep amount of cables at light fittings down. Neutral in neutral out and one switch wire. Permanent singles feed to switches only and switch wire up to light.
@colingreenwood987
@colingreenwood987 3 жыл бұрын
Here in Aus, SDI cable is dearer than twin actives. We always run the 2 core. At worst case there is a spare for any future upgrades or faults.
@acelectricalsecurity
@acelectricalsecurity 3 жыл бұрын
It's always done that way in conduit, not that common outside of a conduit system, would probably be more expensive these days as well.
@Bin216
@Bin216 3 жыл бұрын
The armoured cable: gland the armoured cable into a non-conductive box/conduit, and label as “Caution: Independently earthed at remote end. Do not to connect to local earth.”. That way you have shown that you could have connected the earth, but not doing so an obviously explicit choice rather than a potential cowboy installation.
@9plusinstalaciones
@9plusinstalaciones 3 жыл бұрын
Eddy currents on a single cable going through a metal hole really wouldn't be an issue.
@tobysherring1369
@tobysherring1369 3 жыл бұрын
John Ward tested the effect when tails are put through separate holes in metal. There was virtually no effect at the sorts of currents carried by tails, so you don't need to worry about a lighting circuit. It's certainly not "against every reg."!
@jongurney
@jongurney 3 жыл бұрын
When he first mentioned it I thought he was on how the singles were gonna create a giant induction loop :D
@9plusinstalaciones
@9plusinstalaciones 3 жыл бұрын
@@tobysherring1369 virtually no effect with hundreds of amps flowing. It's not an issue.
@chrisrogers2848
@chrisrogers2848 3 жыл бұрын
Might not be an issue in practice, but it is in the regs
@sfsldk6890
@sfsldk6890 3 жыл бұрын
@@chrisrogers2848 Regs are non statutory remember. Common sense needs to be used
@tommymack3210
@tommymack3210 3 жыл бұрын
This channel is my favorite of all the UK Electricians Channels, second must be Tools For Sparks channel ;)
@aroncells3120
@aroncells3120 3 жыл бұрын
Very nice and relaxed way of explaining things , thanks for the upload 👌
@davidfaraday3085
@davidfaraday3085 3 жыл бұрын
The extension on my house uses single & cpc cable for the lighting wiring. Makes a change from the VIR single (no cpc) used for lighting in the original part of the house. Edit: I wouldn't worry too much about the magnetic field associated with single cables. John Ward did a video on the subject and showed that unless you are passing ridiculous amounts of current through the wires it really is a non-issue.
@AndyK.1
@AndyK.1 3 жыл бұрын
They did do pvc with no cpc. Double insulated. In the 60s
@jensschroder8214
@jensschroder8214 3 жыл бұрын
I made a change a few years ago. It was on a staircase. First the cable came from the fuse and went through the on-off switch and from there three-pole cable (hot switched, neutral, earth) to the lamp. It was all already built. Then it should become two switches. The switch was exchanged for a pushbutton. I had to get hot again via a separate cable. Neutral and earth from the old cable. Everything in one big box neat the lamp, the old cable from the first push button with neutral and earth, the cable with the new hot, the cable to the second push button (hot and switched), the cable to the lamp and an impulse switch. It was easier to change the cable closer to the lamp and from there to connect the second pushbutton and impulse switch closer to the lamp. But I needed the hot without a switch via an extra cable.
@projectartichoke
@projectartichoke 3 жыл бұрын
I had knob and tube wiring like that for old three way switches in my house. Of course everything was single conductors, but usually two were run near each other.
@Satters
@Satters 2 жыл бұрын
6241Y is used in 2plate wiring Neutral looped around the ceiling roses, Line looped around the switches, exactly as it would be in conduit but in sheathed wiring, instead of 3plate loop in wiring using 6242Y where line is also looped at the ceiling roses the more common method of sheathed wiring
@kevy427
@kevy427 3 жыл бұрын
An enjoyable video of what it’s really like at the coalface, and I can only hope the collapsing shelf was caught on film?! Jordan, please invest in fibreglass steps
@NathanOlooney
@NathanOlooney 3 жыл бұрын
Sadly I cut the camera just before it happened! Typical!
@RichardArblaster
@RichardArblaster 3 жыл бұрын
20:16 "Ring of Armus" a new superhero weapon 😆😆😆
@Marcel_Germann
@Marcel_Germann 3 жыл бұрын
That's all around the world with building in a neat new board, but you still have a mess of old crap work around it. And here in Germany that's also a thing, especially due to that it was permitted until 1973 (in East-Germany until 1990) to have TN-C in final circuits, so no separate CPC, instead you got a PEN there. You can't install modern RCD protection in such old circuits, all RCDs and RCBOs we use here not only switch off the line, they also switch off the neutral. And it's not permitted to switch a CPC or a PEN. And as long as the installation is still intact and meets the requirements from back then, you can't force the owner to replace it. You can only recommend a modernisation. The only thing you can do is implement MCBs only in a new board, and on extensions be creative and implement something like an outlet with integrated 30mA type A RCD, which is btw. far more expensive than a rail mounted RCD (material cost is round about 130 Euros for them), and split the PEN from there into a separate neutral and CPC and then at least the extension is meeting modern standards.
@Ragnar8504
@Ragnar8504 3 жыл бұрын
Yeah and in the part of Germany that used to be behind the Iron Curtain, TN-C with 2.5 mm Al wire was permitted until 1990. Plenty of that still around! Only kitchens and bathrooms required RCD protection from 1984 onwards and were therefore wired in three core instead of two core (black and yellow/green).
@SuperUltimateLP
@SuperUltimateLP 3 жыл бұрын
A way bigger epidemic is the Fakt that there are still so many houses in Germany that still have the type "H" resettable fuse. (A relic from the 60-70s they stopped selling them in 1977) So many houses could be saved from burning down if there owners knew what the heck is in there fuse board.
@Ragnar8504
@Ragnar8504 3 жыл бұрын
@@SuperUltimateLP H-curve MCBs have rather poor overload protection (thermal trip) but that's something they share with their successor, type L. Combined with the German obsession with putting 1.5 mm on 16 amp MCBs that can cause overheating. The same is true of Diazed/Neozed gG/gL fuses BTW! The main purpose of H curve MCBs was offering fault protection in TN-C(-S) systems with high Zs, the magnetic trip is very fast at 2-3 times rated current. Of course that's quite annoying if you're using anything that has a high (-ish) inrush current, especially motors. The Austrian regs recognised the overload issue fairly early on and reduced the maximum overcurrent protection size of 1.5 mm to 12 amps under most circumstances, along with the introduction of L12 A MCBs in 1980. This historic relic is the main reason why B13 is still the most common household MCB size in Austria, even though the regs now allow B16 for 1.5 mm unless the cable is embedded in insulation.
@SuperUltimateLP
@SuperUltimateLP 3 жыл бұрын
@@Ragnar8504 i wouldn't call it a obsession ;) I my self only use neozed fuses as a prefuse not as a primary. People tend to screw in what ever fits even if I install a ring (don't know how to say it in english) to prevent the wong fuse from being inserted, idiots pull them out and screw in a 63A because "the previous one was obviously to small". 1,5 is to my knowledge only allowed for lighting and low usage circuits. Everything thata has high power draw needs to be 2.5 for example washing machines/dryers.
@Ragnar8504
@Ragnar8504 3 жыл бұрын
@@SuperUltimateLP With some electricians I do feel it's a bit of an obsession :-) The VDE regs let you have 1.5 mm on a B16/C16 in some circumstances - installation methods Bx (singles or cable in conduit) or C (cable on or in wall), two current-carrying conductors, no derating for bundling or higher ambient temperature. Despite the fact that most new construction is all method Ax (singles or cables in conduit in insulation, cables directly in insulation), 1.5 mm and B16 are still the most common choice in German domestic electrics. Apparently at the onset of WWII the current-carrying capacity of 1.5 mm Cu/2.5 Al was increased to 16 amps in order to deal with wartime shortages and that change was never repealed. Eventually, manufacturers pushed 16 amp MCBs in such quantities that they were discounted heavily, eventually giving us the "€ 1.99 B16 single-pole", which in turn caused electricians to use only B16s because everything else was at least twice as expensive. Conscientious electricians will use 2.5 mm for high-power loads but 1.5 mm can still be acceptable. Besides, most modern washing machines and dryers don't exceed 10 amps, even some ovens don't. I recently looked at a used IKEA oven from the late 2000s and it was less than 2 kW if I remember correctly!
@andrewyeo2353
@andrewyeo2353 3 жыл бұрын
From the thumbnail I thought piers morgan was going to do a board change gosh can you imagine the critical remarks he might just walk off site 😁
@waynenrich
@waynenrich 3 жыл бұрын
U mean morbidly obese Morgan do manual labour now that would be fun 🤩
@samuelgilbert9734
@samuelgilbert9734 Жыл бұрын
I live in Canada and I'm kind of surprised since every single cable entering a loadcenter (what you call the consumer unit) has to have a cable clamp when entering the enclosure.
@linksone6287
@linksone6287 3 жыл бұрын
Intriguing stuff mate. Well done once again for another well displayed content. 👍🏾
@artisanelectrics
@artisanelectrics 3 жыл бұрын
Glad you enjoyed it
@UserName-yk7om
@UserName-yk7om 3 жыл бұрын
I think at 3:25 Cory is right. In the UK the left-hand-rule should apply, while many other countries use the right-hand-rule, so either rule is in sync with the traffic on the streets. Otherwise the magnetic fields would't cancel out with the cars, driving on the other side. Trust me, I'm an engineer 😏
@johnbrown-so3vz
@johnbrown-so3vz 3 жыл бұрын
Magnetic coupling is an issue when using metal containment. It may not cause a noticeable voltage but 2 things come to mind. Inductive impedance and corrosion.
@Cleofizoid
@Cleofizoid 3 жыл бұрын
That retractable Wander Lead is awesome. Wish I could find one in the US.
@artisanelectrics
@artisanelectrics 3 жыл бұрын
Watch part 1 here with me fitting the AFDD consumer unit and conduit: kzbin.info/www/bejne/gXvJk5ukirB-i6c
@seanward8139
@seanward8139 3 жыл бұрын
I work on site/commercial and use single core and earth quite often for emergency lighting. Just to carry a permanent feed from the key switch to each emergency light on the circuit. However I have worked on some domestic/house bashing projects and not come across it on any of them so quite strange when you put it across as a house bashing thing 😂
@stevespoor6567
@stevespoor6567 3 жыл бұрын
Where does the neutral come from?
@uplightuk8924
@uplightuk8924 3 жыл бұрын
@@stevespoor6567 I think he’s trying to say that when there are lights that have been wired in just T&E and don’t have a permanent at the light. EM lights need a permanent do they bring in the 1 core cable alongside the existing T&E just to bring a permanent to the lights? That’s the only way I can think of doing it
@seanward8139
@seanward8139 3 жыл бұрын
@@stevespoor6567 wired in t and e as normal then each fitting that has a battery pack for an em has a single core and earth running to it as a perm live
@tww5719
@tww5719 3 жыл бұрын
Never seen a double sheath singles with a ccp,yes your right mainly used for strappers,not sure why it's going to the mains though 👍
@cocoino2307
@cocoino2307 3 жыл бұрын
they may have a borrowed neutral
@tww5719
@tww5719 3 жыл бұрын
@@cocoino2307 yeah strange one,but surely they would of taken a t@e to the first light ,will have to see in the next vid 👍
@AndyK.1
@AndyK.1 3 жыл бұрын
Neutral direct to the light and line via the 2 way switches to the light. Means you didn’t have to use 3c+e which was rare
@tww5719
@tww5719 3 жыл бұрын
@@AndyK.1 yes your right,t@e came on the market in the 70s and triple did not exist for a at least a few years later,hence the singles,I didn't see a separate neutral at the board,which would sought of explained 👍
@AndyK.1
@AndyK.1 3 жыл бұрын
@@tww5719 Singles (double insulated) existed in 1966.
@cumberland1234
@cumberland1234 3 жыл бұрын
I’m under the impression that SWA cable ought to be earthed at it’s supply end, I think it’s in one of the annexes of the British Standard for the cable type. As long as the armour is earthed though I don’t see it as a massive issue.
@JohnCanty93
@JohnCanty93 3 жыл бұрын
Corey’s been on the red bull 🤣
@artisanelectrics
@artisanelectrics 3 жыл бұрын
🤣
@scottsparky1
@scottsparky1 3 жыл бұрын
Easyer way to trace a cable is use a data tone tester the you can just wave it next to the cable without having to remove face plates. And the ones you find it use your tester to confirm
@colingreenwood987
@colingreenwood987 3 жыл бұрын
In Australia we can't use Al ladders for any elec work. Surprisingly you haven't got fibreglass step ladders for the boys Jordan. If Corey supplies his own, you should put should just ban it. They are not worth the risk. Love the channel
@eamonnohalloran2254
@eamonnohalloran2254 3 жыл бұрын
Why are you working off an aluminium ladder Cory? Big NO NO.
@oyleyhands1332
@oyleyhands1332 3 жыл бұрын
Don't you guys use tone testers for tracing dead cables ? that dragging a long lead around is sooo primitive 😉
@johnfenlon458
@johnfenlon458 3 жыл бұрын
Great Job! I noticed the black meter on the left side corner Cory removed it. Can you send me? heh.. Thumb up Cheer!!!!
@mikeenglish1492
@mikeenglish1492 3 жыл бұрын
Another quality install 👍
@Chris_In_Texas
@Chris_In_Texas 3 жыл бұрын
I am disappointed, that I didn't get a hello in American! 😎🤷‍♂️ Cory did every other language!
@stevengrace6712
@stevengrace6712 3 жыл бұрын
Corey have an energy drink this morning? Great video as always!
@GreenHawkConstructionltd
@GreenHawkConstructionltd 3 жыл бұрын
Loads of houses round my way have single and earth it’s great especially when it’s been messed about by the homeowners 🥴🥴🥴
@goaway9487
@goaway9487 3 жыл бұрын
Someone I worked with decided to do chin ups on a loft beam Just as the customer walked in... Didn't hear the end of it from the customer.
@lin-fel
@lin-fel 3 жыл бұрын
A lot of new houses lighting circut were wired in single and earth in my time as a electrician on large building sites .
@havoctrousers
@havoctrousers 3 жыл бұрын
I did a 1970s house the other day where they'd used sheathed singles for the lighting. CPCs were their own singles to the luminaires, but no CPCs had been run to the switches. Switch returns went straight to the fittings in a sheathed single and there was only one "junction box of doom" per floor to connect all the CPCs, neutrals for the fittings and the perm lives down to the switches. Quite an efficient use of cable and JBs, but a bit of a nightmare of ripping up floors if you don't know where that junction is.
@AndyK.1
@AndyK.1 3 жыл бұрын
Common in the 60s for 2 way switching.
@lin-fel
@lin-fel 3 жыл бұрын
@@AndyK.1 There was a lot of new houses in the 70s lighting circuts complete wired in singles and earth .
@Stuart_Johnson_Solutions
@Stuart_Johnson_Solutions 3 жыл бұрын
Personally I wouldn't have wanted the extra junction on the feed, I'd have located the meter at the natural end of the cable when routed cleanly, and run the tails to match.
@lewistempleman9752
@lewistempleman9752 3 жыл бұрын
Whats a good brand of wanker leads?
@ColinRichardson
@ColinRichardson 3 жыл бұрын
With this many borrowed lines, borrowed neutrals, I feel just testing CPC to see where a circuit is going may not be enough to tell the whole story
@stevecraft00
@stevecraft00 3 жыл бұрын
I work in council houses and they still spec lighting circuits in sheathed singles. We use live and earth, and separate neutrals. The lives loop around all the switches and the neutrals loop around all the lights. Obviously in council houses they don't expect people to be fitting smart switches etc so neutrals at switches isn't a consideration yet. Strappers are done in twin and earth. Out of interest you used to be able to get red sheathed red and earth. They used this as permanent lives, then normal grey sheathed red and earth for switched lives. Then you could tell at a glance what was what in your switch drops. We come across a lot like this wired in the early 90s.
@artisanelectrics
@artisanelectrics 3 жыл бұрын
Wow thats mad
@uplightuk8924
@uplightuk8924 3 жыл бұрын
My company do tons of council work (Rewires, EICR, CU changes etc. And I have never ever seen it wired like this. It’s all standard T&E just loop in/out at the lights instead of the switches. The way you explained seems like a very odd way of doing it and a longer way
@stevecraft00
@stevecraft00 3 жыл бұрын
@@uplightuk8924 it's not the way I'd choose to do it but the way we're told to do it. I did come across a private house recently that was wired in singles in 2005. Black neutrals and brown lives 😂
@lin-fel
@lin-fel 3 жыл бұрын
@@uplightuk8924 There is a lot of houses wired like this singles and earth lighting in the east midlands .
@uplightuk8924
@uplightuk8924 3 жыл бұрын
@@lin-fel Fair enough. I’m in Bedfordshire/London area I haven’t seen any houses like that at all down these sides
@blackbird700
@blackbird700 3 жыл бұрын
why didn't you put DIN rail mounted meter?
@arniewheeler4673
@arniewheeler4673 3 жыл бұрын
Cory... nice guy, but.. you crack me up mate, keep up the humour , love it.. :-)
@roberts148
@roberts148 2 жыл бұрын
May sound very passive aggressive, but shouldnt the meter be put on fire protective board, no?
@keis9396
@keis9396 3 жыл бұрын
5:09 "como esta po" jajajajajaja me mate de la risa xD saludos desde Chile
@NathanOlooney
@NathanOlooney 3 жыл бұрын
Como nativo ya 😂
@RichardArblaster
@RichardArblaster 3 жыл бұрын
Great job 😎
@dannywoods3148
@dannywoods3148 3 жыл бұрын
What veto bag is Corey using in this video ?.
@lightbreezy
@lightbreezy 2 жыл бұрын
That’s not a spider. Come to Oz and see a real spider!
@HeathenHacks
@HeathenHacks 3 жыл бұрын
24:11 Isn't that the start of the "Indiana Jones" theme music?
@tobysherring1369
@tobysherring1369 3 жыл бұрын
SWA into Wiska box where it enters the room, then t+e into trunking.
@jontownsend8090
@jontownsend8090 3 жыл бұрын
Locations can be deceptive, tiny anex, big problems. Hence you can't polish a turd.
@tobysherring1369
@tobysherring1369 3 жыл бұрын
What a waste of time and money upgrading tails from 10 to 25mm2 "proper tails". The 10mm2 is "proper" in this situation. I don't think anyone would ever get a separate 100A supply to such a small building. 10mm2 = 65A so fine for 60A supply - my whole house is on 60A.
@DrGreenGiant
@DrGreenGiant 3 жыл бұрын
Until they get electric oven and hob, electric shower and a car charger, i guess?
@tobysherring1369
@tobysherring1369 3 жыл бұрын
@@DrGreenGiant electric oven and shower already, on 60A tails. Yes, a car charger would be the time to separate the supplies and ask for 100A, and upgrade tails. But do they plan to put a charger on an annexe? Do they have planning consent to make a separate dwelling? The shed wiring video that goes with this has bizarre specs at customer's request, but the annexe wiring is apparently based on Cory's ideas rather than customer's request. It doesn't seem to add up.
@DrGreenGiant
@DrGreenGiant 3 жыл бұрын
@@tobysherring1369 Very fair point, yeah
@tobysherring1369
@tobysherring1369 3 жыл бұрын
@@DrGreenGiant people often say they'll put a 10mm2 in for a cooker in case of future upgrade. But 6mm2 rated at 57A will take even the largest double oven range at 50A. And that's suggesting it's on full all the time, ignoring diversity which is detailed in the regs.
@steveb1856
@steveb1856 3 жыл бұрын
If you see a single and CPC line on lighting then you can look forward to a borrowed neutral hiding somewhere else!
@havoctrousers
@havoctrousers 3 жыл бұрын
stick all lights in the same RCBO and take the rest of the day off :D
@steveb1856
@steveb1856 3 жыл бұрын
@@havoctrousers As a DIYer I ran new 3core and earth and fixed it properly before the spark came to do the EICR and board change 🤣
@AndyK.1
@AndyK.1 3 жыл бұрын
@@steveb1856 Best to sort it correctly before the paper monkeys turn up. 😂
@chrisdavies6633
@chrisdavies6633 3 жыл бұрын
Where’s the apprentice gone
@robertwilliamson3934
@robertwilliamson3934 3 жыл бұрын
Not sure but the issues seemed to be with the wiring in the garage to put a new board on seemed to be putting a sheen on a turd Think it would have been easier to read wire the garage which was obviously old if it in singles prob an industrial spark wired it feed at one end sw at other Would have been quicker than changing a small cu over 2 days
@SultansKitchen1
@SultansKitchen1 3 жыл бұрын
Another great video,👍🏼 Cory's rambling can entertain me for hours.😂Can you possibly demonstrate how to test the safe working load of the shelf. How would you accurately measure the tool scattered on the floor from the distance of the shelf collapse radius, could you use for example Pi (π)? 🤣
@glopena3986
@glopena3986 3 жыл бұрын
nice loadout hoddie ;-)
@henrikostrov482
@henrikostrov482 3 жыл бұрын
Where the thing was going then in the kitchen i mean the single fuse
@ADF-js9vi
@ADF-js9vi 3 жыл бұрын
Put the meter where it's easy to read.
@10p6
@10p6 6 күн бұрын
Is good Electrition practice using a metal ladder? Definitely not.
@conlon861
@conlon861 3 жыл бұрын
What's that hoodie Cory's wearing?
@Tools4Sparks
@Tools4Sparks 3 жыл бұрын
AWESOME
@ValorHeart
@ValorHeart 3 жыл бұрын
What is "anex"?
@alreadynuked
@alreadynuked 3 жыл бұрын
Artisan Shelving
@artisanelectrics
@artisanelectrics 3 жыл бұрын
🤣
@NathanOlooney
@NathanOlooney 3 жыл бұрын
T-shirt coming soon 😂
@steverobinson8170
@steverobinson8170 3 жыл бұрын
the single neutrals often used when you need to remove a borrowed neutral
@mrg4722
@mrg4722 3 жыл бұрын
Move over Jordan, there's a new presenter in town :-)
@AndyK.1
@AndyK.1 3 жыл бұрын
It’s getting worse than the bbc for repeats 😂
@danielwilliams603
@danielwilliams603 3 жыл бұрын
What kinda gcse grades do u require to do a electrician apprenticeships??
@dc-sd3gd
@dc-sd3gd 3 жыл бұрын
None. You can do them along side of your apprenticeship
@SqwarkParrotSpittingFeathers
@SqwarkParrotSpittingFeathers 3 жыл бұрын
PhD in public speaking, performance art, and, psychology.
@AndyK.1
@AndyK.1 3 жыл бұрын
I guess maths and physics help.
@sfsldk6890
@sfsldk6890 3 жыл бұрын
English maths sciences A*-C (or whatever the equivalent is now) but a lot of colleges will let you do a small course like functional skills during your college time if you don’t get those grades
@artisanelectrics
@artisanelectrics 3 жыл бұрын
🤣👍
@awhitaker2889
@awhitaker2889 3 жыл бұрын
Just another day....
@Alan.Moffat
@Alan.Moffat 3 жыл бұрын
It's OK to say you don't know....
@johnholllander
@johnholllander 3 жыл бұрын
Basically 🤪
@AndyK.1
@AndyK.1 3 жыл бұрын
They are both doing it now. 😂
@zjzozn
@zjzozn 3 жыл бұрын
Dave 🥸👍
@moodyga40
@moodyga40 3 жыл бұрын
speaking pinoy po
@LoudAsFuckk
@LoudAsFuckk 3 жыл бұрын
I would maybe have glanded it into a jb before bringing it into the trunking
Awkward Consumer Unit Change - Electrician Life
19:03
Artisan Electrics
Рет қаралды 45 М.
Fault Finding a Scary Lighting Circuit - Electrician Life
20:57
Artisan Electrics
Рет қаралды 60 М.
ЭТО НАСТОЯЩАЯ МАГИЯ😬😬😬
00:19
Chapitosiki
Рет қаралды 3,6 МЛН
Когда отец одевает ребёнка @JaySharon
00:16
История одного вокалиста
Рет қаралды 7 МЛН
Back On The Tools! Toughest Zappi Install EVER!
24:53
Artisan Electrics
Рет қаралды 35 М.
5 Deadly Hidden Electrical Faults
23:56
Artisan Electrics
Рет қаралды 103 М.
Electricians Day Inspection and Testing of Electrical Installations
35:57
Artisan Electrics
Рет қаралды 41 М.
Cost of a rewire in the UK
14:25
N Bundy Electrical
Рет қаралды 129 М.
WORKING IN TIGHT SPACES - Electrician Life
23:49
Artisan Electrics
Рет қаралды 67 М.
Installing an AFDD Consumer Unit in a Garden Shed - Electrician Life
43:00
Artisan Electrics
Рет қаралды 168 М.
THE IMPOSSIBLE FAULT FIND - Electrician Life
25:04
Artisan Electrics
Рет қаралды 70 М.
Electricians Day Installing Google Nest Smart Home Products
27:47
Artisan Electrics
Рет қаралды 85 М.
Why I Hate Emergency Fault Finding Jobs - Electrician Life
22:12
Artisan Electrics
Рет қаралды 188 М.
How Iron Ore Mining Works!
15:31
Aaron Witt
Рет қаралды 40 М.
ЭТО НАСТОЯЩАЯ МАГИЯ😬😬😬
00:19
Chapitosiki
Рет қаралды 3,6 МЛН