Good quality construction material makes your home look beautiful inside out. Watch our video to learn the various ways to test the comprehensive strength of concrete.
Пікірлер: 60
@rajvernekar35154 жыл бұрын
Today I casted concrete cube how to measure 7 & 28days strength . When water is added to cement or when cube is put in the water pond. Please clarify the date of testing immediately sir
@akbarAli-dv9by7 жыл бұрын
Its very usefull Today on my construction site i have to do cube mould test and this video is help me lots. Thanks ultar tech
@civilsiteeducation62074 жыл бұрын
Good effort. Cubes are not filled as IS code recommended. Your compaction breach the procedure. Please correct. Regards
@BikashKumar-uc8if8 жыл бұрын
very nice to know the practical knowledge so continue
@ganeshmoorthy43873 жыл бұрын
Please use a scoop for pouring concrete in cube mould
@dinithisahanika78232 жыл бұрын
thank you very much ultra tech cement..i am practicing civil engineer .this helps me lot
@UltraTechCementLimited2 жыл бұрын
Hello Dinithi, thank you for your kind words. Regards, Team UltraTech
@rajkumarbhardwaj17944 жыл бұрын
Very nice information
@AdilKhan-hk3pb8 жыл бұрын
Nice vedios please continuous your work like it
@ashoktyagi12058 жыл бұрын
what a standard of cube moulds that have more than 5mm gap down side. IS 10086 specify ± 0.2mm tolerance. Are these standard moulds?
@zefir73963 жыл бұрын
Wich rule you use to sample concrete ?
@seriburagam3 жыл бұрын
Info yang sangat bermanfaat,,, Terima kasih..
@md.jalaluddin87116 жыл бұрын
Excellent speech.
@vitrovogan96355 жыл бұрын
The videos are good as always.
@UltraTechCementLimited5 жыл бұрын
Hello Vivek, we are glad you think this, for more videos like this, please do visit www.ultratechcement.com . Regards, Team UltraTech.
@lakshmannaik10805 жыл бұрын
For how many days we have to keep for curing just to check 7 days compressive strength ? Please answer ..
@UltraTechCementLimited5 жыл бұрын
Dear Lakshman, please message us your location in detail, our team will get back to you.
@axj40325 жыл бұрын
That slump rod,not tamping rod
@sathamhussain70964 жыл бұрын
Please sent Bs code number cube casting
@AndyWardle4 жыл бұрын
100% correct. Slump rod.
@venkatraaj1375 Жыл бұрын
7/28 days whether it's consider from date of casting or date of curing?
@UltraTechCementLimited Жыл бұрын
Hi Venkat, Thank you for your query. Our experts will answer your question shortly. Meanwhile, you can watch homebuilding-related videos here - kzbin.info Regards, Team UltraTech
@akramraza4516 жыл бұрын
Great Work
@sirajr39504 жыл бұрын
But, sir, why 35 strokes only? Why not less or more?
@yasishivibabydoll2925 жыл бұрын
Cube test 3 days may kitne % 7 days may kitne % details making of video
@dhwaniparekh15434 жыл бұрын
Which is code is follow for casting cube!?
@pratipalvasava43253 жыл бұрын
I've to cast cube of 100mm * 50 mm... There is no mould for this size.. What can I do..??
@UltraTechCementLimited3 жыл бұрын
You don't get mould of this size. You need to tailor make it.
@hunterhrs72386 жыл бұрын
We are doing this in our college Beam cubes
@Xaviergonzalez855 жыл бұрын
Cubes ko pani me kitni der rakhna chahiye
@quietthomas9 жыл бұрын
Why cure them in water? Also, is that aggregate at 1:03 meaning that these aren't pure concrete?
@AbdeenzRock3 жыл бұрын
hydration process
@vendraakhil68766 жыл бұрын
Good explanation
@ภณวิสิฏฐ์นาถรังสรรค์6 жыл бұрын
ขอบคุณครับ
@kaderabdul41796 жыл бұрын
15x15x15 cubes can check slump
@biplabhalder79246 жыл бұрын
No..Slump cone test means it's height test.
@civilconstructionwork37775 жыл бұрын
25 times, not 35 times
@gpemtzmtz43907 жыл бұрын
What is the standard of this test? pleace
@lowkeyzavaldor35925 жыл бұрын
3 scoops then tamp do this 3 times
@sudiptonathpriyom39784 жыл бұрын
35 blows in each layer? Is it 35 or 25??
@AndyWardle4 жыл бұрын
Sudipto Nath Priyom it’s 35 in a 150 mould 25 in 100mm BS
@sudiptonathpriyom39784 жыл бұрын
Get it. Just missed the size of the specimen. Thanks! 👍
@yd_engineer4203 жыл бұрын
But why only 35 why not 40
@yd_engineer4203 жыл бұрын
@@AndyWardle but why only 35? What happen if i hit 45times??
@AndyWardle3 жыл бұрын
@@yd_engineer420 more compaction is fine. Less is not good. Minimum of 35 for 150mm (6inch) cubes. 25 for 100mm (4inches)
@ashishbhatt97966 жыл бұрын
Cube ko water se kitni der pahle nikalna chahiye
@biplabhalder79246 жыл бұрын
Either after 7 days or 28 days before testing
@hocinemadoui63256 жыл бұрын
Can ask you .
@r.ksharma19316 жыл бұрын
Blows 25 times Not 35 times
@biplabhalder79246 жыл бұрын
No. In slump cone test you should 25 blows in 3 layers but in cube mould it will be 35 blows in 3 layers.
@markstott60913 жыл бұрын
35 tamps per layer minimum in 150mm mould, 25 in 100mm mould. Using a tamping BAR not a rod.
@Civilsitework2012 жыл бұрын
@@biplabhalder7924 in slump 4 layer concrete with 25 blows