The GENT Returns | Gent Vigilon Fire Alarm System

  Рет қаралды 1,959

JmFireAlarms

JmFireAlarms

Күн бұрын

The GENT will be back soon. Youll see.

Пікірлер: 13
@THLighting989
@THLighting989 2 жыл бұрын
Spengy video
@sophiemansell2789
@sophiemansell2789 2 жыл бұрын
Love the horn shaped ones had the white one for nearly 11 years and the grey and white one for over 8 years
@staffsemergresp
@staffsemergresp 2 жыл бұрын
Nice to know its not completely dead.
@rowanbawden7783
@rowanbawden7783 2 жыл бұрын
In iur asda the sounders are gent 34203 with kac call points expect in the bakaery
@danjlslong8165
@danjlslong8165 2 жыл бұрын
Hi 👋
@matthewjones9259
@matthewjones9259 2 жыл бұрын
I do love the photoshop image
@uksds3806
@uksds3806 2 жыл бұрын
Hi where did you get the gent from?
@wayneh150
@wayneh150 2 жыл бұрын
hi there! do you know how to disable a device that has an intermittent fault? got a Gent vigilon with a fault on device 18 on loop 1, i have tried diableing it but it keeps seeting off the alarms - i have stopped card 1 and 2 in engineering and that appears to have stopped the fault and alarms sounding while i work out whats going on.... any pointers?
@JmFireAlarms
@JmFireAlarms 2 жыл бұрын
to completely disable it, the only thing i can suggest is removing it. If its a sensor just unclip it from the base while you await a replacement. If its a sounder, MCP or module then youll need to take it off but put the in and out wires in connectors as to keep continuity to the loop flowing. Stopping the cards will have disabled the entire system. If its a real system then you need to start them up again asap. If you cant find the physical location of the device, go to the panel menu and do the following: Test/Eng > Loop > Find Dev > Find device on loop 1 > Start from device 18 > Enter The device LED will be flashing, and the sounder / strobe if present will be operating. Alternitively you could try to reallocate the loop. This will effectively make the panel forget the whole loop and learn all the devices again. Could iron out bugs. To do this its: Test/Eng > Loop > Allocate > Allocate loop 1 hope that helps
@wayneh150
@wayneh150 2 жыл бұрын
@@JmFireAlarms yes dude thank you all good - mouse in the house eating cables haha
@Dime_Bar
@Dime_Bar 2 жыл бұрын
Stopping the loop means nothing is going to work on them loops (Sounders, detectors, I/F units) go to menu, control, disable, device, then when prompted enter the loop and address number then enter.
@Dime_Bar
@Dime_Bar 2 жыл бұрын
You need to reallocate the loops to get them running again, Fingers crossed nothing has changed on the loop eg removed detector and it will say something like allocated 50 devices, starting loop, loop recovered. If something has changed on the loop the it will say something like loop recovery failed then your fucked.
@louiscannell8864
@louiscannell8864 2 жыл бұрын
First
NEW GENT Vigilon Test
7:09
JmFireAlarms
Рет қаралды 4 М.
System test 1 of the new syncro 6000
10:10
red fire and security
Рет қаралды 800
English or Spanish 🤣
00:16
GL Show
Рет қаралды 18 МЛН
My daughter is creative when it comes to eating food #funny #comedy #cute #baby#smart girl
00:17
王子原来是假正经#艾莎
00:39
在逃的公主
Рет қаралды 27 МЛН
SCHOOLBOY. Мама флексит 🫣👩🏻
00:41
⚡️КАН АНДРЕЙ⚡️
Рет қаралды 6 МЛН
C-Tec MFP 2 zone fire alarm panel
7:18
JmFireAlarms
Рет қаралды 2,7 М.
EDWARDS iO 1000 TEST 1
9:05
SimpDoctorProductions
Рет қаралды 510
2023 New Years Fire Alarm BLAST
2:37
JmFireAlarms
Рет қаралды 3 М.
Apollo syncro test 3
14:04
red fire and security
Рет қаралды 18
Unboxing A New Panel from NACA!
11:41
JmFireAlarms
Рет қаралды 1,1 М.
Apollo Discovery System Test #9!
5:18
ObAlarms
Рет қаралды 1,7 М.
Board System Test 331 #FireAlarmFriday
4:15
Fire Alarm 33
Рет қаралды 103
Hochiki.
0:03
JmFireAlarms
Рет қаралды 2,4 М.
Fire alarm test  on Roblox (Gent  Apollo Hockiki ems protec)
4:48
Oliver's Level Crossing Channel UK
Рет қаралды 3,3 М.
English or Spanish 🤣
00:16
GL Show
Рет қаралды 18 МЛН