Hi, I have a query regarding the selec vprd2m voltage protection relay that I recently purchased. My house has a single-phase 2-pole setup, and I intend to use the vprd2m relay with it. However, the relay's output is 5 amps, and my house has a mix of resistive and inductive loads ranging from 5 amps to 15 amps. To handle the varying load, I am considering using a 2-pole or 3-pole 25 amp contactor in conjunction with the vprd2m relay. This should help manage the load more effectively. Currently, I'm facing an issue where the vprd2m relay becomes excessively hot whenever my house appliances' load increases beyond 5 amps, especially when it reaches 12+ amps. Could you kindly suggest a suitable contactor that can handle loads from 5+ amps up to 15 amps for my 110v - 300v, 20 - 25 amp resistive + inductive load setup? I'm looking for an affordable yet reliable option that won't compromise on safety and performance. Your expert advice on this matter would be greatly appreciated. Thank you in advance for your help!
@onlineelectricwork Жыл бұрын
use 60 amps magnetic contactor with protection device and connect all load through contactor. protection device will operate the contactor only and all load on magnetic contactor.
@freedom_fighter- Жыл бұрын
@@onlineelectricwork could you please suggest schiender model number, what about coil voltage ..
@freedom_fighter- Жыл бұрын
@@onlineelectricwork Vprd2m specification / datasheet are as follow. Vprd2m voltage monitor realy's Operating voltage might contactor coil voltage ( vprd2m Operating Voltage 127 to 288V AC) How much contactor's coil voltage I supposed to choose. ? Type of Output 2 C/O (DPDT) Output Specifications No. of Relays 1 Contact Rating NO, NC : 5A@250V Auxiliary Supply Specifications Supply Voltage Self Powered Nominal Input Voltage, Un 230V AC (L - N), Operating Voltage 127 to 288V AC (L - N), VA Rating 5VA max, Frequency 48 - 63Hz
@onlineelectricwork Жыл бұрын
@@freedom_fighter- anyone schneider or ABB model.if you have use 110 voltage for single phase power supply so contactor coil voltage shall be 110v otherwise 220v
@onlineelectricwork Жыл бұрын
@@freedom_fighter- contactor coil voltage =220v
@WaheedKhan-uu6jm2 ай бұрын
Very in explain
@haqbadshahsarkar786Ай бұрын
Bhai jaan 3 pole connector k connection b bta den please
@onlineelectricworkАй бұрын
merey channel ka visit kren wahan mil jay gi video
@electricpoint8147 ай бұрын
Bhi ya waley app hum mobil par be chala saktay hey ya ni
@onlineelectricwork7 ай бұрын
No idea
@NomanKhan-es5qu6 ай бұрын
Is ko direct chalana ho kia kare gay ,, Neotal phase Dena ho to
@onlineelectricwork6 ай бұрын
is ko direct chalana ho to neutral or phase sy direct magnet contactor ki coil ko ON krwayen gy
@ShahrozahmadAhmad-g2o4 ай бұрын
Good
@ronalddsouza82702 ай бұрын
Neutral ko common me dalnegea haiina, compressor me
@onlineelectricwork2 ай бұрын
neutral ko common me lga den ya phase ko ek hi bt hy.
@MdAliraj-vd4cd7 ай бұрын
Zazak allah bahut acha laga hai
@Pradeshikanxo-p4y4 ай бұрын
goor bro
@ateseteknik6216 ай бұрын
Please making this shema for inverter
@nrnayonahmed7318 ай бұрын
Nice...
@ArtA1TVchannel5 ай бұрын
Sir dc inverter mein bhi capacitor hota h?
@onlineelectricwork5 ай бұрын
capacitor to hota hy lekin kit k ander hi built-in hota hy
@ArtA1TVchannel5 ай бұрын
@@onlineelectricwork mera kenwood ac e comfort pro ampere drop nahe krta kia waja ho sakti h?
@technicalchannel92603 ай бұрын
👍👍
@MDDILSHADMALIK-k7v3 ай бұрын
👍🏻👍🏻👍🏻👍🏻👍🏻👍🏻
@sohailhafeez1175 Жыл бұрын
nice video liken Bhai jes AC ke man outdor ma ho indoor ke us ke wring pa asa he bna da video
@onlineelectricwork Жыл бұрын
ok
@abdalqadr14 ай бұрын
❤❤❤❤❤❤تمام
@Attaullah-v3oАй бұрын
❤❤❤❤❤🎉
@mohammeddulalmiah7 ай бұрын
Thanks br
@satishbhanang30648 ай бұрын
Sir outdoor thodi der chlta bad me off ho jata ha please sugg
@onlineelectricwork8 ай бұрын
1=outdoor fan ki speed ko check kren km ho gai hy to capacitor check kren. 2=outdoor ka condunser check kren or sfai kren