The main earth neutral or m.e.n. explained

  Рет қаралды 24,076

ELECTRICAL TAFE theory

ELECTRICAL TAFE theory

Күн бұрын

Пікірлер: 33
@johnhannaway5182
@johnhannaway5182 2 жыл бұрын
I’ve been in the trade a long time, this is the easiest to understand explanation I have seen. Well done
@_Zen_Clips_
@_Zen_Clips_ 2 жыл бұрын
I am a new Electrical Apprentice and this is very easy to understand, Thank you.
@troyotapreuis6020
@troyotapreuis6020 9 ай бұрын
15years ago my TAFE lecture did not explain it like this at all. Such a shame this part of an apprentice the lecture brushed over this swiftly. Your explanation shows how important it is and all under 30mins which was also very clear and precise. Thanks 🙏
@praveensivakumar4912
@praveensivakumar4912 3 жыл бұрын
very clear explanation . easy and simple to undersand . thanks mate
@michaelcarter3358
@michaelcarter3358 2 жыл бұрын
Thank you so much for all these videos mate they are invaluable!
@minabenjamin3660
@minabenjamin3660 Жыл бұрын
This video helped me a lot today, thanks a lot mate - appreciate the effort!
@dalescott4570
@dalescott4570 5 ай бұрын
Thank you. Very easy to understand info. But i have a further question. In an off grid system (solar with lightning protection+inverter+generator) where does this link go? Do they all run to the same earth? Is there a way to separate the earths so that lightning or static electricity does not upset the rcd function? Is that even an issue? There is a real lack of info on this subject. Maybe im just looking in the wrong place?
@johnkaisin8887
@johnkaisin8887 Жыл бұрын
The MEN (Multiple Earthed Neutral)
@stonedsloth6367
@stonedsloth6367 Ай бұрын
man eats nuts
@kelsie9912
@kelsie9912 2 жыл бұрын
very handy video thanks! Would be great if you could use a chopstick or something instead of the ruler though because sometimes it's not clear what your pointing to
@martindekker8203
@martindekker8203 3 ай бұрын
You would only have the earth to neutral link attached on your main board though. Not on any sub boards. correct?
@Mike-me3sp
@Mike-me3sp 2 жыл бұрын
I'm doing a generator connection to my house, and as I'm sure you know the neutral now also goes through the changeover switch (been a few years since I've done one). The question is, do I need a earth-neutral connection at the generator inlet as I'll obviously be losing the men connection when switched over to the generator?
@ifell3
@ifell3 2 ай бұрын
Should the MEN link be thick, least resistance or thinner making a higher resistance? I'm thinking thicker so the current can pass through quicker and the resistance of the other metals in the housing will allow for that 5 or 10 ms delay. Am I correct?
@stonedsloth6367
@stonedsloth6367 Ай бұрын
that depends on on the wiring rules. A dummy value is having it the same csa as the neutral conductor, but there are variations to consider in varying the size. theres also a rule stating a conductive enclosure needs bonding equivalent to that of the neutral conductor. Imagine seeing a 16mm2 bond on a domestic board wtf hahah. But like i said there are variations to factor in that can either increase that size or decrease.
@petergolias7265
@petergolias7265 Жыл бұрын
Thank you So much Sir .
@zhaobingma8240
@zhaobingma8240 3 жыл бұрын
MEN= Multiple Earthed Neutral. Refer AS3000/2007 clause 1.4.66
@damonjenkins2185
@damonjenkins2185 3 жыл бұрын
Should be using as3000 2018
@genesismarsh-potini4153
@genesismarsh-potini4153 5 ай бұрын
Why is it “multiple” why can you only have one
@johnnyambi550
@johnnyambi550 Жыл бұрын
During earth fault condition if nuetral is connected to earthing bar would the current not be of shock harzad
@_Zen_Clips_
@_Zen_Clips_ 2 жыл бұрын
does the MEN link take the risk of Earth leakage away or lowers it?
@electricaltafetheory2197
@electricaltafetheory2197 2 жыл бұрын
Lowers it
@tahaali3603
@tahaali3603 Жыл бұрын
thanks alot
@donnelly.1969
@donnelly.1969 2 жыл бұрын
if the MEN Link is missing is it a serious problem
@xdrcx
@xdrcx 3 жыл бұрын
There's a few things I'm missing here. Why doesnt a little/all current flow from the neutral bar through MEN link to ground? I was under the impression this path is super low resistance. Also where does current go once going to the mass of the earth? Does this diagram show it going back up the power pole?
@timg6850
@timg6850 2 жыл бұрын
The reason the Neutral and Earth wires are connected together via the MEN link is : 1) To make the sure the Neutral is at the same Potential as the Earth Stake in the Physical Earth (0 Volts). 2) To create a path of low resistance for Fault current via the Neutral to the Transformer so a large enough current will flow to trip the Circuit breaker. In normal operations little to no current flows through the Physical Earth as the resistance of the Physical Earth is very high.
@allanbolton606
@allanbolton606 4 жыл бұрын
Nice
@Mike-me3sp
@Mike-me3sp 2 жыл бұрын
Only one complaint; please use something pointier as a pointer 😁
@damonjenkins2185
@damonjenkins2185 3 жыл бұрын
I believe traditional earthing is made redundant by MEN
@stonedsloth6367
@stonedsloth6367 3 жыл бұрын
its just there as a fail safe.
@David-lr2vi
@David-lr2vi Жыл бұрын
Traditional earthing via an earth stake is there to protect the electrical installation (wiring etc) from lightning, not for protecting appliances and people. If protecting appliances and people is all that is required then a path to earth isn’t strictly necessary, although it does provide some redundancy in case of high resistance or open circuit on the neutral. Electric current will always try and return to where it came from, if it came from the pole transformer it will try and return to the pole transformer (through the neutral wire or the earth stake if there isn’t a path back through the neutral). If it came from the ground (lightning) it will try and return to the ground.
@petergolias7265
@petergolias7265 Жыл бұрын
When using RCBO for final sub-circuits, do we connect M.E.N in the sub-board?
@brianfirth5435
@brianfirth5435 Ай бұрын
You know the subject obviously. But what a lot of waffle, not very well delivered.
@aaronr5555
@aaronr5555 Жыл бұрын
Ummm m.e.n doesn’t stand for main earth neutral 🤪
fault loop impendance as/nz 3000.2018 explained
7:03
ELECTRICAL TAFE theory
Рет қаралды 11 М.
Shared or Borrowed Neutrals on Mains Electricity Circuits
18:15
John Ward
Рет қаралды 370 М.
How I Did The SELF BENDING Spoon 😱🥄 #shorts
00:19
Wian
Рет қаралды 37 МЛН
English or Spanish 🤣
00:16
GL Show
Рет қаралды 6 МЛН
لااا! هذه البرتقالة مزعجة جدًا #قصير
00:15
One More Arabic
Рет қаралды 52 МЛН
This Dumbbell Is Impossible To Lift!
01:00
Stokes Twins
Рет қаралды 34 МЛН
High impedance neutral concept
35:18
Matt K
Рет қаралды 19 М.
Maximum Earth fault loop impedance
27:21
JPElectric
Рет қаралды 10 М.
TEST OF ELECTRICAL INSTALLATION  CHISHOLM
20:19
ELECTRICAL TAFE theory
Рет қаралды 7 М.
Does Current Flow on the Neutral?
23:03
Electrician U
Рет қаралды 1,1 МЛН
Diverted neutral Currents -  Is our electricity supply safe?
14:22
RCDs: Neutral - Earth Faults
11:32
John Ward
Рет қаралды 444 М.
Crucial Knowledge To Heat Pump Troubleshooting
14:15
Jersey Mike HVAC
Рет қаралды 27 М.
Loop Impedance Testing
15:04
John Ward
Рет қаралды 288 М.
Overcurrent, Overload, Short Circuit, and Ground Fault
6:54
Dave Gordon
Рет қаралды 852 М.
The Complete Guide To RCDs - Residual Current Devices
21:05
How I Did The SELF BENDING Spoon 😱🥄 #shorts
00:19
Wian
Рет қаралды 37 МЛН