Is a PVB adequate backflow prevention?. RPZs are mandatory in our area
@stefanjairrobalino30665 ай бұрын
What if main line from city is copper ?
@AlabanzasyAdoración7 Жыл бұрын
If my line supply is 3/4 my back flow preventer has to be the same or can it be 1"?
@AlabanzasyAdoración7 Жыл бұрын
If my line supply is 3/4 do my lines to my zones have to be the same or can they be 1"?
@logansneed28822 жыл бұрын
Makes my skin crawl to see the above ground back flow, I’m a young guy and wasn’t taught like that! That’s the new way.
@robertlam55072 жыл бұрын
Where do you out the backflow?
@logansneed28822 жыл бұрын
@@robertlam5507 Tap it off the water meter and bury it in a box, I dont understand why people put it above the ground on the side of the home.
@robertlam55072 жыл бұрын
Here in Illinois we cannot use PVB’s we have to use RPz backflows. The cannot be buried under ground. They can be out in a basement or a boiler room. If you install a RPz indoors it must have a drain pipe below the dump at least 11/2 times the size of the RPz backflow. We are not allowed to use “douable check valves either. I think every state has it’s own codes.
@logansneed28822 жыл бұрын
@@robertlam5507 Probably so, in some states do you have to have a plumbing license?
@robertlam55072 жыл бұрын
@@logansneed2882 yes. In Illinois it takes a licensed plumber to install and test them. In Missouri I have a license to test and repair them. The unions in Chicago set the rules for Illinois and keep us Irrigation guys from testing.
@docham3 жыл бұрын
VERY IMPORTANT to open the downstream Backflow Preventer valve SLOWLY.
@luernesto744 жыл бұрын
Im looking for the shutoff valve to the sprinklers but i can't find it! Where could it be?
@francej97544 жыл бұрын
Where ever the previous owner put it 😂 if they didn’t mark it or put a cover on it just have to back track the sprinkler system and locate it. Big headache
@Jehucurliss2kings4 жыл бұрын
Usually by meter or house. Inntx usually underground in box. Usually near water meter (best) or house (amateur).
@Jehucurliss2kings4 жыл бұрын
In tx usually underground. Not a pvb but a dca. Usually in a box. Sometimes no backflow preventer at all. When illegal is ok......illegal is what you get.
@roberturibe29883 жыл бұрын
What size pvc they using? 3/4? Schedule 40?
@keystoneplumber3 жыл бұрын
They said 1 inch
@robertlam55072 жыл бұрын
Why do you not put unions on the PVB so that they can be taken off for the winter? What a waste of time and money to wrap insulation around the pipes. Also why not put a ball valve on the upleg pipe so you can shut it off at the backflow in case you have to replace it?
@bygonebob Жыл бұрын
I agree with the unions. Exposed pipes (above ground) and capped off will break when the water inside freezes and expands, so it needs to be wrapped. In the video, it showed a shut-off valve was installed right after it teed off the main line in case you've missed it.
@Jehucurliss2kings4 жыл бұрын
Ya. Everyone seems to think that 1 inch main is way to go. Many times , if large residential and or low pressure - Good idea to go 1-1/4 inch sometimes. Or even larger depending on meter size. This one size fits all is getting old.
@noeeon99104 жыл бұрын
1" usually does the job, I hardly ever see the reason to go above 11/4" 11/2" hardley improves your pressure but cost more and is harder to work with.
@Jehucurliss2kings4 жыл бұрын
@@noeeon9910 Hardly improves your pressure? I've done repairs on hundreds of systems. Bad advice
@noeeon99104 жыл бұрын
@@Jehucurliss2kings I'm a licensed irrigator and licensed backflow tester. You done hundreds? I've done thousands... the amount of friction loss that happens in a 11/2 pipe is not that much of a drop from 11/4 look it up on your pressure loss charts if you know what those are. Therefore the benefits of using 11/2 aren't many...
@Jehucurliss2kings4 жыл бұрын
@@noeeon9910 Have you ever designed a commercial system ?
@Jehucurliss2kings4 жыл бұрын
I see now that your main point was pressure loss between 1 1/4 and 1 1/2. My main point of disagreement was your statement that 1" usually works. Depends on size of system.