Surge Protection Device Installation in Main Distribution Board | SPD |

  Рет қаралды 135,985

Electrical Technician

Electrical Technician

Күн бұрын

Пікірлер
@rizwantayyab3947
@rizwantayyab3947 2 жыл бұрын
Bohat shukria first time ya cheez dakhi aor ap ka samjana ka tariqa bohat acha ha
@rizwantayyab3947
@rizwantayyab3947 2 жыл бұрын
Sir I am Pakistani but I am industrial electrician from oman
@qaritariq3065
@qaritariq3065 2 жыл бұрын
ماشاءاللہ بھائی جان آپ کی ویڈیو بہت ہی کمال کی ہوتی ہیں
@usmanzaheer4691
@usmanzaheer4691 Жыл бұрын
Very helpful and Informative Video. Thanks from PAK
@subhajitdey8147
@subhajitdey8147 Жыл бұрын
Very interesting and informative video. Thank you Sir 🎉
@StyleCrazy02
@StyleCrazy02 4 ай бұрын
Great explanation sir Thank you sir for helping us
@maqueboolalam4157
@maqueboolalam4157 4 ай бұрын
Very nice learning vedio sir
@gaganbaro6925
@gaganbaro6925 2 жыл бұрын
Apki har videos me aek cis atcha lagti he..wo he explanation
@ElectricalTechnician
@ElectricalTechnician 2 жыл бұрын
Thank You Dear Gagan
@mihirmajumdar7023
@mihirmajumdar7023 Жыл бұрын
Very useful and nicely explained.Thanks
@waseemfarooqi5777
@waseemfarooqi5777 2 жыл бұрын
Bohat achey se ap nay guide kiya aur SPD ky connection kernay ka tareeka bataya.... aik question hai..... jo earth power supply Company deyte hai hum kiya Company nay jo apna earth deya hai es earth ko SPD se connect ker saktey hain
@ummetahirataqua568
@ummetahirataqua568 2 жыл бұрын
Thanks for Very nice From bangladesh Saleh
@SanjaySingh-dj7tx
@SanjaySingh-dj7tx 7 ай бұрын
Bahut acche se samjhane ke liye thank u Sar
@CNCElectric1988
@CNCElectric1988 2 жыл бұрын
Nice video👍
@ElectricalTechnician
@ElectricalTechnician 2 жыл бұрын
Thanks 👍
@localtraveller8647
@localtraveller8647 Жыл бұрын
Good information to freshers❤
@TheVJHoney
@TheVJHoney 2 жыл бұрын
Very well explained. Thanku for the video.. From Pakistan 🇵🇰
@ransagark.c3039
@ransagark.c3039 2 жыл бұрын
Thank you sir bahut achhxa video
@SubhashPorte
@SubhashPorte Жыл бұрын
Very important information
@christopherpetrov2355
@christopherpetrov2355 2 жыл бұрын
Perfect!! 💗💗
@khalidameen1704
@khalidameen1704 2 жыл бұрын
important lecture very nice
@SHAMIMAKHTAR224
@SHAMIMAKHTAR224 2 жыл бұрын
Very very good explanation
@gsrajanganga7206
@gsrajanganga7206 2 жыл бұрын
Good explain 👍👍
@publicinformationsialkot
@publicinformationsialkot Жыл бұрын
Very nice
@rajibpasha1517
@rajibpasha1517 2 жыл бұрын
Very good video, thank you, sir
@deeapkprajapati3323
@deeapkprajapati3323 2 жыл бұрын
Very good explane sir ji
@mukeshnayak-gn6dr
@mukeshnayak-gn6dr Жыл бұрын
Good 👍 work
@shaileshsonwane8612
@shaileshsonwane8612 2 жыл бұрын
MCB me input supply niche se rahta aur out put uppar se rahta hai baki mast hai thik hai...
@sourabhpanse
@sourabhpanse 2 жыл бұрын
Not necessarily. Kisi mcb mei input output aisa kuchh nahi hota.
@frinojtr4364
@frinojtr4364 Жыл бұрын
Well done Bro. Have no doubt on the connection now. One question, As our regular power supply voltage is 230-240, This model will only Earth out voltage above 385 V ?? will it be safe for electronic devices ?
@techchat370
@techchat370 11 ай бұрын
SAME QUESTION IT SHOULD BE 275V SPD INSTEAD OF 385V SPD
@shawelectric808
@shawelectric808 2 жыл бұрын
very good sir ji
@deepakk1347
@deepakk1347 Күн бұрын
Sir kya hamesa SPD connection me SPD ko DPMCB ke baad lagega ? ya stablizer ke baad mi lagana hai?
@rashidrahi1490
@rashidrahi1490 Жыл бұрын
Thank you sir
@shrabonel2338
@shrabonel2338 2 жыл бұрын
thank you❤🙏 sir ji
@dharmvirdharmvir2464
@dharmvirdharmvir2464 2 жыл бұрын
Thank you so much
@naumanazeem3445
@naumanazeem3445 11 ай бұрын
Informed
@NazirKhan-jf2eq
@NazirKhan-jf2eq 2 жыл бұрын
Good sar
@dhanjitchoudhury99
@dhanjitchoudhury99 8 ай бұрын
Pls make a video of details connection of ELR, Phase reversal rely(VMR3) and MCCB Connection.
@AkashSinku-sg4zv
@AkashSinku-sg4zv 3 ай бұрын
Sir, SPD Earthing or Ghar ka Earthing alag alag dena hoga ??
@SamorEarthingBoringserviceLaho
@SamorEarthingBoringserviceLaho 6 ай бұрын
Nice
@mubasharnazar4684
@mubasharnazar4684 2 жыл бұрын
Good
@vardansaxena567
@vardansaxena567 2 жыл бұрын
Thanx
@randhawatheengineer.2484
@randhawatheengineer.2484 Жыл бұрын
sir this is khuram here from pakistan. kindly tell me if we do not having earthing in my home how i use spd in my home....secondly if we connect earthing point to any floor area is it working.........?
@anwarhussain8557
@anwarhussain8557 2 жыл бұрын
सर जी अगर SPD के अर्थिंग को घर के अर्थिंग के साथ कनेक्ट करेंगे तो 11000 वोल्ट घर के अर्थिंग में चला जायेगा जे की फिर से वापस घर में आ जायेगा। इससे बचने के लिए क्या हमे दो अर्थिंग करना पड़ेगा एक SPD के लिए और एक घर के लिए।
@astamanrai5240
@astamanrai5240 2 жыл бұрын
Sir ji Jo ap bata rahe the ki yad huwa ,to matlob Ghar ka earthing our ,SPD kevliye Alasa protect earthing Karna padega yahi bad .
@akamulyaherbsharyana9076
@akamulyaherbsharyana9076 3 ай бұрын
Sir I have 2 meter one single phase and one 3 phase on my ground and first floor. Earthing 1 hi extra hai. Kya ek earthing me dono meter ke spd ,single phase ki or 3 phase ki join kar sakte hain kya
@SachinJadhav-wo6yg
@SachinJadhav-wo6yg Жыл бұрын
Ismain Change over Circuit Use Kar Sakte hain kya sir ?
@RajaNadeem-nt3uw
@RajaNadeem-nt3uw 9 ай бұрын
👍
@917439
@917439 Жыл бұрын
I think spd earth should be separate and not connected to the same mcb earth, else you can get earth shock burns inside house
@msalman373
@msalman373 2 жыл бұрын
Good explanation, tell me one thing plz, my earthing is only 24 feet deep. So if i connect that earthing with spd then i can get same benefits or i have to make my earthing more deeper ?
@rahulvarghese497
@rahulvarghese497 2 жыл бұрын
Earth connection resistance should be below 5 ohms.
@msalman373
@msalman373 2 жыл бұрын
@@rahulvarghese497 how can we check this value ? If i have only amp or volt meter
@ninbojja219
@ninbojja219 2 жыл бұрын
Abe 24 feet😰 mera ghar mei 5 feet earthing hei. And wo achcha kaam kar raha hei. Mera ghar ko 10 saal hua. Ab tak koi problem nahi aaya. Even ghar near forest area mei hei aur udhar bijli ki current main line mei pakadta hei. Hardly i lost chip board of TV, Washing machine and chimney. And I only installed 4 DP-MCB for 2 G&F floor Inverter current and another 2 for AEH current. Main meter->fuge->4DP-Mcb i didn't even installed DP MCB, RCCB,SPD for whole house.
@akshayveralkar4611
@akshayveralkar4611 Жыл бұрын
The home with computer, tv, water heater, fridge, washing machine, ac do we need spd?
@deepakk1347
@deepakk1347 Күн бұрын
how to install an spd in a consumer unit with rccb, mcb and voltage protector
@abhinandanmohanty846
@abhinandanmohanty846 Жыл бұрын
Do we need separate earthing for SPD or in the same home earthing, please let me know
@frinojtr4364
@frinojtr4364 Жыл бұрын
Dedicated Earthing is mandatory, Otherwise there is risk of electric shock through the earth terminals of Three pin socket and related equipment
@abhinandanmohanty846
@abhinandanmohanty846 Жыл бұрын
@@frinojtr4364 Thanks
@idealPlumbringworks
@idealPlumbringworks Жыл бұрын
Sir spd ghr k laya kitna kv ka hona chaiye please reply me
@pawanmobiledardahi796
@pawanmobiledardahi796 3 ай бұрын
Sir agar mai spd me earth connect nahi karunga to kya o work karega yes or no
@rajeshseeram7543
@rajeshseeram7543 2 ай бұрын
No
@rajvirsingh4558
@rajvirsingh4558 2 жыл бұрын
Good Upload but can we use spd in first place...so the circuit will remain safe... please clarify 🙏
@ElectricalTechnician
@ElectricalTechnician 2 жыл бұрын
Yes you can
@sourabhpanse
@sourabhpanse 2 жыл бұрын
Doesn't matter. Both are in parallel
@abhinandanmohanty846
@abhinandanmohanty846 Жыл бұрын
​@@sourabhpanse Do we need separate earthing for SPD or in the same home earthing, please let me know
@sourabhpanse
@sourabhpanse Жыл бұрын
@@abhinandanmohanty846 separate and stronger earthing as its for high voltage surge
@frinojtr4364
@frinojtr4364 Жыл бұрын
SPD connect after two pole MCB is to protect your SPD from instant burning, SPD cost a lot more than MCB. By doing this you get protection for the Home and also for your SPD device
@vishalraj-ho5hb
@vishalraj-ho5hb Жыл бұрын
Bro so neutral connection will be taken from bus bar to switch board
@sourabhsoni3603
@sourabhsoni3603 Жыл бұрын
Mere ghar me 3 phase hain aur usme 4 Pole ka SPD lagaya and its price is about Rs 12000
@beautifulworld1819
@beautifulworld1819 2 жыл бұрын
Sir tense ka digital under and over voltage best rahe ga
@ElectricalTechnician
@ElectricalTechnician 2 жыл бұрын
usmai Over Voltage and Under voltage par minimum 5 sec wait karega tripping ke liye aesa device buy karo jisko hum aapne requirment ke according Delay Time Set kar sake
@beautifulworld1819
@beautifulworld1819 2 жыл бұрын
@@ElectricalTechnician us main .1sec tak minimum delay hota hai
@rahulvarghese497
@rahulvarghese497 2 жыл бұрын
But it won’t save from surges
@gavindsouza01
@gavindsouza01 2 жыл бұрын
SPD kilye sprate earthings chaiye kya ?
@ElectricalTechnician
@ElectricalTechnician 2 жыл бұрын
ji ha
@gavindsouza01
@gavindsouza01 2 жыл бұрын
@@ElectricalTechnician mere Ghar par alredy earthings he usko joint nai karsakte kya?
@idealPlumbringworks
@idealPlumbringworks Жыл бұрын
Sir cnc spd kah sa buy kara
@nnsn7201
@nnsn7201 2 жыл бұрын
SPD should be installed first afterwards the two pole MCB then RCCB and single pole MCB's because as per the above installation the MCB will drip down or get burnt first in case of surge and hence SPD will not do its task.
@sourabhpanse
@sourabhpanse 2 жыл бұрын
Dp mcb and spd are in parallel so whichever is first doesn't matter
@sourabhpanse
@sourabhpanse 2 жыл бұрын
Both will receive high voltage and current at same time
@adityasurve7397
@adityasurve7397 2 жыл бұрын
kya hum SPD ko sabse start me laga sakte hai?
@sourabhpanse
@sourabhpanse 2 жыл бұрын
Yes but doesn't matter
@mohdaslam5033
@mohdaslam5033 2 жыл бұрын
SPD is connected in parallel, so that the surge can also flow to the remaining circuit? Or the SPD bypasses it into the earth? What is actually happening here.
@ninbojja219
@ninbojja219 2 жыл бұрын
Yes. It bypass it to the earth. only lightning current (which is 20KA-40KA) flows through main current wire whether it is a neutral or phase it will earthing. the surge can only pass through meter, DP-mcb, and SPD. Next circuit remains safe. If more then 40KA current passes through main Line then fuse will blown or transformer may blast at the main line transformer. So home wiring will be safe..
@Khan-ug5wp
@Khan-ug5wp 6 ай бұрын
Me ni agar socket lagana he to ground longa ya3 nahee
@baljindersinghkhalsa3807
@baljindersinghkhalsa3807 8 ай бұрын
Hello cnc product ko kase order kare
@UNAS2000
@UNAS2000 Жыл бұрын
Tell me the name of best SPD DEVICE available in India. Also inform us it's Amp etc for home use.
@Firegaming8833
@Firegaming8833 2 жыл бұрын
Life is short " "Girlfriend is nothing" "Mother father God bless you" "Support is everything" 🔥❣.
@ransagark.c3039
@ransagark.c3039 2 жыл бұрын
Forward/Reverse star Delta without timmer control diagram and connection diagram banao sikhao plzz sir
@rohitkhanna9695
@rohitkhanna9695 2 жыл бұрын
Is vmr and SPD is same function
@jdelectricalswork6841
@jdelectricalswork6841 2 жыл бұрын
SPD ki earthing rod ki lenth kya honi chahiye minimum???
@Khan_altaf2020
@Khan_altaf2020 Ай бұрын
We’re by CNC products
@abhikdutta1842
@abhikdutta1842 Жыл бұрын
There are many types of spd how to know which one to choose
@RajeshKumar-my5ml
@RajeshKumar-my5ml 2 жыл бұрын
Sir cnc ka product kaise kharide sir
@ElectricalTechnician
@ElectricalTechnician 2 жыл бұрын
You Can Buy and check the price of CNC Company Product by this website cnc-official.com/discount/electrical
@muhammadhumayoun8815
@muhammadhumayoun8815 Жыл бұрын
If we use RCBO Instead of spd then what happend ....it also give us protection against surg
@ElectricalTechnician
@ElectricalTechnician Жыл бұрын
RCBO Provide protection only for earth fault
@muhammadhumayoun8815
@muhammadhumayoun8815 Жыл бұрын
@@ElectricalTechnician دھنے وات
@muhammadazamkhanwazir4777
@muhammadazamkhanwazir4777 6 ай бұрын
Jb MCB ke out SPD may ja rhe hain or nikal bhe usi jaga say rhe hy to phr kha ke voltage protection hoge janab 😂😂😂
@mudabbirzaidi148
@mudabbirzaidi148 6 ай бұрын
Earthing se
@faysalhossain1612
@faysalhossain1612 Жыл бұрын
UC 385, isn't that too much?
@PradeepkumarSahu-h5o
@PradeepkumarSahu-h5o 5 ай бұрын
Yah prodect mujhey lena thaa kaha. Mileyga ,uska koi contect no bhejy
@neeladrishekharmondal3087
@neeladrishekharmondal3087 Жыл бұрын
RCBO vs SPD?
@babujiana
@babujiana 2 жыл бұрын
why u use 2 MCB in last
@sourabhpanse
@sourabhpanse 2 жыл бұрын
Branching
@randhawatheengineer.2484
@randhawatheengineer.2484 Жыл бұрын
please must answer my question
@baharuddinkxj3621
@baharuddinkxj3621 2 жыл бұрын
मुझे सीएनसी ब्रेन का कुछ मटेरियल चाहिए आप मुझे दे सकता है
@harpindersingh3138
@harpindersingh3138 Жыл бұрын
कहीं लिंक तो दिया नहीं खरीदे कहां से
@ramawatpremdas091
@ramawatpremdas091 6 ай бұрын
Ager earth kharab he to sab damege ho jayega😢😢 ye koi solyution nhi he
@jaxongiresanov4933
@jaxongiresanov4933 2 жыл бұрын
kuchlanishdan himoya qilish
@jerrijerri5527
@jerrijerri5527 2 жыл бұрын
Acha acha hotta hei curry curry use english
@RajeshKumar-my5ml
@RajeshKumar-my5ml 2 жыл бұрын
Kahi nahi milti hai
@Anticurruption5633
@Anticurruption5633 Жыл бұрын
Wrong connection
@shekharpandey2367
@shekharpandey2367 2 жыл бұрын
Total fake knowledge de rahe ho, kisne kaha h ki jiske ghar me earthing nhi h wo SPD use nhi kar sakta aur 3000-4000Rs tak nhi milta maine to 800Rs me kharida kuch din pahle.
@dramasforyou879
@dramasforyou879 7 ай бұрын
Earthing ke baghir spd ka koi faida nhi
@sunrisingsolar
@sunrisingsolar 6 ай бұрын
Bina earthing ke kaise use kare bhai aap bta do
@intek9433
@intek9433 6 ай бұрын
agree​@@dramasforyou879
@mahendrasuna7172
@mahendrasuna7172 10 ай бұрын
To sir SPD ka kam sirf lightning se bachana hai kya
@deepakk1347
@deepakk1347 Күн бұрын
Sir kya hamesa spd connection me DPMCB ke baad lagega ? ya Voltage protector ke baad mi lagana hai?
@neerajvishwakarma8298
@neerajvishwakarma8298 2 жыл бұрын
Good
@tahirabbas130
@tahirabbas130 11 ай бұрын
Good
How Strong Is Tape?
00:24
Stokes Twins
Рет қаралды 96 МЛН
99.9% IMPOSSIBLE
00:24
STORROR
Рет қаралды 31 МЛН
UFC 310 : Рахмонов VS Мачадо Гэрри
05:00
Setanta Sports UFC
Рет қаралды 1,2 МЛН
Solar SPD Secret | Surge Protection Devices
13:24
Sustainable Every Day
Рет қаралды 78 М.
COMO MONTAR CUADRO DE PROTECCIONES FOTOVOLTAICAS - INVERSORES MONOFÁSICOS
11:22
ENERGY SAVING SOLUTIONS
Рет қаралды 239 М.
How Strong Is Tape?
00:24
Stokes Twins
Рет қаралды 96 МЛН