The single mod SPD they didn’t tell us about!!!

  Рет қаралды 63,261

CJR ELECTRICAL

CJR ELECTRICAL

Күн бұрын

Preparing Consumer unit. Does it save you time and money rather than doing it on the job?
Il still have to install glands for cable entry and other various modifications.
10% discount at consumer unit world on all accessories and Fusebox range CJR10
www.consumerun...
Thanks for watching
Instagram follow me please I’m desperate.
/ cjrelectrical
This video is for entertainment purposes only please do not attempt to copy or recreate this video in any way.

Пікірлер: 279
@johndevine6288
@johndevine6288 3 жыл бұрын
What I liked about this video is that a picture paints a thousand words and moving pictures even better. I could see how everything was fitting together and not have any audio anoying anyone else in the room. Keep the videos coming and some merit having no sound. Cheers Chris 👍👍👍
@farley1992
@farley1992 3 жыл бұрын
must admit i prefer the talking episodes of this dramatic tale
@Marco-mg9tv
@Marco-mg9tv 3 жыл бұрын
Top tip - if fitting the tail gland on the bottom of the board like that do yourself a favour and bin the rubber . They are far too tight so if you are struggling do without it you will achieve in excess of required IP2X. You really don’t need the ip68 that it provides with the rubber inserted !
@Richardincancale
@Richardincancale 3 жыл бұрын
No problem reading your upside down caption - reading upside down is a trick I learnt sitting opposite my boss!
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
Haha at the paper no doubt.
@jordankai574
@jordankai574 3 жыл бұрын
@@Cjrelectrical What is your level of qualification?
@supersparks9466
@supersparks9466 3 жыл бұрын
@jordan Kai he’s a qualified plumber
@Rosscoff2000
@Rosscoff2000 3 жыл бұрын
I like spacing modules to reduce temperature build up, but using whole body blanks to do it limits the benefit. I think they should make those in a skeleton format that allows more ventilation between modules.
@thechillingvillan
@thechillingvillan Жыл бұрын
love this idea, wont be long before someone 3d printing them
@Chris_In_Texas
@Chris_In_Texas 3 жыл бұрын
Its so nice not having to deal with neutral tails with newer panels here in the US. With both the hot and neutral having plug in neutrals, so those are just wired into the breaker and plugged in, connection done. Heck Leviton has gone one step farther in that no wires go to the breakers anymore and they are simply inserted into the panel to complete the circuit. They can be fully wired during the rough in phase (1st fix) and then during final install (2nd fix) all that is done to activate the circuit is plug the breaker in which can be standard (MCB), AFCI, GFCI or combo AFCI/GFCI breakers. Makes the install clean and not having to deal with the breaker tails anymore.
@oldbutstillcurious3615
@oldbutstillcurious3615 3 жыл бұрын
Interesting development by Leviton. ? Are you saying that simply unplugging a breaker from a board isolates both the hot and also neutral conductor of the outgoing cable associated with that breaker?
@Chris_In_Texas
@Chris_In_Texas 3 жыл бұрын
@@oldbutstillcurious3615 Yes that is correct. Pulling the breaker will cut out the neutral as well, as all slots are setup for AFCI/GFCI breakers. With the newer 2020 code just about every breaker will be AFCI and many now including a good selection of the 240V ones will be GFCI as well in any damp/wet areas.
@12000gp
@12000gp 3 жыл бұрын
@@Chris_In_Texas nice to hear how other countries do things, out of interest how much is an AFCI/GFCI breaker where you’re from?
@oldbutstillcurious3615
@oldbutstillcurious3615 3 жыл бұрын
@@Chris_In_Texas Thanks for the update, much appreciated.
@chrisclode6410
@chrisclode6410 3 жыл бұрын
That was a serious case of ASMR mate lol
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
👌🏻
@jordankai574
@jordankai574 3 жыл бұрын
@@Cjrelectrical What is your level of qualification?
@barryturner1146
@barryturner1146 3 жыл бұрын
Y dont james wirk with andy?
@Marco-mg9tv
@Marco-mg9tv 3 жыл бұрын
Might seem a good idea but from experience you can’t fit a board fully or part populated and make a good or quick job out of it . As I’m sure Chris knows it’s best to strip the board bare , get your knockouts and cable management , grommets and glands in place, then get your final circuits, meter tails earth and bonds in, dress your cpc,s then put your din rail in, and in an all rcbo board install and terminate one device at a time. That’s what I do anyway !
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
We shall see this board is being installed
@Marco-mg9tv
@Marco-mg9tv 3 жыл бұрын
@@Cjrelectrical cool will be interested to see how you get on. The Compact rcbo’s will be a help. Look forward to watching that one ☝️
@MkElect2011
@MkElect2011 4 ай бұрын
Yep, I do the same.
@tresslerj1985
@tresslerj1985 3 жыл бұрын
Not sure amperage is a UK term for the current rating of a device.
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
Thanks John your comment is most helpful.
@SeanBZA
@SeanBZA 3 жыл бұрын
Nice on the "please check screws after installing" because pretty much every time I go into a panel half the screws are loose, or just not tight, so half the flickering light issues vanish with that check. Yes to the spacers, nothing worse than looking at the panel, and wanting to put one more breaker in, and having to play breaker roulette to move them all one space over, and finding that one breaker that is wired with an exact length of wire, and it will not move, so you have to play leap frog over it. Or open the panel, and the council sparktrician has been in there, and decided that breakers are not needed, so fed the incoming mains in to the bottom of the RCD, and used the isolator instead to feed a circuit. Good thing there was the main 100A breaker right below it, with it's loose screws, and no cover either. Tightened them up as well, but the meter is just going to have to stay as is, there they actually used a seal.
@mrgfromoxford8644
@mrgfromoxford8644 3 жыл бұрын
Fitted my first one the other day , everything was great except the rcbo , found when tightening the grub screw onto line and neutral cable the rcbo felt weak and distorted and even broke . The Hager doesn’t do that !!! Yes I was using a torque screwdriver.
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
First time I’ve heard that
@davidb3537
@davidb3537 3 жыл бұрын
I've had issues with the tripping times on these boards had to return a couple of RCDs a year or so back, I made no circuit alterations, just replaced the RCDs with new, trip times were then fine when then tested. These were new installations with no loads applied.
@Mattja1
@Mattja1 3 жыл бұрын
@@Cjrelectrical I've not used the fusebox mini RCBOs yet, but find the same thing on many I have used, have to squeeze the device to stop it coming apart when tightening the screw.
@mrgfromoxford8644
@mrgfromoxford8644 3 жыл бұрын
@@Mattja1 that’s exactly what I experienced. Anyway I gave them a chance but for the sake of a few quid I’m going back to Hager , they never fail in any department
@mrgfromoxford8644
@mrgfromoxford8644 3 жыл бұрын
I did hear from my wholesaler yesterday Hager prices are going up 10% cos of brexit . I hope everyone who voted to leave 4 years ago is happy now 🤬
@williamyates2794
@williamyates2794 3 жыл бұрын
The best video you’ve done you can usually hear you blowing your own trumpet 🎺
@oldbutstillcurious3615
@oldbutstillcurious3615 3 жыл бұрын
He plays a good tune, in my opinion.
@emilmckellar4932
@emilmckellar4932 3 жыл бұрын
I know those as bootlace lugs, ferruls I know as the crimp connectors we use to use between two cables. Why do you not use a hydraulic crimper and pin lugs on the 16mm^2 and above and heat-shrink? Takes a bit longer but make for a much nicer finish and more secure.
@MkElect2011
@MkElect2011 4 ай бұрын
Can’t see the point in putting blanks in between the rcbo’s looks much better all in one line with blanks at the end. Also why trim neutral fly leads, just loose excess behind main switch.
@G8TIC
@G8TIC 3 жыл бұрын
Early preparation is good... this looks like a classic case of PPPPPP ... Perfect Preparation Prevents Piss Poor Performance
@acespark1
@acespark1 3 жыл бұрын
Ready for the kitchen fitter to throw it in for you 👍🏻
@markandrews8437
@markandrews8437 3 жыл бұрын
Enjoyed that matey like the demos it helps us less experienced guys 👍
@nw5835
@nw5835 Жыл бұрын
Only just seen this, well done James, Chris is a good boss with logic and common sense.
@vinigoalkeeper3009
@vinigoalkeeper3009 3 жыл бұрын
This comment section has had me in stitches 🤣🤣🤣🤣 Chris’s level of sarcasm is fantastic
@darkdepth1991
@darkdepth1991 3 жыл бұрын
Wiha LiftUp electric 6 in one, my fav tool. Together with the Wiha LiftUp 26one and a few pliers/ratchets/sockets/knifes what I have on me all day.
@pyrounlimited7035
@pyrounlimited7035 3 жыл бұрын
As for a industrial electrician the 6 in 1 pop up is a crap tool not up to dayly abuse
@Matt-bt7ej
@Matt-bt7ej 3 жыл бұрын
Hopefully not long until RCBO boards with Line and Neutral bus bar come along and get rid of those fly leads😁
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
We can only hope.
@MrPutty69
@MrPutty69 3 жыл бұрын
Was it a Sponsored silence Chris day?😂
@daron8982
@daron8982 3 жыл бұрын
The silence of the lamps
@rayc1503
@rayc1503 3 жыл бұрын
Excellent tutorial, straight to the point 👍. More of these please 🤗
@chrisrogers2848
@chrisrogers2848 3 жыл бұрын
Interesting video to see you build it all up in detail, but a bit odd without the usual commentary. How do the dummy modules compare on price with standard blanks? Do the benefits justify the extra cost?
@paul_my_plumbs_uk
@paul_my_plumbs_uk 3 жыл бұрын
Any good electrician would no that single pole module spd's are out there 😂😂😂😂 ❤️❤️❤️ you man
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
For youtube kid
@paul_my_plumbs_uk
@paul_my_plumbs_uk 3 жыл бұрын
@@Cjrelectrical joking with you 😉😉😉
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
I know
@buckshee
@buckshee 5 ай бұрын
Slightly strange question, the position of the SPD, does it have to be where it is or can it be anywhere along the DB? I know having it there looks nice however I’ve had occasions where putting it at the other end or where there is a spare way would make the instal easier.
@notbadforasparky4791
@notbadforasparky4791 3 жыл бұрын
This isn't a statement just towards you Chris and anyone feel free to chip in. I've been watching you and the other electrician 'stars' for some time now, so I have seen the progression and fads flow through the scene. By that I mean everyone starting to use things like wagos, ferrules and also flexi tails. Some do it right, some do it wrong. i.e. ferrules are meant for fine stranded cables, but some seem to think they are needed on things like 6mm and 10mm twin. Yes they are stranded conductors, but not FINE stranded. Anyway to the point...... Flexi Tails. Now I've never used flexi tails personally, but I can only imagine they are so flexible because they are fine stranded. Yet no-one is putting ferrules on them??? Surely they should be ferruled. Discuss Cheers for the content btw. Lve a bit of CJR, ok.
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
Your correct everyone man and his dog is even fitting them on 10mm solid stranded twin and earth. They are indeed only for fine stranded like on the rcbo fly leads. It also doesn’t say you can’t put them on other cables ie solid stranded does look neater. Flexi tails are still solid just more inner cores.
@farmersteve129
@farmersteve129 3 жыл бұрын
Most incomers etc have proper clamp terminals so the copper will generally form itself into a good fit compared to where wires go into busbars etc that rely on the screw tip which generally just pushes the wires to the sides. I have used crimps where flexi tails go into Henley type blocks that rely on screw tips rather than having proper clamps.
@notbadforasparky4791
@notbadforasparky4791 3 жыл бұрын
@@Cjrelectrical Cheers for the reply mate. Just actually looked at flexis on TLC website and they are 19 strand, so each core i guess is about 1.3mm on 25mm tails. I have visioned them to be like tri-rated stuff, but like you say, they aren't that fine really. Thanks again bud
@inputimmersion9577
@inputimmersion9577 3 жыл бұрын
For me, if they're being tightened down with a screw rather than a clamp type fitting they are always getting ferruled regardless of size. That's how they do it on the continent and it's much neater and stops the strands flailing out.
@jneale7715
@jneale7715 3 жыл бұрын
Just when I though your videos couldn't get any better... Then you do one without talking 👍🏻 Joking!
@ItzD3fW1sH
@ItzD3fW1sH 3 жыл бұрын
Trying to branch out into the ASMR game are we Chris? 😂
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
Yes hopefully
@apmullen
@apmullen 3 жыл бұрын
But great stuff and great boards, would like to see a magnet on the lid !
@TheMattSturgeon
@TheMattSturgeon 3 жыл бұрын
Not 100% sure how true this is, but think the metal lid is supposed to close automatically in order to maintain fire integrity. I guess the theory is that if the lid was held open a fire could escape through the plastic breakers & blanks.
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
You are correct
@acelectricalsecurity
@acelectricalsecurity 3 жыл бұрын
@@TheMattSturgeon doesn't really matter, I have seen boards with the cover hinged on the side and some that drop down
@acelectricalsecurity
@acelectricalsecurity 3 жыл бұрын
I bought a pack of small magnets from eBay that I leave on each board, not sure how long they will be there for though, until someone moves them 😂
@Emin3m1986
@Emin3m1986 3 жыл бұрын
Yeah, Schneider does that with their boards, adds a little magnet. Which is not a bad idea, but that’s because their boards are hinged down. On this type of board you don’t need any magnets, but again, it’s not a bad idea.
@willmurphy6663
@willmurphy6663 Жыл бұрын
thanks a really clear video i appreciated just showing, and typed instructions and no chat...
@chriskirby3337
@chriskirby3337 3 жыл бұрын
Why can't we have twin busbar boards. One line one neutral? Would get rid of the bloody flying neutral leads, making a much neater board.
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
Yeah would be nice but room is tight
@chriskirby3337
@chriskirby3337 3 жыл бұрын
They can do it in France. Why not here? 2 busbars offset on the bottom of the breakers. I was fitting A type Rcd's there 10 years ago. We are a little behind the times in this country
@kittsdiy
@kittsdiy 3 жыл бұрын
@@chriskirby3337 In Belgium also .. we don't have neutral bars . Al dual pole brakers .. crazy how smal fuseboards are in uk .. we need at least 2x the size ..even more .. since we never used the stupid ring circuits .. all radials here on 20A type A MCB
@dg2908
@dg2908 3 жыл бұрын
you can get them from sbstradesales
@inputimmersion9577
@inputimmersion9577 3 жыл бұрын
@@chriskirby3337 Can confirm. In France, 2 bus bars straight into the mcb's fed by the tails coming from the meter. Very easy, much quicker, much neater. UK has a very weird way of doing things including rings mains.
@danyo1972
@danyo1972 10 ай бұрын
Nice, good info here for anyone looking at a Fusebox SPD board. Thanks.
@betosr71
@betosr71 Жыл бұрын
Hello, what device is this on the left side of the Rcbos? I live in Brazil and I don't know this device. Thank you very much.
@gizmo6164
@gizmo6164 3 жыл бұрын
Ha, the Marcel Marceau of the electrical world! 👍🏼
@RichardArblaster
@RichardArblaster 3 жыл бұрын
That "clunk" sound as they go in is very satisfying 😎
@itsmyview2024
@itsmyview2024 3 жыл бұрын
I like spot the difference competitions soooooo The neutral rcbo connections look to be a couple of position out, first one on the left should have been in position15 surely? A very very small amount of cable pulling gel on the tails make pushing them into the gland a bit easier
@paulg6858
@paulg6858 3 жыл бұрын
13th cct breaker = neutral terminal 13. But shouldn't the manufacturer fitted SPD's neutral be in neutral terminal 1?
@itsmyview2024
@itsmyview2024 3 жыл бұрын
@@paulg6858 depends where you start counting, its an a8 bay board plus the spd which has its neutral in the scond N, then count from there 1 and 2 are the main switch's terminals?
@SultansKitchen1
@SultansKitchen1 3 жыл бұрын
Good Job Chris, thanks once again for the brilliant demo😊 I hope you sleep well at night,🤣 I've done my part.👍🏼
@Randrew18
@Randrew18 3 жыл бұрын
Loving the ASMR vibe you got going on in some of your videos! Thanks for the content. I didn’t realise you could shorten the fly leads, someone told me you aren’t supposed to but i don’t see why it would be an issue.
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
Spoken to technical it’s fine to shorten the length as long as you use a suitable crimp on the end.
@stuartrhoades4306
@stuartrhoades4306 3 жыл бұрын
Personally I think is completely unnecessary to shorten them, but each to their own.
@PlanetCypher_
@PlanetCypher_ 3 жыл бұрын
Do you sleep upside down then?😄 Looks like good kit, why do you like Fusebox Chris?
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
It’s the most cost effective spd rcbo consumer unit on the market
@richardbushnell1065
@richardbushnell1065 3 жыл бұрын
@@Cjrelectrical i am buying Lewden and its cheaper from my wholesaler
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
Cool
@davidb3537
@davidb3537 3 жыл бұрын
I'm using contactum boards at the moment, comparable prices and made in the UK ( apparently)
@robskiing
@robskiing 3 жыл бұрын
@@richardbushnell1065 I've used lewden and fusebox and I think the latter is far superior imo
@southseaelectrics6236
@southseaelectrics6236 3 жыл бұрын
Those Wiha drivers look the part but the plastic holders inside break after 3 months. I gave up after 3 broken ones.
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
Ahh that’s a shame mate mines been good as gold.
@Mr.Eldric
@Mr.Eldric 3 жыл бұрын
Why do they all have blue wire attached. I aint a sparky. So no clue. Just my fuse box at home does not look like this. All the neutrals are in a line at top. Whats gan on please
@Zeamus634
@Zeamus634 3 жыл бұрын
What do you mean the ferruls don't work???
@fatpedro5588
@fatpedro5588 3 жыл бұрын
Is there a colour coding system to ferruls?
@mattknight142
@mattknight142 3 жыл бұрын
Yes at the very least french and German colours
@alanisaac9114
@alanisaac9114 3 жыл бұрын
Nice video Chris👍also what screw driver was you using ?
@keithfoster6000
@keithfoster6000 3 жыл бұрын
No such word as AMPERAGE. Current rating!!!! I would have got a right bollocking when I was at college for using that term
@ianyanto123
@ianyanto123 3 жыл бұрын
found this very relaxing to watch! great video!
@farmersteve129
@farmersteve129 3 жыл бұрын
One thing that I find missing on most of the basic board designs is that I would prefer to see a fixing on the busbar cover so that it doesn't drop out & is more of a definite action when removing it.
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
Yeah even the really old modular boards had screws on the cover.
@acelectricalsecurity
@acelectricalsecurity 3 жыл бұрын
To be fair the bus bar covers in these boards are in quite firmly, they are not like most of the others.
@dg2908
@dg2908 3 жыл бұрын
Do you find that buying 3m tail packs works? I'd sooner buy 10m of each which could might do 6 or 7 boards and it cuts down on waste Edit: I don't prep mine in advance apart from checking I've got all the bits. I realise that time at home on the bench is always easier than time on site; I'm not quick on site but I do have a penchant for getting things absolutely spot on, and with a board change I find you never quite know the best way to do things until you're in the middle of it
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
Yeah love the 3m packs stops you going over length 🤣
@t2ringer
@t2ringer 3 жыл бұрын
Can those dummy mcbs be easily removed/refitted when the busbar is on? If so then putting one in front of the middle screw on the din rail would enable a fully loaded din rail to be removed/refitted to make installing the tails easier.
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
Yeah they come out easily just push down the din rail clip
@Simonsimps
@Simonsimps 3 жыл бұрын
Thought I'd accidently clicked on a @my mechanics video with the gentle sliding of parts across the table. Nice video Chris. Cheers.
@kevinlangston8465
@kevinlangston8465 3 жыл бұрын
Love that screwdriver. Where do you get it from?
@zakinster1
@zakinster1 3 жыл бұрын
I had the same question but I think I found it, seems to be the Wiha Lift Up (ref. SB 283109021, you can find it on Amazon it's the article B00GY0Z45G)
@Ghosthuntert1
@Ghosthuntert1 3 жыл бұрын
Chris, Not speaking is creeping me out, I keep expecting Christopher Lee to jump out and say " BOO!"...
@williamsanter1153
@williamsanter1153 3 жыл бұрын
Why do you leave inner insulation showing when terminating tails? I see this all the time and just wondered.
@Rosscoff2000
@Rosscoff2000 3 жыл бұрын
Gives an easy visual check on correct phase identification. And of course makes them more flexible for the tight turn into the isolator.
@g.williamswilliams8442
@g.williamswilliams8442 3 жыл бұрын
Great video Chris : Two observations: 1. I'm not a fan of the rcbo spacing,... looks a bit d/p isolator...ish...( could be deceiving to the " end user ").. hey ho., just me.. 2. Missed your vocal commentary
@stuartlong8695
@stuartlong8695 3 жыл бұрын
Someone should get you a sonic screwdriver. Who you say. Call the doctor as the cat it seems has got your tongue
@vernonjones2115
@vernonjones2115 11 ай бұрын
Well done chaps great content useful tips
@davidelmer2502
@davidelmer2502 3 жыл бұрын
Great video chris, This is how you do it.
@davidarcher9371
@davidarcher9371 3 жыл бұрын
Cat got your tongue Chris? Seriously though, enjoyed the watch
@UberAlphaSirus
@UberAlphaSirus 3 жыл бұрын
You made me buy that 6 in 1 whia for my test bag, your such a little influncer, lol. My 5 year old thinks it's amazing. Be nice if they done a tourqe setting one, They call it vario. Anyhow, thanks for the tinitus.
@imark7777777
@imark7777777 3 жыл бұрын
I would love to know how many people flip their laptops over? And how many read it upside down? And how many people watching on phones and equivalent rotated it around and around and around........
@sparksPRW
@sparksPRW 3 жыл бұрын
Very moody, almost silent Chris....great idea to plan ahead while you are catching up on the soaps, Cheers useful as always.
@paulbritton187
@paulbritton187 3 жыл бұрын
Nice video Chris, but I was taught that you shouldn't twist the strands together when fitting ferrules on wires, they should follow their lay in the wire as much as possible.
@HerbieHewitt
@HerbieHewitt 3 жыл бұрын
Why? We're only talking a few mm so what difference would it make?
@Cablesmith
@Cablesmith 3 жыл бұрын
I think the new fusebox units have dropped in quality slightly, do you ? I hate the new cover especially
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
No if anything the fit better and don’t leave that little 2mm gap now on the last mcb/rcbo
@Cablesmith
@Cablesmith 3 жыл бұрын
@@Cjrelectrical it’s the flap that bugs me. I used to like the lip that was easy to grab. Now you need nails to open it 😀
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
Screw a door handle on it?
@Cablesmith
@Cablesmith 3 жыл бұрын
@@Cjrelectrical 🙄 I’m not having a go you know Chris 😂 I fit them still.... even used your code once 👀😂
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
Yeah I know mate just banter
@haydenuk02
@haydenuk02 3 жыл бұрын
Great work and thanks for the awesome content stay safe and take care
@leebutterworth7465
@leebutterworth7465 3 жыл бұрын
Chris have you lost your voice?? I’ve fitted a couple of the new single module SPD FuseBox consumer units over the last couple of weeks can’t fault the quality of the boards and the RCBO’s are very consistent with trip times
@davidpatterson1574
@davidpatterson1574 3 жыл бұрын
Excellent presentation
@lukesmith8792
@lukesmith8792 3 жыл бұрын
I like your change of video, very nice
@barryturner1146
@barryturner1146 3 жыл бұрын
Y dont james work with andy?
@johnyenagritis8136
@johnyenagritis8136 3 жыл бұрын
hey chris can u give me a link to that screwdriver that u use in the video? thanks
@wheelerqgm
@wheelerqgm 3 жыл бұрын
Is this AMSR ?
@rayc1503
@rayc1503 3 жыл бұрын
Autonomous sensory meridian response. Kind of like a brain massage without physically having one. I guess you could say by watching or listening to something comforting of soothing.
@wheelerqgm
@wheelerqgm 3 жыл бұрын
@@rayc1503 I never asked what it meant
@Jordan-yc3fs
@Jordan-yc3fs 3 жыл бұрын
Wish they would make the neutral leads more rigid to dress even better
@leebutterworth7465
@leebutterworth7465 3 жыл бұрын
I took all the neutrals behind the tails clamp and zippy tie them to the neutral going from the bottom of the main switch to the neutral busbar looks exceptionally neat
@JimWhitaker
@JimWhitaker 3 жыл бұрын
Is it really worthwhile buying the "pack" of meter tails, rather than buying three reels and cutting as required?
@12000gp
@12000gp 3 жыл бұрын
A drum of meter tails is very heavy to carry around, I’ve always bought it in 10 meter cuts but I can see why people buy a new small pack for each job
@philipsmith0752
@philipsmith0752 3 жыл бұрын
whats the mater Chris ? the cat got your tung ?
@09weenic
@09weenic 3 жыл бұрын
Good god Chris is this video in tribute to the late great Charlie Chaplin 😃
@jamieweir3080
@jamieweir3080 3 жыл бұрын
Nice video. What type of driver was that you were using?
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
Just a wiha multi for initial installation
@taxisteve60
@taxisteve60 3 жыл бұрын
Though you were going to tell us something interesting about spd I'll never get that 12.09 back🙄🙄🙄🙄😕😕😕
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
Yes it’s single mod
@apmullen
@apmullen 3 жыл бұрын
I disagree with your comment with the smaller boot lace crimp, same size of cable on all RCBO's from the manufacturer.
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
Nope check again the pvc is thicker on the 6amp meaning the copper is smaller. I bet you £50.
@apmullen
@apmullen 3 жыл бұрын
@@Cjrelectrical Looks like you got me on that one, happy to be educated and save £50 But I will check and stick by the magnet for the lid. Cheers
@arniewheeler4673
@arniewheeler4673 3 жыл бұрын
only a Question, not being critical, is it a requirement to leave spaces between rcbo's or just good practice.. heat etc?
@brianhewitt8618
@brianhewitt8618 3 жыл бұрын
no requiremet that im aware of, only a manufactureer thing, so you shouldnt mix and match and only keep the brands the same
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
Personal preference
@TheHawkeye001
@TheHawkeye001 3 жыл бұрын
(Non-electrician) is it standard practice to recommend customers purchase a spare mcb/rcbo or 2? Just thinking if adding a new circuit years down the line, how easy would it be to get hold of mcb/RCBO's?
@harveytilbury1432
@harveytilbury1432 3 жыл бұрын
Lol you put the company name I work for in the thumb nail
@RaithUK
@RaithUK 3 жыл бұрын
Lol some one almost told us about the single mods.. im sure Bundy got one ahead of the main launch.
@Chris-uu6dg
@Chris-uu6dg 3 жыл бұрын
Great video thanks!
@garethmurgatroyd5447
@garethmurgatroyd5447 3 жыл бұрын
Cat got your tongue 👅
@hamidbazmi7948
@hamidbazmi7948 3 жыл бұрын
What are those Dummy modules for?
@jammyb2008
@jammyb2008 3 жыл бұрын
Forgive me, but how is this single mod SPD? Still needs an MCB to connect it? The end result still takes up the same amount of ways in the end doesn’t it?
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
No the other boards had a twin spd and an mcb which turned a 14way board into a 13 this single mod spd gives you the full 14 ways even with the mcb for the spd
@jammyb2008
@jammyb2008 3 жыл бұрын
@@Cjrelectrical gotcha. That’s a lot taken up in that method. The ones we use and Hager have it wired into main switch so only takes up two ways.
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
Yeah fusebox did do that but then there is something written down about not relying on the dno fuse for overcurrent protection on the spd Hager have just ignored it I believe.
@mikeselectricstuff
@mikeselectricstuff 3 жыл бұрын
@@Cjrelectrical Or maybe the Hager SPD has a suitable internal fuse
@wilsonluilui
@wilsonluilui 3 жыл бұрын
why you cut off the neutral CABLE it have A original ferrule,but it will make the power UP at this SHORT of Low resistor.♎️
@metrotechguru5863
@metrotechguru5863 3 жыл бұрын
Very nice vid mate.
@cosme3345
@cosme3345 3 жыл бұрын
Estupendo trabajo, Saludos
@stuartarrowsmith8889
@stuartarrowsmith8889 3 жыл бұрын
Screwdriver???? Want one 😊
@harjmalhi
@harjmalhi 3 жыл бұрын
TheRelaxingEnd
@dennisphoenix1
@dennisphoenix1 3 жыл бұрын
I wouldn't fit anything into the board until all the holes were drilled , cables glanded etc and it was on the wall . Any dust or metal swarf could get into the rcbo's or the switch . Also if you have slack on the twin cables I would put the heaviest circuits next to the switch. That's just my preference
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
Yeah I agree only saving grace there’s no holes to drill in metal only knock the pre pressed holes out and for brick dust I can mark and remove before drilling.
@oldbutstillcurious3615
@oldbutstillcurious3615 3 жыл бұрын
@@Cjrelectrical ? Vacuum plus straight nozzle, folded thin cardboard over adjacent electrics ?
@rannopaul4711
@rannopaul4711 3 жыл бұрын
Better to bend tails to shape before cutting.
@dannyroberts8822
@dannyroberts8822 3 жыл бұрын
Easiest way is to strip them, bend them to shape and then trim them straight before connecting
@jordankai574
@jordankai574 3 жыл бұрын
What is your level of qualification? Wanted to know as an aspiring electrician.
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
I’ve got a provisional licence
@xxDADDYDAYCARExx
@xxDADDYDAYCARExx 3 жыл бұрын
Hahah and he has a yellow belt 😅😅😅
@kgfgfg1
@kgfgfg1 3 жыл бұрын
Suddenly so speachless? Did you lost your Voice for a while?
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
Yeah
@farley1992
@farley1992 3 жыл бұрын
that vde screwdriver is cool as F **K
@davidshields1240
@davidshields1240 3 жыл бұрын
Shouldn't cut RCBO neutral leads as it would void the warranty
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
Nope I rang fusebox technical
@stuarth540
@stuarth540 3 жыл бұрын
Where is the socks
@Jaymo_the_monkey
@Jaymo_the_monkey 3 жыл бұрын
Like the spacers, so much more aesthetically pleasing.
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
Helps with heat and also gives the next guy a chance to put his rcbo in without having to shuffle things around. As my personal preference is to have the highest loads nearer the main switch.
@acelectricalsecurity
@acelectricalsecurity 3 жыл бұрын
They are better than a load of unused breakers, that is really annoying when people do that.
@Cjrelectrical
@Cjrelectrical 3 жыл бұрын
Yeah especially when it’s not labeled and the client turns them all on.
@Easydread
@Easydread 3 жыл бұрын
I do like that screwdriver. I will be googling for one, i presume its a torque type. Shame cats got your tougue. Video is never right without speach
SPD INSTALLATION IN A CONSUMER UNIT - HOW TO and THE BASICS
11:46
LEARN ELECTRICS
Рет қаралды 95 М.
Gli occhiali da sole non mi hanno coperto! 😎
00:13
Senza Limiti
Рет қаралды 24 МЛН
小丑和白天使的比试。#天使 #小丑 #超人不会飞
00:51
超人不会飞
Рет қаралды 33 МЛН
这三姐弟太会藏了!#小丑#天使#路飞#家庭#搞笑
00:24
家庭搞笑日记
Рет қаралды 118 МЛН
Surge Protection Devices - Part 1
24:01
John Ward
Рет қаралды 214 М.
The BG Consumer Unit Update: What's Changed?
9:51
eFIXX
Рет қаралды 27 М.
Teaching Apprentice How to Change a Consumer Unit - Electrician Life
20:17
Artisan Electrics
Рет қаралды 116 М.
Surge Protection Devices - Part 2
20:06
John Ward
Рет қаралды 94 М.
Made a rookie error. We all make mistakes..... don’t we?
23:19
CJR ELECTRICAL
Рет қаралды 170 М.
Gli occhiali da sole non mi hanno coperto! 😎
00:13
Senza Limiti
Рет қаралды 24 МЛН