You're the first person to actually explain what static pressure is clearly. Thank you.
@HomePerformance3 жыл бұрын
High praise- thanks man
@G04524 жыл бұрын
I've been doing research on static pressure to understand it better, and this is the best video I've seen on the subject. Highly recommended to HVAC people.
@HomePerformance4 жыл бұрын
Hey, thanks David! Nice to hear!
@MrDavidla663 жыл бұрын
Same here & I agree!
@HomePerformance3 жыл бұрын
Thank you other David!
@usamaasif1812 Жыл бұрын
Great for non hvac professional too
@JoseRodriguez-kx9gz4 ай бұрын
Can the testo be use without the probes.
@timwright87715 жыл бұрын
Such a great video of clearly explaining static Pressure. We get static pressure readings on every call our techs go on. Keep up the great work!
@raindogs451 Жыл бұрын
33 year HVAC guy, who started in Air Balance for 3 years. Your videos rock, and you're an effective communicator. I've attended many classes with brilliant instructors who couldn't instruct. That's not you.
@HomePerformance Жыл бұрын
WOW, thanks a lot my man! Really appreciate it! You know I get trolled for this stuff sometimes too, so it’s nice to hear the opposite.
@yozy49962 жыл бұрын
This guy does the best Tutorial I've ever experience, and I have been watching him for a good while...
@HomePerformance2 жыл бұрын
Aw, geez, thanks Yozy!
@ParabellumX Жыл бұрын
I paid thousands of dollars to go to college for HVACR in order to become an HVACR Technician, and my instructor didn't teach us any of this. We either learned (almost) everything from an online educational program (Cengage Learning) or our book. Our teacher often took days off in order to go fishing. I'm pissed; I learned more from this guy about static pressure (and other sections of HVACR from other people here on KZbin) than I have from my 'teacher'. 🤬🤬🤬 Thank you, Corbett. I actually just watched this video about five times back-to-back. After all, repetition is the basis of all teaching. 😏
@HomePerformance Жыл бұрын
Hey man, sorry to hear. I suspect your experience is not uncommon.
@ParabellumX Жыл бұрын
@@HomePerformance I agree. I think the teachers' philosophy at school is, "We're just giving you enough to get you started. If you really want it bad enough, you'll go get it." And that alone cost $10,000. Next time, I'll just rely on Google and KZbin, and treat myself to another brand new bike.
@30rdmaga3 ай бұрын
@@ParabellumXdefinitely not uncommon it's crazy how little real life education you get from these schools
@Absolute_Service10 ай бұрын
Well done SIMPLE video. We use this in our training (for a few years now) when we are onboarding new team members. Thanks for the content, keep it coming brother.
@HomePerformance10 ай бұрын
Hell yeah man, thanks for the high five!
@LouisWilen2 жыл бұрын
There are a lot of videos and web sites that address static pressure. This video is the best of all of them.
@HomePerformance2 жыл бұрын
Damn, Louis! Thank you buddy.
@MrCesaraquino8 жыл бұрын
I've been searching for a good static pressure explanation video all over KZbin and none of them are as thorough and precise as yours has been! Thanks for taking the time to explain this procedure step by step.
@HomePerformance8 жыл бұрын
So glad it helps you, +Cesar Aquino !
@JAMR07167 жыл бұрын
helped me too. thanks!
@HomePerformance7 жыл бұрын
+Jose Marcano glad it helped!
@GrumblesM45 жыл бұрын
Home Performance hey so is a wet coil .07? Or is that dry?
@HomePerformance5 жыл бұрын
Def dry
@mikemartinez86148 жыл бұрын
My instructor gave us topics to research before discussing it, and static pressure is one of them. This cleared up a WHOLE LOT for me! Great explanation! Thank you!
@HomePerformance8 жыл бұрын
+mike martinez wonderful! So glad to have helped.
@wayneschneyer86993 жыл бұрын
As a retired service and training manager for a major brand and an instructor of manual J & D, I ground your video to be excellent, correct, and very well explained. Great job! Airflow and air duct testing is so important as many system failures are traceable back to a faulty duct system. A “ tip” if I may. When drilling into a furnace or air handler beware that there’s insulation ( in many cases) that’s only glued on and any excess pressure from the drill may loosen the insulation causing an eventual failure of adhesion allowing the insulation to start flopping around with some ending up on the evaporator coil. Another way, on furnaces, would be to remove the high limit and go in there. You’ll be between heat exchanger cells right above the blower and get a accurate reading too. This way you will not damage the insulation. Just of course be aware that one leg on the limit is hot with 24 volts, so as not to blow the fuse on the board. Real bummer 😖 This video has very valuable information guys, please use it.
@HomePerformance3 жыл бұрын
Thanks Wayne! And yes, limit switch hole is better than nothing, but the reading obtained there will be higher than actual. If they can pass ESP with that spot, great, but in my experience installers need every 0.1” wc they can get to be at .54” and round down.
@darriuscole8544 Жыл бұрын
@@HomePerformance - What is the best way to deal with the holes after you have run all the tests?
@HomePerformance Жыл бұрын
@darriuscole8544 they make metal plugs, or plastic if you prefer.
@danielgump83873 ай бұрын
This is invaluable… I want to incorporate this because very few tradesman take this into consideration in the field, and comfort problems are the hardest things for me to solve. I can fix anything that’s broken but when it comes to humidity issues and the refrigerant levels look good… oh boy I start scratching my head
@williamkrauk8935 жыл бұрын
First: thank you for the descriptive and informative video.it was very helpful. I have been doing hvac for 30 years and believe it or not I never considered evaluating static pressures. UNTIL one day I did a change out and removed a zoned damper system including the bypass per customers request and was unable to get my subcooling or super heat correct. It was a nightmare. I called the manufacturer technician support and discovered just how important static pressure truly is. It's not enough just to replace a system without verifying that the ductwork was seized correctly. Now I ALWAYS check static pressures on every job including surveys for new accounts. Be safe everyone
@HomePerformance5 жыл бұрын
Keep on rocking, William!
@ocdmods49923 жыл бұрын
Thank you. Finally a Static Pressure video that was clear and concise. Answered all the questions that i should have already known the answers to.
@HomePerformance3 жыл бұрын
Hey, great to hear- thanks!
@amnerayalacastaneda20094 жыл бұрын
Nice! I'm an HVAC student and its been a while since my first class. This material is refreshing. Thank you.
@HomePerformance4 жыл бұрын
That’s great- glad you found us. Hope you subscribe and find all our other stuff too!
@danslickers8166 Жыл бұрын
Greetings Just wanted to let you know that I appreciate the video’s you make. I’m sure you get push back from businesses that, in reality, should be thanking you for the information you provide but instead “they” just want things how “they” want them and not to be checked or questioned. Please don’t get discouraged. Just keep on keeping on. Know that you have thousands of guys that appreciate knowing how things are supposed to be. Hope you and your family are well. Grace and Peace Slick
@HomePerformance Жыл бұрын
Hey, thanks Slick- very thoughtful of you to take the time, and always nice to hear.
@bobbrown83613 жыл бұрын
Much better explanations and demonstration for the layman than most other videos 👍😎
@HomePerformance3 жыл бұрын
Thanks Bob buddy
@TheSlim2none2 жыл бұрын
Wow think I might actually understand it now. This was much better explanation than others teachings.
@HomePerformance2 жыл бұрын
Awesome Chris!
@RGfixitright2 жыл бұрын
Well explained and after watching several times and mapping my system which is different than most, I finally understand the pressures and meanings. Thanks.
@michaelbyron11662 жыл бұрын
That is the best explanation of this subject that I have heard. Thank you for sharing this excellent video.
@HomePerformance2 жыл бұрын
Hey, thanks do much Michael! Happy to hear- hope you’ll dubscribe, lots more where this came from.
@Balticblue932 жыл бұрын
If you study anything from ACCA, you will know now in 2022 with the Air handlers, furnaces and package units, the static pressures can exceed 0.5 without causing any issues. Is it ideal to be 0.5 or below, sure I suppose so. But I have seen systems run just fine at 0.9-1.1 without an issue. Variable speed ECM blowers were practically designed for that. But a properly built system with the right amount of return air, a large filtration system 4-6" filters with good air flow, a good variable speed system properly matched with the ducting design and system functions with be most likely below 0.5 but can safely run much higher. For the homes that are completely finished, and ducting cannot be upgraded, the HVAC system can still be spec'ed properly that could be running 0.5-0.9 without a single hiccup. There are just too many variables to say 0.5 is the maximum these days, but this is a 6-7-year-old video and the 80%-98% units have come a long-ways. This is an outdated video but still has some validity for older systems. Like, don't put in a Filtrete 1900 1" in a single stage 20-year-old 80% system, sure you will have problems. But anything with an ECM blower will run fine but I still don't recommend that ridiculous filter. But also, stop putting on those no MERV rated filters that you can see through that cannot even stop flour. Depending, a MERV 8 is a good average for older systems. If you want to pay a $1 a filter and change it monthly with very little filtration, so be it. It is your stuff, but a MERV 5-6 would be fine for that use. Anyone can add a 5" filtration box to their system and have reduced static pressure and better filtration, no matter what year it was built. Just make sure you have good return air, good intake air and generally you will have a pretty healthy system, if serviced yearly and cleaned properly on your coil, condenser and blower. Maintenance is just like a car, after all, they do cost as much to replace! But these days, you can get some amazing systems for a decent price. I sell my clients the best system possible at the best price. Find a small HVAC company that has good reviews, and you will get better service than some big-name company who advertises on TV or mailers. You get to pay for all their advertising, fancy vans/trucks etc. Make sure they do a full manual J, S and D and get 4-5 quotes and ask neighbors and friends on social media for referrals to friends and family. I promise, if you follow some of these rules, you will have success and be happy. Have a great day!!
@youtubereview81765 ай бұрын
What is the location of where you work? I'm sure people reading your comment might be interested in your HVAC services.
@wojtek-334 ай бұрын
How would one go about replacing a 1in filter box in the ceiling with a 5in? They dont seem to exist or i'm just not looking in the right place.
@HomePerformance4 ай бұрын
@wojtek-33 you can get a 4” Aprilaire I know
@Balticblue934 ай бұрын
@@wojtek-33 Do you mean your furnace or AHU is in the attic? You can buy Honeywell, AprilAire, Trion Bear and many other filter boxes. Or are you talking about return air ducts. You can buy filters that have a lip and the filter extends up into the cavity. One brand is Flow Right. And you get get filters at Filterbuy in the custom sizes. So many options available but I am not sure of your setup.
@wojtek-334 ай бұрын
@@Balticblue93 yeah I'm Texas and a lot of homes have the whole system in the unfinished attic with a ceiling filter box in the living space. Of course mine is on a 10ft ceiling so need a ladder to change. It's a pain and it's an odd 24x36. Just found the ones with the lip but they are pretty expensive and almost none for my size. I look into one of the replacement boxes after taking some measurements on my system, maybe it's fine.
@بوفارسبونورا-ص7ه6 жыл бұрын
Well done 👏 The pressure drop of coil + filter called internal static pressure . The pressure drop of the duct called external static ptessure .
@yamazaheer69664 жыл бұрын
You are very good at explaining and your teaching is very straight forward and easy to understand, thank you very much
@HomePerformance4 жыл бұрын
So glad to hear, Yama Zaheer
@manismello6 жыл бұрын
Corbett, This is a rare find! A superior instructional tool... Thank you much!
@HomePerformance6 жыл бұрын
Thanks for enjoying it, Romell!
@frankgall65 жыл бұрын
Anyone else notice how nice that install is.
@bobpaulino47144 жыл бұрын
Nice video. Very true that most don't check sp. Got a kick out of the 'giant fan' comment! I travelled 9 states for an institutional and industrial sheet metal company living out of a service truck and suitcase. Crane and helicopter picks to get equipment on to rooftops and equipment suites. You could actually crawl into the fans I worked with and pretend you were a gerbil if you were so inclined. Our systems that were designed during the tuberculosis period were set up to bring in 100% outside air, heat it, deliver it to the rooms, and then exhaust it through big vents on the roof. In the 80's and 90's we spent days with saws, Jack hammers, drills, the infamous, back breaking 'wacker', and hammers and chisels opening up primary return air chases, and individual room chases to provide return air - and required smoke and fire dampers. There were variable pitch sheaves and vortex dampers to adjust volume (often upgraded from wooden sheaves and flat belts) Million+ btu burners, oil nozzles (sometimes triplex) that drank gallons per hour, even coal stokers (ever had to clear a coal room to get to an auger's shear pin?), early geo- well water circulated through cooling coils, enormous compressors for DX or chillers, huge pneumatic or motorized outside air, mixing, and exhaust dampers, Chai pull, pneumatic, and now ddc controls, and single draft inducer bearings at power plants that weigh more than an entire residential furnace and dx cooling system combined. Had two boilers in a school in Ashtabula ohio that had come OUT of a great lakes steamer in the 1930's. Had to convert them to gas. The last boiler man in the district that knew anything about coal was retiring-- had that scenario at schools all over as coal was being phased out. Remember back in the 80's when one of our sheet metal guys dropped a tinners hammer from a catwalk from duct big enough to drive through at the Ohio Theater in columbus ohio. Just missed the organ. I was often serenaded by Dennis James on their 'Mighty Morton' while performing pm there (35' × 16' filter area with electronic cells and automatic static pressure controlled feed for oiled prefilter rolls {talk about an itchy job!!}) The low notes on that organ would make your innards quiver like the bass guitarist Chris Squire's low notes in Yes's Starship Trooper!! We subcontracted companies that came in to confirm the balance numbers that our engineers had come up with. Our company had been founded in 1867. After merging with a pipe fitting company it took less than 3 years for the new rape and run business model to run it into the ground. They didn't like that I objected to their business approach. Have worked on that little stuff from time to time-- got cut on one of those itsy bitsy zip screw points or a rough cut sliver of metal just about every time I had to try to squeeze my hands into that stuff or work around that light gauge (aluminum foil!!) duct! Lol. Put some give a damn in your work and you'll build friendships that last a lifetime. Was a great trade.
@jamesedwards5931 Жыл бұрын
You got it right! The .59 TESP should and does total your other 4 SP readings. SA duct -.07, Coil - .14, Filter -.19, RA duct -.19 = .59 TESP. As you mentioned, the other readings clearly show where the problem of too high TESP is. Thanks
@staticpressurenerd51823 жыл бұрын
Great presentation. This helped me get more involved in air flow testing a few years ago. Hence to name, static pressure nerd. I would be interested to see the pressure drops in the return drop!
@HomePerformance3 жыл бұрын
Love it! Thanks my friend! More testing courses coming up, both in person and virtual: BuildingPerformanceWorkshop.com
@ramchillarege16584 жыл бұрын
Great Video. You are a gifted speaker and teacher.
@HomePerformance4 жыл бұрын
Thanks very much, my friend
@rodgraff17825 жыл бұрын
We always did static pressure, temperature rise and gas pressure tests on all of our start ups, then recorded the readings and put them in a customer file. If you don’t do this you are not determining if the furnace is running properly and under design conditions
@mason122122goodman5 жыл бұрын
We do it on every start up, every single maintenance just to ensure the system is operating properly and nothing has changed within the system. I love it
@HomePerformance5 жыл бұрын
My hero
@rodgraff17825 жыл бұрын
Keel up the good work!
@bfironside93272 күн бұрын
As an HVAC tech I always put the ac coil 6" above the furnace
@HomePerformance2 күн бұрын
Good work buddy
@nathanperney72858 жыл бұрын
Great video. Thankfully it confirms they way I test static. That is typically ow I test TESP. One slight difference I usually pullout the high limit switch to get the post-blower pre-coil number.
@HomePerformance8 жыл бұрын
Thanks, Nate! The high limit switch is not ideal- you get a higher than actual TESP. You will pick up some of the pressure induced by the top half of the heat exchanger- which they do not want you to include in the TESP.
@nathanperney72858 жыл бұрын
I conformed that in our shop with a live unit. Its a pretty consistent .18-2 higher in the heat exchanger.
@kamalhassan1837 жыл бұрын
Great work Corbett, one simple line from you cleared up my head. Thanks.
@HomePerformance7 жыл бұрын
+Kamal Hassan so glad to hear!
@chrisspanyer1525 Жыл бұрын
Best video for furnace system. Would be awesome if you did a video for heat pump systems. Thanks for through easy to understand video.
@HomePerformance Жыл бұрын
Thanks Chris, I’ve added it to the list.
@NatetheHouseWhisperer8 жыл бұрын
Awesome! By far the most clear explanation of static pressure I've seen! It's been a while for me and I need to do it next week, so I appreciate the refresher! A few notes: 1. That is a quiet AHU, I couldn't hear it in the video! 2. Don't forget the low limit for TESP, 0.08" WC. I've been finding 0.12" is the bottom on some systems - the second floor doesn't cool for squat below that. 3. The positive/negative thing still messes with me. (I'm a little slow sometimes...) Perhaps talk about the difference or spread between the two? The spread -.38 and +.21 is .59. Like I said, I'm a bit slow sometimes... Thanks again for the refresher, I get to freak out once again while I drill holes in a perfectly good furnace next week!
@HomePerformance8 жыл бұрын
+Energy Smart Home Performance glad to help my friend. Easiest way to calc the spread is just drop the neg sign at the get-go and add the two together.
@stephenweller564 жыл бұрын
Thank you for putting so much effort into what is probably the best and most informative KZbin video of its type. Bravo! And guess what. There's no pre-drilled hole in my system!
@HomePerformance4 жыл бұрын
Ha, thank you Stephen, and glad to hear you’ll be installing the first ever test port in your system!
@flooftoes7 жыл бұрын
Very clear demonstration, thanks for posting. I've just determined that my furnace (which was installed by previous owner in 2012) is staved for return air. I found that the heat limit switch was tripping every time the system was kicked into 2nd stage heat. When I remove the panel before the blower the limit switch doesn't trip -- I posit that this allows enough airflow to keep the furnace in operating temperature range. I think the installers never fully tested their installation and now I have to figure out how to solve this inadequate return issue for them. My furnace installation does not have any of the ports you called out as needed in order to make TESP measurements.
@HomePerformance7 жыл бұрын
Excellent diagnostic work, Greg!!! Once enough homeowners are like you, the HVAC industry will be a different beast!
@stevewiggins11676 жыл бұрын
Thanks, I learned something and I've been doing a/c for 25 years...
@HomePerformance6 жыл бұрын
Awesome! Thanks for watching and commenting, Steve!
@heatncool4 жыл бұрын
I know isn't it crazy how slow the growth is working for someone compared when going out on your own. Thats why I'm out here learning a few things, my employer refrained from me to keep me from fully independent lol well here I come! 😂
@StephenRardon8 жыл бұрын
Absolutely fantastic explanation! Love it!
@HomePerformance8 жыл бұрын
Thanks +Stephen!
@IshockO8 жыл бұрын
Stephen Rardon hey Stephen can bad total static pressures cause adnormal refrigerant pressures?
@StephenRardon8 жыл бұрын
IMon Airflow does effect refrigerant pressures, in my opinion "bad static" is high static which means poor Airflow
@HomePerformance8 жыл бұрын
To clarify, all A/C is just refrigerant and airflows. The refrigerant PERFORMANCE is affected by airflow, but the pressures in the lines and the ducts don't talk directly to each other.
@dennisnoone74276 жыл бұрын
Always thought the probes need to go with the airflow for accurate readings, what are thoughts Steve?
@sargamites3 жыл бұрын
Super clear & enthusiastic presentation!
@HomePerformance3 жыл бұрын
Thanks man!
@hvac014537 жыл бұрын
very good descriptions in common language that help visualize airflow...
@HomePerformance7 жыл бұрын
+hvac01453 so glad you liked it!
@1guysmilely5 жыл бұрын
Ok so after I get static pressure reading? What do I do with that info? Is there something to adjust if we are low or high on static pressure? I guess you would want to check airflow before adding refrigerant.
@HomePerformance5 жыл бұрын
It’s a forensic look at whether the ducts were designed properly, and if you have problems in one particular area. Surgery would be required generally.
@hvacprofessor42218 жыл бұрын
I have been doing this for years in the memphis area, I am not only a contractor, but an Instructor at a tech school as well. I try to teach my students these principles to commission units and use a blower performance chart to set proper airflow for A/C. The sad part is the majority of homes run .8 or higher. Those 1" pleated filters are horrible for static. I recommend nothing less than a 2" pleated for single filters at the furnace base. Jack Rise from ACCA taught a class here years ago and called Memphis the land of no return. He was right! After seeing very nice homes with 2x4x16" wall stacks and builders trying to get 2 tons of return in two cavities! The installers in the area have no clue, the builders want the cheapest, and the homebuyers say look at the granite countertops and saltwater inground pool. Next thing I'm telling them the ductwork was done by a doofus because they aren't comfortable.Keep educating! I just replaced a 7 year old system on a new house because the plenum had a 4"x22" hole in it in the attic where it was never sealed! Keep calling out the shoddy work! It's not opinion if there is verifiable performance! Oh, sometimes I can't drill an old furnace in a closet, I normally take out the limit switch for my probe, not ideal, but works!
@HomePerformance8 жыл бұрын
+Jesse Johnson you rock brother. Keep up the great work in TN- the world needs you calling out doofus work! See you around I hope- we're not far, in Atlanta now!
@HomePerformance8 жыл бұрын
PS +Jesse Johnson : my 6-week mastermind course might be useful to your students or colleagues HomePerformance.training Starts 4/1 and registration begins 3/1
@jones450ktm6 жыл бұрын
Jesse Johnson I'm in Nashville and I see a lot of the same. I actually got cussed out the other day by another inspector of all people because I wrote up a 5 ton system pulling from one 20x30 return filter and a 10x15 run. The static pressure on the return alone exceeded .5" which is the max on the system allowance. You just have to walk away and shake your head at some people.
@tommyteamer9037 Жыл бұрын
You tart how to test that furnace really good and I thank you for that.
@HomePerformance Жыл бұрын
Tanks Tommy
@ciclotan2 жыл бұрын
I may be misunderstanding what you're saying at 9:20: in this setup it appears that the filter is After the furnace blower fan. Shouldn't the filter be on the suction side of the blower fan?
@rickyry15835 жыл бұрын
Great video! Thanks for educating! It made all the pieces fall into place! Sometime a video makes sense when the books dont!
@biblebloopers9462 жыл бұрын
So how do you know what the pressure drop is supposed to be across an evaporator coil if it is not part of the furnace itself? Also how do you know what the pressure drop across any filter should be?
@HomePerformance2 жыл бұрын
Manufacturers put that info in the install manual, for both coils and filters.
@DayClanTribe7 жыл бұрын
I agree with so many others on here that this was one of the best, easy to understand explanations and demonstrations for basic testing of static pressure with some great references to industry standard measurements such as drop across filter and A-coil etc. Thanks for sharing! I'm actually trying to determine airflow in CFM for my 3-ton heat pump system to see if it is meeting the required 400cfm per ton which would be a total of 1200cfm to work properly & efficiently. I'm finding that determining airflow accurately without expensive testing equipment can be a very difficult thing. And the results of low cost instruments can vary widely. So, what I might share for those on this elusive hunt, are 2 things: 1 is figuring airflow by using a similar probe but with additional tubing connection (Pitot tube). It works the same but collects 2 measurements simultaneously static and velocity. To get an accurate test a series of holes (travers) are drilled across a section of ductwork at predetermined spacing and a timed and averaging is done and then a bunch of tedious conversion mathematics which seems like a lot of trouble. The alternative using this instrument is a single hole in center and an averaging multiplier of .9 is used to get within +/-5%. Another method listed below blew me away and I'd like to hear comments on this. It utilizes a simple formula using volts, amps draw and temperature rise to determine airflow. I've included a link to the article library.coburns.com/HVACTechTips/Calculating%20CFM%20Coburns.pdf
@HomePerformance7 жыл бұрын
+Tie Dye thanks for sharing! Here are a bunch of other airflow test techniques: kzbin.info/www/bejne/ambKiWqAl5tjgK8
@JCO847 Жыл бұрын
Thank you for this helpful video. I am a homeowner looking to learn. On those pressure probes, it looks like they just face into the airflow and it doesnt matter if the hole is "sealed" by the base of the probe where it enters the ducts or am i wrong on that?
@scottmilne35222 жыл бұрын
Thanks for your clear, concise explanations! I am a residential remodeling contractor. I am having trouble explaining some of these concepts to a client, who thinks that simply closing off vents to half the house in the winter will save energy, that the furnace burns less fuel/gas when vents are closed, and that static pressure can/will damage the furnace components. They have a single stage unit, no AC. Do you have a video that might explain these concepts? My analogy of "getting 10 pounds of sugar in a 5 pound bag" is not getting the point across 🙂 Thank you!
@HomePerformance2 жыл бұрын
You might try this one first, Scott- it’s shorter and simpler: Static Pressure Testing for Home HVAC: What, Why, and How in 2 Minutes kzbin.info/www/bejne/gaSYZneZiJaNnbM
@rickeydesi82378 жыл бұрын
great video lets see more on static pressure
@kevinsaint20 Жыл бұрын
With all of these tests, would you have pressed the “diff” button on the manometer to see the pressure drop from any one location to another?
@mackenziegray20902 жыл бұрын
I came across, like carrier where I can put static probes in the service light whole and through the limit switch. It seems to work fine without drilling wholes.
@HomePerformance2 жыл бұрын
As stated in many other comments, you’ll get a higher than actual reading since your probe is not outside the equipment at the limit switch, but if it passes your way, great!
@kiltedpiper98 Жыл бұрын
Is the best way to measure pressure across the filter if you have wall grill filters, to measure the room pressure and make that the delta? Or is it better to remove the filter?
@TacoLibreF-CKYT Жыл бұрын
Great video. I've done some drilling into plenums and ducts before for testing but never into a unit and below the coils. Any rule of thumb as to where the coils sit in most units so hitting them when drilling into the units can be avoided?
@kevinbennett25655 жыл бұрын
Usually I'll pull the limit if the hole is too big I'll put metal tape to make up the space for the magnetic static probe and of course for accuracy . Not all but alot of times in California at least drilling on the side is a real task sometimes the limit is the only answer . Great video
@HomePerformance5 жыл бұрын
Agreed, if the limit access is the only way, do it!
@JohnDoe-jt9oq5 жыл бұрын
I'm curious. Why do you have a $1500 manometer, but only a Ryobi drill? (Kidding.) Thanks for the video, I'm new to the field, just finished A/C season and I'm heading into furnace season.
@HomePerformance5 жыл бұрын
Haha, and I still have a few shirts from 15 years ago too. Welcome to the whole house practice, hope you get your hands on a blower door and start showing up the competition!
@CarlosHernandez-ih5eqАй бұрын
is there another door behind outter door that covers all low voltage and circuit board? if so that probe shouldn’t go inside the door inside?
@SawHorseDesignBuild2 жыл бұрын
Great video. Most installers might be aware of the pressure drop from the filter- if that. They don't know about the other factors such as ductwork.
@HomePerformance2 жыл бұрын
Thanks as always, Matt
@pernelllewis55416 жыл бұрын
Absolutely the best explanation I've seen on KZbin!!!
@HomePerformance6 жыл бұрын
Thanks Parnell! Glad you found us!
@Rob-pg7rb5 жыл бұрын
I am working on a tenant complaint about AC cooling not being good enough. This is for a an upstairs duplex apartment unit. The evap is getting nice and cold-maybe too cold. I think the fan speed for the cool is too low. Right now the cool for the motor is on the BLUE (Med-Low). And the heat is on YELOW (Med-High). I alway heard that the cool speed should generally be faster than the heat speed, so Im going to switch the two so the cool is Med-High and the heat is Med-Low. Will this help solve my cooling issue?
@HomePerformance5 жыл бұрын
Good q, but you have only one data point. I’d want to know temp and RH in the apt, actual airflow thru the indoor coil, whether the unit is sized properly, air leakage of the apt walls, ceiling and floor. You could mess around there for years, or solve the problem in one visit if you test. Check out my interview on the HVAC School Podcast: www.hvacrschool.com/blower-door-testing-building-performance-w-corbett-lunsford-podcast/
@rw4928 ай бұрын
Question, when measuring the pressure across the coil you subtracted .07-.21=.14. When measuring across the furnace .38 + .21= .59 for the furnace you added your two different pressures but across the coil you subtracted. Not sure why you subtracted one and added the other.
@ekie857 ай бұрын
Some closet are tight and can not make hole on the side of the furnace, can I stick the probe in the high limit switch hole?
@Sightthrough8 жыл бұрын
Hey, just a heads up from someone who checks static pressure often on gas furnaces, there is a hole into the heat exchanger available after the blower that the manufacturers make for us, just remove the primary limit switch, I prefer NOT to drill holes into equipment if it is unnecessary.
@HomePerformance8 жыл бұрын
+Sightthrough, if you test at the high limit switch hole you will get a higher than actual TESP reading, since you're also picking up the top of the heat exchanger.
@joeydelmarsjr.6463 жыл бұрын
i got a 4ton for 1300sqft thats 350ft per ton in southern Nevada easy 115 degree days, i aim to get 1600cfm and my filter is 20x20x1 side by side for a total of 20x40 filter return. i currently use the honeywell HD merv 11 filters but i think ill start using the 3m 1200 merv 11 because of the more surface area on the filter to help decrease static pressure if that doesnt help ill try to use 4in filter
@Legion_275 жыл бұрын
good question everyone, so if you have a roof top packaged unit and want to calculate its external static pressure, do you consider internal pressure drops due to filters and coil? Or do you only calculate the pressure drop due to duct system?
@michaelsimi40778 жыл бұрын
Great breakdown of Total static pressure. Thanks for the video!!
@HomePerformance8 жыл бұрын
Rock on, +Michael Simi !
@kingsrook56 жыл бұрын
I’d like to see how to use this static pressure test along with a flow hood to measure duct leakage.
@HomePerformance6 жыл бұрын
Good idea Brian- those are two pretty different tests, but there are some interesting ways to link them. I’ll see what we can do.
@brendanreid5936 жыл бұрын
Brian - estimating total airflow based on static pressure and then comparing it to measured flow with a hood sometimes works. However, there's a lot of inherent inaccuracy which greatly reduces the confidence, and the tighter the ducts the greater the duct leakage inaccuracy. The problem is that whenever you subtract one BIG number from another BIG number, minor % errors in either value get magnified in the final result (estimate). Essentially inferring leakage is not the same as measuring it. A duct airtightness test (duct blaster or aeroseal) is the only way to accurately measure duct leakage. Its referenced in all the codes and is how SMACNA standards do it in commercial ducts.
@aryanritchie77594 жыл бұрын
There’s a device called a duct blaster that does that
@albertescober2728Ай бұрын
Does the unit needs to be ON fan only, heat or cool to get the measurements?
@manuwelaboy50276 жыл бұрын
Thank you for this most informative video. I am NOT hvac saavy,but my understanding of it's basic principles,has now been thoroughly upgraded from OH?,to I understand what your saying. Life is good! Be well,friend.
@HomePerformance6 жыл бұрын
Awesome to hear, buddy! Thanks for your feedback!
@lvvry18554 жыл бұрын
Wow!What a great teacher you are. Thanks.
@HomePerformance4 жыл бұрын
Hey, what a nice thing to say! Thanks!
@RonNL10303 жыл бұрын
Couldn’t have explained it any better. Thank you!
@HomePerformance3 жыл бұрын
Hey, thanks Ronald!
@joshoooway3 жыл бұрын
Never thought I'd learn as much from Jeff Goldblum as I've learned today
@HomePerformance3 жыл бұрын
Life finds a way
@jebusfreek66675 жыл бұрын
Hope you can point me in the right direction. Just checked my furnace, heat only no AC, and I am getting .07 on supply side, and .48 on return side. Total is a little above .5, but the fact that I only have .07 on the supply side seems very wrong to me. Where should I start looking for issues?
@HomePerformance5 жыл бұрын
Replace the filter first. Heating mode is often low speed on an air handler, so don’t be too concerned with the supply reading for now. You’d also want to take temps in rooms and airflow out of vents and thru system to get the big picture.
@jebusfreek66675 жыл бұрын
@@HomePerformance Thanks for the quick reply. I replaced the filter before even checking. I am pretty sure a ton of junk fell into the floor returns when the previous owner opened the walls up and the blown insulation fell out everywhere. I'm guessing that is why the return side is so high. Is there a way to force the air handler to blow in a higher mode to make sure I am able to get higher supply pressures?
@sp1200M3D2 жыл бұрын
I’m conflicted if I can move up to a MERV 13 furnace filter. I believe I have a 2 ton gas/AC furnace. Any suggestions would be great. Hell, I’d also like for someone to test my system’s static pressure. Any certifications I should look for in company? Cheers, great video.
@HomePerformance2 жыл бұрын
Sorry Pete, no certifications for this one, but you can search google for it and maybe find somebody who’s trying to be better than the rest. If you go with a 4” pleated filter then absolutely you can.
@sp1200M3D2 жыл бұрын
@@HomePerformance I actually have a 20x25x5 inch pleated MERV 10 furnace filter right now, but I’d like to move up. I think I should be ok. I’ll tell you something crazy though, I just found significant water vapor damage inside of my wall from the microwave “range hood” over the stove, which some how is blowing inside of the wall. I can hear the wind in the wall from the other side when it’s running. I look at the best mold inspectors in the nation’s reports for a living and I have not seen this source area to date yet. Talk about negative pressure lol Thanks for the reply btw.
@HomePerformance2 жыл бұрын
Yikes! Sounds like they forgot to cut a hole in the sheathing- half a job done is much worse than none at all in that case.
@sp1200M3D2 жыл бұрын
@@HomePerformance I thought there was an exhaust line out the top of my roof. None. Just blows right in the wall…
@JV-si4kp4 жыл бұрын
Hi, I'm a homeowner that just had a new packaged unit installed and replaced the duct work as well. I noticed the return vents whistling and pulling more air. I contacted the installer and they wanted to change the type of filter or return grill. I'm concerned that the duct work may be improperly designed. I'm going to ask them to perform the test but I want to understand if changing the blower speed setting is important because they recommended changing it.
@coldfinger459sub08 жыл бұрын
Thank you, bravo , excellent job at explain in layman's terms so our consumers can get a better understanding of what should be done on every installation. It's too bad the majority of technicians installing furnaces do not even know this, at most they just seen pictures in literature but never had their bosses actually run them through it and explain it to them so it never gets done and the customer usually ends up with an inferior install. Thank you for all your effort and passion to educate people about the subject.
@HomePerformance8 жыл бұрын
Thanks so much for your message, +t lech, I'm happy to be helping the world move forward. Back atcha!
@goodkao5 жыл бұрын
I really like the way you teach and explain so clear for us to understand. Thanks!
@HomePerformance5 жыл бұрын
Glad to have helped you!
@edwardzachary14265 жыл бұрын
You said if you dont see a hole on the side of the furnace your contractors are bad. What about removing the high temperature limit? Everyone I know uses that when they can to avoid drilling holes.
@HomePerformance5 жыл бұрын
Yes, that can work, but it’s guaranteed to give you a higher than actual reading of TESP. And based on my testing history with hundreds of systems, I feel confident most contractors are never testing this. If they ARE, they should be showing that they pass on the unit, alongside all the other stickers on there.
@thezambonypony28174 жыл бұрын
Thanks for this video! Very informative, especially after my boss asked me what external static pressure is 😁
@HomePerformance4 жыл бұрын
PERFECT FORM, ZAMBONY
@Anavllama2 жыл бұрын
My heat pumps Fujitsu 2 ton (ARU24RGLX) , came with a default setting of Standard static pressure: 0.18 in.WG (45 Pa). I asked the installer to show me the equations they used to match up with the proper setting for static pressure. Of course I didn't receive any such information but did get the line: The system was designed for that heat pump so its all good. In the design/tech manual the function code for static pressure is 26 and the default setting is 31 which equates to .18 in. The settings start at 03 = .12 in (30 Pa), in increments of one up to a setting of 20 = 0.8 in (200 Pa). Then one has 31 = .18in and 32 = automatic air flow adjustment. I find it hard to believe that any work was done to optimize static pressure setting but want to know if leaving it at the default is best practice for installations? Would it be feasible to set it to 32 Auto adjusting??
@HomePerformance2 жыл бұрын
Whoa, .18 is insanely low. Yes, I’d advise the auto-adjusting I guess, though not sure why it’s not defaulted there.
@Anavllama2 жыл бұрын
@@HomePerformance Well I looked in the D&T Manual and it appears the setting 32 Automatic Air FLow is specifically for a procedure as follows and thus not to be used full time. I may simply use a middle setting for now (and try the procedure below in the summer) like mode 11 approx .44 inWG (in the middle between .12 and .8 ) Quote: Automatic airflow adjustment procedures 1. To start the auto setting, use setting value 32 in function number 26. 2. Run the air conditioner on fan mode (High). * For instructions on how to operate the air conditioner, refer to the operation manual of the remote controller. During automatic airflow adjustment, the mode will be fixed at fan (High). When this function is active, do not operate the outdoor unit. 3. The air conditioner will run for about 1 to 8 min then stop automatically. * Do not change the throttles of the inlet and outlet ports during operation. When used in a group control system, the setting will take about 10 min. 4. Turn the air conditioner off and on again. 5. Check the setting value of function number 26. * If the setting value has not changed, repeat the procedure from step 2. CAUTION When the duct or outlet installations are changed after the Automatic airflow adjustment is completed, repeat the procedure from step 1. unquote:
@HomePerformance2 жыл бұрын
Sounds weird, I’m out of my depth on that one
@teacherlynn6715 жыл бұрын
Sorry, I do have one more question if you are nice enough. Out here we have our airhandlers (furnace and A coil and ductwork) in our attics. There is a movement when they are replaced to move the unit to the garage so maintenance is easier. How would you suggest setting up ductwork to have the proper pressures? The original ductwork would remain in the attic but the unit would be about 9 foot lower and 6 foot away from where it was? Also, most attic ductwork is flexible but metal would be run to the garage. Probably too much but at least I tried….and thank you.
@hvacando56092 жыл бұрын
Hi Corbett just makin sure now, the friction rate is on each manual of the air handler depending on the speed of the blower? And we have to match that friction rate based on how we calculate sp, pressure drop, equivalent length, etc after the design is complete correct?
@HomePerformance2 жыл бұрын
Whoa Ando, you’re losing me- but I will have some HVAC design courses coming online soon.
@johnc21167 жыл бұрын
What a great video, thank you so much. The furnaces in both of my houses had no ports for measuring?? but they do now.
@HomePerformance7 жыл бұрын
+john clark you are officially one of the illuminati. Welcome.
@brs43895 жыл бұрын
Have you ever watched How It's Made? It would take a lot to add that whole to the manufacturing process.
@HomePerformance5 жыл бұрын
Exactly!
@zreap58985 ай бұрын
I'm having a hard time getting the right static pressure. I'm measuring before coil and after filter and I get a 1wc so I lower the speed of the blower to get my .5wc and now the air flow just seems too low I feel like I'm going to freeze the coil being too low or set off a high limit switch when heating the home. I'm just confused and need guidance.
@HomePerformance5 ай бұрын
The ducts are too small. Add more ductwork right as it comes out of the unit.
@zreap58985 ай бұрын
@HomePerformance Thank you sir I'll see what I can do. I was told 2 different things from past employers one said that I could run the blower at lower cfm just as long as I'm staying within the 70% range of the CFM and another said I'm able to run the system with a higher static as long as I don't go past 1"wc.
@HomePerformance5 ай бұрын
That’s life :)
@groverd66688 жыл бұрын
I am planning to use the pressure drop across my air filter to determine when the correct time to change it is. I have a set of pitot tube and required hardware to install them. I plan to but 1 on each side of the filter. That said, this mean one pitot tube will be located in the blower assembly of my HVAC system. Based on where I have seen in your video and others, the static pressure should be somewhat constant. Since this is a home unit, I do not expect a large variation in pressure across the duct and plan to use only 2 pitot tubes. With one on each side side of the air filter, located in the center (side-to-side) of the duct and about 6" into the air flow. Other than ensuring I am on the correct side of the blower fan, is the location of the pitot tube in the blower compartment important for measuring the static pressure?
@HomePerformance8 жыл бұрын
+Grover D first, I assume you mean just static pressure probe when you say 'pitot tube'- a pitot tube also measures total pressure, which you won't need. I'd sample a few places in the cabinet and all different directions for pointing the probe, but yes, it shouldn't matter much.
@clintwall630115 күн бұрын
Any manufacturers ever get a round to providing a hole for testing?
@victorsr67082 жыл бұрын
Interesting never drilled a hole in a furnace to get SP I usually remove the hi -temp sensor out of the furnace and use that hole, I find it easier to do than to drill a hole. Can I put my sticker on the furnace??
@HomePerformance2 жыл бұрын
Limit switch hole will give you a higher than actual reading- if it passes there, you’re good, but I find most installs need every 0.01” they can get. Yes, put your sticker on- AND write the SP data on it!
@justaguy15765 жыл бұрын
So if you take the static pressure before the A-Coil and after the A-Coil, could you use that data do determine if and to what extent the A-Coil needs cleaning? I am always leery about what harsh chemicals do to the a coil, and if perhaps just a light vacuuming or even leaving it alone would be better than spraying it with chemicals every season for longer life.
@HomePerformance5 жыл бұрын
Yes, but it’s better in most cases to just look at it
@joeydelmarsjr.6465 жыл бұрын
how much should i pay to get this test done, since i dont know how well the 25 year old ac unit is performing. reason is i will be getting a brand new unit and i want to see before and after performance results.
@HomePerformance5 жыл бұрын
Just make sure it’s in the contract for your install, and they can test the old one before taking it apart. It takes only 10 minutes, as you see. Maybe $100 if they know what they’re doing, maybe $10,000 if you’re scaring them.
@marcusaurelis9 ай бұрын
Can’t you put the probe into the high limit cut out to the the after blower motor reading?
@HomePerformance9 ай бұрын
It will give you a higher reading
@jdvigil55644 жыл бұрын
When static is higher is blower amps lower or higher, because technically we are moving less air?
@HomePerformance4 жыл бұрын
Higher- the fan is having to fight back
@jdvigil55644 жыл бұрын
@@HomePerformance Have you tested and verified that? That's what I was looking for on you tube, just haven't found that video yet. It started as a topic of discussion that if a motor is not moving as much air it's not working as hard as when is loaded. Thanks
@jdvigil55644 жыл бұрын
This Video Demonstration kinda supports my theory. kzbin.info/www/bejne/fmHIfZp7r7CrmpY Your thoughts. By blocking off the air flow, static goes up, amps go down.......... Thanks,
@mynamesjeff-k2u Жыл бұрын
Excellent video!! is ti more important to have a higher static pressure on the supply or the return?
@shankil29758 жыл бұрын
Does this video assume the filter to be in the furnace enclosure? What if the filter is behind the return grille i.e 10 to ft away from the furnace
@HomePerformance8 жыл бұрын
+sankar lakshmipathi in that case, measure the TESP in the same place, but your return ductwork pressure drop will be higher. As long as it was designed that way in Manual D/ASHRAE you're good.
@JerryLynch25 жыл бұрын
Hello Corbett, First off, way to nail it, great presentation, period! Please bear with me on my question... I hope it does not appear ignorant. How would I check down flow ( mobile home furnace ) filters are attached to backside of door and in this particular case, this unit is about 22 yrs old and does not have central air. There is an exterior independent a/c unit. The back of the Furnace obviously is in the cabinet ( closet ) all ignition, flame sensor, are internal and completely enclosed. Blower is in your face and completely exposed. Thanks, Jerry
@HomePerformance5 жыл бұрын
Wow, Jerry, good question, but I don't have an answer for you. No experience with this type of unit. Check out this vid to find a way that might work: kzbin.info/www/bejne/b6fanoNniZeFm6s
@JerryLynch25 жыл бұрын
Hello Corbett! Thank you for taking time out to respond and thank you even more for taking additional time with further assistance. Have a great day!
@HomePerformance5 жыл бұрын
Anytime, Jerry- thanks for following!
@JerryLynch25 жыл бұрын
@@HomePerformance You bet!
@teacherlynn6714 жыл бұрын
Don’t you have a book for sale? Also, my unit is in my attic with a 4 ton coil but I want to install my new unit in my garage 9 foot below. 18” Return with a 14” and a 12” Supply coming off the plenum. Any thoughts?
@HomePerformance4 жыл бұрын
Yes, my book is at: buildingperformanceworkshop.com/homeperformancediagnosticsbook And your ductwork can easily be redesigned if needed, to put the equip in the garage.
@jagmini27 жыл бұрын
Fantastic job. I now know what to look for to resolve my problem.
@HomePerformance7 жыл бұрын
So glad to have helped!
@kylerae15757 жыл бұрын
I've been in the industry for a year, I was told that yes you shouldn't have more TESP than what the manufacture says but was told by my seniors that you're allowed a little wiggle room (.1-.15 more than the static pressure) because of the filter. Some customers prefer certain types of air filters that will increase the static pressure. Are my seniors right and what do you do to compensate for the thicker filters?
@HomePerformance7 жыл бұрын
+Kyle Rae great question! Just think about the fact that it’s a pass/fail test. If you’re over .5 even a little, you risk another pro telling your client you don’t know what you’re doing. The old school guys are used to nobody checking their work, but once your client thinks you lied to them one time, they will never hire you again. Remind them that TESP includes the filter- the filter doesn’t get added later as fudge factor. If a homeowner wants a higher MERV filter, they have to go wider media or upsize the return. Keep up the great work challenging the old rules of thumb!!!
@umeng2002 Жыл бұрын
Your fan motor doesn't care about anything other than the TESP, filter or not.
@ChopperCharles3 жыл бұрын
What if the filters are at the return grilles in the walls, and not right in front of the hvac unit?
@HomePerformance3 жыл бұрын
Same locations for testing, they just mean different things.
@ChopperCharles3 жыл бұрын
@@HomePerformance Would love to see a video about that, and what different things they mean.
@danielcallahan43852 жыл бұрын
Can you help me understand how you are only measuring static pressure if you your probe is facing into the flow? Wouldn’t that be total pressure, ie velocity pressure + static pressure?
@HomePerformance2 жыл бұрын
The head is aerodynamically shaped, so you can be sure any turbulence is removed from the measurement theoretically if you point it into the flow.