No video

Split Cylinder Testing (ASTM C496)

  Рет қаралды 119,325

Matt OReilly

Matt OReilly

Күн бұрын

Performing a split cylinder test on a 6x12 cylinder in accordance with ASTM C496.

Пікірлер: 37
@foxopossum
@foxopossum 5 жыл бұрын
Love this guy’s videos
@ozanergul6000
@ozanergul6000 3 жыл бұрын
nice shorts
@rogso6581
@rogso6581 Жыл бұрын
Rate seemed too fast
@chandrashekharlakavath8748
@chandrashekharlakavath8748 5 жыл бұрын
Hi matt Oreilly, What is the rate of loading of split tensile test...?
@oe3lab
@oe3lab 11 ай бұрын
100 to 200 psi/min [0.7 to 1.4 MPa/min]
@abasalhussain4072
@abasalhussain4072 7 жыл бұрын
can you tell us the basic concept of this test while we are applying compression load to find tensile strength please?
@syednajamulsaqib7664
@syednajamulsaqib7664 3 жыл бұрын
@I know Cause I'm BatMan. exactly this happens due to poisson effect.
@echpee
@echpee 2 жыл бұрын
We are applying compression in the vertical direction but the cylinder will undergo tension along the length.
@AjayKumar-og6dp
@AjayKumar-og6dp 4 жыл бұрын
Could you tell me your specimen height and dia. As far as i know i heard the dia probably 6 inch but i didn't know the height so tell me ?
@Vizzini13906
@Vizzini13906 4 жыл бұрын
12 inch, most likely for a 2:1 ratio
@tinakumbhare3231
@tinakumbhare3231 5 жыл бұрын
thanx alot
@belalhossain5878
@belalhossain5878 5 жыл бұрын
can i test the compressive machine? what type of instrument need the test please
@rodriggoadolfo
@rodriggoadolfo 8 жыл бұрын
the wood fringe ought be longer or equal to the cylinder.
@MurphysColesLaw
@MurphysColesLaw 8 жыл бұрын
+Rodrigo Adolfo You are correct (and I do state as such in the video); when I made this video, I was a bit pressed for time and made do with what I had. One of these days, I'll go back and rerecord it and introduce a new series of mistakes :) .
@abubakarmohammed1633
@abubakarmohammed1633 8 жыл бұрын
I appreciate.
@tengrenwei7684
@tengrenwei7684 7 жыл бұрын
What is ur mix proportion for the cylinder?
@italouruguayricano
@italouruguayricano 9 жыл бұрын
I have done this test after treating the concrete with different conditions to see which treatment improves the concrete.
@pauljohnbaybay1099
@pauljohnbaybay1099 4 жыл бұрын
what was the result sir? in numbers.
@arpitshukla9516
@arpitshukla9516 7 жыл бұрын
Maniac
@chadrigwapo
@chadrigwapo 9 жыл бұрын
is this the same as shear test?
@BiniMerina
@BiniMerina 10 жыл бұрын
what is the practical use of this test?
@Binybini
@Binybini 9 жыл бұрын
***** practically there is no such type of loading in the real environment. for example if you take compression and flexural strength testing for concrete, you can find the type of loading in the actual structure. so that you can use the result for decision purpose. to me the test is neither tension nor compression. to assume it is tension test the whole part(body) of the concrete should be in tension force. as you see here the force is applied in a line wise.
@Kamikorosu0416
@Kamikorosu0416 8 жыл бұрын
can someone tell me the practical use of this test and significance in real world? how do this differ from pure tension? please answer. need for research. thank you!
@angelmusonda7951
@angelmusonda7951 6 жыл бұрын
The test is an indirect way of determining the tensile strength of concrete since direct methods are somewhat difficult.
@belalhossain5878
@belalhossain5878 5 жыл бұрын
can I test the compressive machine beside would instrument name of the test
@udeshakasthuriarachchi8101
@udeshakasthuriarachchi8101 2 жыл бұрын
i also want to know if compressive machine can be use
@hollowtheone
@hollowtheone 8 жыл бұрын
Can we do the split test using 4x8 cylinder???
@MurphysColesLaw
@MurphysColesLaw 8 жыл бұрын
Yes, unless your aggregate size is larger than allowed for a 4x8.
@donrebsagadguevarra687
@donrebsagadguevarra687 8 жыл бұрын
cylinder size should be 3 times the aggregate size
@SallySlayer409
@SallySlayer409 8 жыл бұрын
According to ASTM you are supposed to average two measurements of length.
@AjayKumar-og6dp
@AjayKumar-og6dp 4 жыл бұрын
Buddy carefully your finger stock in there
@Bellushaie
@Bellushaie 8 жыл бұрын
could i ask at what rate was the load applied?
@MurphysColesLaw
@MurphysColesLaw 8 жыл бұрын
+Baldeep Bhullar The ASTM calls for 100 to 200 psi/min, which works out to a load of about 150-300 lb/second.
@Bellushaie
@Bellushaie 8 жыл бұрын
+Matt OReilly Thank you for your prompt response Matt. Cheers!
@iitgkaladka1888
@iitgkaladka1888 3 жыл бұрын
Your name reminds me of maddy o reilly
@gesyukushibatasou-mansion
@gesyukushibatasou-mansion 3 жыл бұрын
私たちの見てくれませんか (12) A NEW IDEA CONCRETE number 1 - KZbin
Preparing and testing concrete cylinders
11:23
Matt OReilly
Рет қаралды 47 М.
ACI Strength - ASTM C39 & C1231 Compressive Strength & Unbonded Caps - CRMCA Accessible Procedures
6:39
CRMCA (Colorado Ready Mixed Concrete Association)
Рет қаралды 18 М.
Happy birthday to you by Tsuriki Show
00:12
Tsuriki Show
Рет қаралды 12 МЛН
ISSEI & yellow girl 💛
00:33
ISSEI / いっせい
Рет қаралды 25 МЛН
Professionally Refurbished 2022 Bizerba GSP H Manual Slicer
3:46
BP Kitchen Equipment
Рет қаралды 1
Expt 6.  Static Modulus of Elasticity of Concrete in Compression
7:31
Preparing and testing concrete cylinders (ASTM C39)
13:19
Matt OReilly
Рет қаралды 62 М.
Direct Tensile Strength Test
7:52
Civil and Environmental Engineering, School of Mining and Petroleum Engineering
Рет қаралды 4,1 М.
How to do Concrete Cube Test at Construction Site
11:59
Civil Engineering Bitz!!
Рет қаралды 173 М.
Split Cylinder Testing of Steel Fiber Reinforced Concrete
12:16
SPLIT TENSILE OF CONCRETE
2:36
Mohan A
Рет қаралды 21 М.
How to determine flexural strength test of concrete || Laboratory Concrete Test #3
4:36
Anime_Edu - Civil Engineering Videos
Рет қаралды 193 М.
ASTM C39 2015
16:13
james Lee
Рет қаралды 86 М.