The Loxone Modbus Extension - without a Template

  Рет қаралды 1,791

The Automation Gym

The Automation Gym

Күн бұрын

Modbus RTU is a great protocol , however a lot of people get turned down if they don't find a template at www.library.loxone.com
In the video I go through how to Connect RS485 ports, baud rate, parity, stop bits and most importantly how to configure the Modbus Registers in Loxone Config.
Loxone Hardware:
shop.loxone.co...
shop.loxone.co...
100A CT Clamp Modbus Energy Meter used:
amzn.to/4cvy8g6
Library Template to be uploaded :)
Any questions, comment below

Пікірлер: 6
@jechtom
@jechtom Ай бұрын
Thanks for sharing. For long-term accurate readings of total consumption, I would probably use the registers from the "Total energy accumulator" section instead. Active Power becomes less accurate with lower poll frequency because it does not know when, if, or how consumption changed between readings. Also, there is a cheaper option: you can connect a pulse consumption meter to a digital input. It can be two or three times cheaper, and you don't need a Modbus extension. The downside is that you need a digital input for each meter, and you can only read consumption.
@theautomationgym
@theautomationgym Ай бұрын
100% agree, do you have any specific Pulse meters in mind? The OB115 also supports pulse metering on the S0, but definitely not the cheapest..
@MrBdegier
@MrBdegier 6 күн бұрын
Very interesting video, thanks! I was wondering how you add more than 1 device. I understand your device was preset to address #1, what if your other device has the same? I am doing my first Loxone project and are about to start adding 3 modbus meters to my modbus extension and wonder if you have some advice!
@theautomationgym
@theautomationgym 6 күн бұрын
Thanks, on most devices you can set the ID/address either manually or via some kind of interface. So the next one will be 2, then 3 etc up to 32 devices. All of them are wired in a daisy chain with a resistor at the end of the line.
@TheMahdifarhat
@TheMahdifarhat Ай бұрын
can you use Modbus rs light switch? as they are way cheaper?
@theautomationgym
@theautomationgym Ай бұрын
Yes, but it does depend on the switch and how configurable the protocol is
Addressable LED with Loxone & ESP32?(£42.77)
26:33
The Automation Gym
Рет қаралды 2,8 М.
Are You Maximizing Your Loxone RGBW 24V Dimmer?
22:35
The Automation Gym
Рет қаралды 2,7 М.
Happy birthday to you by Tsuriki Show
00:12
Tsuriki Show
Рет қаралды 12 МЛН
Kids' Guide to Fire Safety: Essential Lessons #shorts
00:34
Fabiosa Animated
Рет қаралды 17 МЛН
Prank vs Prank #shorts
00:28
Mr DegrEE
Рет қаралды 10 МЛН
Violet Beauregarde Doll🫐
00:58
PIRANKA
Рет қаралды 32 МЛН
Boscoyo IcosaStar Instructional Video
10:24
Boscoyo Studio
Рет қаралды 5
Loxone Virtual Output with Authentication Key
26:24
The Automation Gym
Рет қаралды 3,4 М.
Mastering Modbus: Heat Pump Integration with Home Assistant!
21:02
How To Connect To The Loxone Miniserver
6:19
The Automation Gym
Рет қаралды 9 М.
What is Modbus Communication Protocol? | Basics of Modbus TCP/IP and Modbus RTU
9:16
IT and Automation Academy
Рет қаралды 114 М.
How to use Virtual UDP Inputs
12:04
The Automation Gym
Рет қаралды 1,7 М.
Home assistant with RS485 Modbus RTU wired network
16:18
Progs Pont
Рет қаралды 672
The Powerful Loxone API Connector
13:11
The Automation Gym
Рет қаралды 6 М.
Happy birthday to you by Tsuriki Show
00:12
Tsuriki Show
Рет қаралды 12 МЛН