Sup. I am a Residential/Commercial student. I started back in Jan 2020 and graduate April 2021.
@TheGhettoLobster4 жыл бұрын
Yooo Greg come back to the HVAC discord
@Bobherry4 жыл бұрын
@@TheGhettoLobster id love to but I dont have a invite
@brianrwilliams57322 ай бұрын
Straight to the point, thank you.
@jredbokie1247 Жыл бұрын
You guys have helped me soooo much thank you for all you do.
@rickbraden42723 жыл бұрын
Excellent. Thank you. Just ran into this on a change out yesterday.
@alimayah4461 Жыл бұрын
Hello, thank you for your useful and valuable teachings. If possible, it would be better if the movies have English subtitles, thanks
@AlexGarcia-vv4ux4 жыл бұрын
Just seen your company’s reviews online incredible amount of positive comments 300+ . I also saw your job hire requirements and benefits you guys have a great company and great KZbin channel 👍🏼
@HVACS4 жыл бұрын
Thanks!
@timrob04204 жыл бұрын
You should do some of these on a heat pump in HEAT mode, that would be freaking awesome
@Automotive_Solutions4 жыл бұрын
Thanks for the explanation. I'll be checking out more of your videos. 👍
@johnd43483 жыл бұрын
I have a high calibrated hand for measuring line temperatures.
@MrGarcon983 жыл бұрын
with all this usefull info , it reminds me of my teacher alsmost at the beginning of the hvac course ,,,he said air conditionning is not a 100% corrrect science ! and anything within 3 degrees is acceptable in hvac . just saying ,,,,thanks for the info
@josetrevino98694 жыл бұрын
These are good, they help you touch base, strengthens your foundation
@vnesmuonnam3 жыл бұрын
Love all your videos. If you speak little bit slower that will help a lot of new techs. Thank you.
@hvacplayer32384 жыл бұрын
Dude you’re the best.
@troymason47994 жыл бұрын
I had 78 return, 52 suction saturation and 5 superheat on a piston. Humidity within range (68wb). 435psig on high side, 18 td in a commercial place that wasnt cooling.
@hiseminencetheholymacdiarmada4 жыл бұрын
435 psig is awfully high. What system are we talking about here?
@forzamilan073 жыл бұрын
Need some more info... sc? Supply?
@ronniebuchanan65753 жыл бұрын
Sounds like a TXV valve problem.
@j.r.12234 жыл бұрын
Sweet. Greatl video! Thanks
@efco244 жыл бұрын
I have a question. How far from the evaporator does your temperature probe need to be?
@cu27rotary704 жыл бұрын
I went on a call for frozen coil and found five registers closed. One of the boys gets too cold and closes them.
@raidone74132 жыл бұрын
I bet the door is shut when he closes them. Less household airflow. I wonder if an ecm motor will have the same problem
@rosemariejarrett33782 жыл бұрын
Good evening can I use a 12000 btu evaporator coil I got from a 410a system with a r22 condenser also 12000 btu
@rosemariejarrett33782 жыл бұрын
Both from mini split ACs
@jakej814 жыл бұрын
How accurate is mq measured airflow with hygrometers? Could this method be used in heat pump heating mode?
@honestman276 Жыл бұрын
Compact symptoms chart (such as suction and discharged pressures, superheat, subcool, ampere rating, and delta temperature against each indicator or fault. Thanks from Bangladesh.
@SJ-xk5zm4 жыл бұрын
Sir I am from India new cold room cr22k6m compressor starting 35 amps internal trip after 3min starting ok capacitor relay new but same problem please help
@jagsjer2 жыл бұрын
I went on a call the other day. She stated she had three companies out and they said everything looks fine. She said I can’t get the house down below 80° on a 100° day. Gauged up to system with smart probes and saw the Subcool was at 11° as stated on the tag. But say suction temp up and delta t only at 12°. Mins you it’s a down flow application. Filter clean evap was clean as I. Was looking at evap I found that the installers had made a wood frame between the coil and furnace. And it only had 3” of a gap on each side of the coil. ADP coil that had about ten inches of flat space on top and the air would dead head there and only 3” on each side where air would maybe get threw the coil. All in all poor install lead to this lady having issues for the last four years.
@koundridinesh54944 жыл бұрын
Could you please explain ammonia chiller (-15) Why section presser is going to -18.9
@DanBurgaud4 жыл бұрын
As I was cleaning our window type AC unit I noticed it uses 2 capillary tubes as expansion valves going to multiple copper loops in the evaporator. Why not have a single (but long) copper loop? So I took an IR thermometer and measured some of the temps in the evaporator: Return Line (going back to the accumulator): ~ 26c cooper loop: ~ as low as 8c, to as high as 25c unfortunately, I could not measure the temperature on the capillary tubes. Care to make some comments? Thanks!
@alexzapata6924 жыл бұрын
Awesome 👍🏽🔥
@majid86362 жыл бұрын
What are the reasons why the evaporator is half cold, while the other half is a little cold?
@cpaul574 жыл бұрын
How about hydronic forced hot air. The heating coil on the supply is so restrictive
@josetrevino98694 жыл бұрын
On another note how do you feel about testos 417 vanr anemometer for measuring airflow
@sergiomansilla4 жыл бұрын
Good video !!!! Saludos
@PhilipAlonzo3 жыл бұрын
Question anyone why is my fan not going on when i put the thermostat on on or even auto still no air out vents
@dougsanders60342 ай бұрын
Have your capacitor checked.
@smacleod692 жыл бұрын
I bought a testo hot wired anemeter. And it sucks on flex and box systems where you have a 4ft plenum on either supply or return with multiple flex sizes attached to it. For example. I have a supply plenum inside dimensions 15x17 and Im looking for 800 cfm and measuerment might be close. Then I will then input dimensions 10x10 for 400 cfm. Stick the probe in the same 15x17 plenum and will read 350 cfm. That probe is not an accurate way to measure cfm!
@hookedup94243 жыл бұрын
Good morning,I have a question HVAC SCHOOL. What causes no sweat on suction line
@MegaDysart2 жыл бұрын
When the suction line is sweating it is because it is colder than dewpoint and water in the air condenses onto it. Therefore if the suction line is not sweating then the suction line temp is not at or below dewpoint. Not necessarily an indication of a problem, you'd need to evaluate the rest of the system and ambient conditions to determine if there is an issue
@publicmail24 жыл бұрын
I have a 3 ton heat pump my SP are excellent spec is .5 low tap I have .26 so I'm moving a lot of CFM. From the manufacture chart of blower low tap is 1040cfm, med 1302, high 1504 and verified these very close with hood. On high delta is 17 F, med 18.5, low 19.8. humidity is 40% so I wonder what blower speed is best for efficiency. I think the high is moving too much and a little loud on supply, what do you think? I think you can be moving too much air hurting heat removal and humidity capture. I even rigged a wifi switch thru a relay to switch fan speeds remotely on a PSC motor.
@robertcherry49712 жыл бұрын
Medium speed is what you want especially for cooling.
@hewaakrey85813 жыл бұрын
When we use pt chart how we can calculate temperature 🌡 for ac ,coling and freezing How to know what temperature will be to choose pressure of section line
@caru32573 жыл бұрын
in an install, you use the manufacturers guide. in a service call without the manufacturers info, use superheat for fixed orifice and subcool for txv.
@rickcantu45014 жыл бұрын
Great video as usual! Could u make a video on nitrogen pressure testing. Sometimes when I do mine with my resto 557 I do pressure test for 20 min and I see it drop like .4 sometimes .7 , is that acceptable? Could it be an actual leak in system or in my hoses ? I bubble test my hoses and find no leaks. I hate having those doubts Though. But then I pull vacuum to below 500 and decay tests passes
@chinoballa760 Жыл бұрын
That’s totally normal. Sometimes your pressure will go up too if the sun is hitting the unit because with higher temperatures goes higher pressures
@gamewizardks4 жыл бұрын
Will an undersized Evap also cause a low superheat/low suction situation? I'm currently working on a system that is mismatched. The condensing unit is 2 tons and the evap is 1.5 tons. It's an R-22 system and I cannot get the suction pressure above 55 no matter how much refrigerant I add. I am checking superheat and that's why I stopped adding refrigerant, because SH got too low.
@MegaDysart2 жыл бұрын
I know this an old comment but I wish there was a clear answer to this. In my mind, an undersized evap would cause high superheat because the mass flow rate would be lower due to the size. However I'm not sure that's a 100% guarantee because an undersized evaporator might be the cause of low airflow, which could have the opposite effect. Did you ever get this figured out?
@gamewizardks2 жыл бұрын
@@MegaDysart Turns out, in the end, there was a restriction in the coil and it was replaced with a properly sized coil. This system worked perfectly after that. Thanks for the belated response. Cheers!
@samuelg35862 жыл бұрын
Man I wish we actually had enough time to test these things on service calls. That's the biggest problem
@eduardoguardado6999 Жыл бұрын
Amen
@IALewis4 жыл бұрын
👍🏿
@matttzzz22 ай бұрын
High delta T makes no sense. How can you have low airflow but high delta T? High delta T means the aircon is cooling/heating amazingly! Shouldn't it be low delta T?
@abdulhvac23954 жыл бұрын
Man you are very fast .Would you slow down a little bit And make it simpler for a new guy like me
@EricTurock2 жыл бұрын
His speed is perfect, in my opinion of course. You could try using KZbin's built-in playback speed control to slow it down.
@buddyholly89993 жыл бұрын
I would suggest not taking out all of the parts of the videos when you aren't talking. It's too fast to interpret when there are no pauses.
@coldfinger459sub04 жыл бұрын
I just sent this video to a automotive technician in the UK trying to explain airflow problem over evaporator giving you false readings that you cannot trust on your gauges. I hope he comments and replies when he sees this video. HVAC and automotive side gets very little attention and very little education. They need our help.