BIGGEST DIY Mistakes Adding a New Socket

  Рет қаралды 445,563

The Diligent DIYer

The Diligent DIYer

Күн бұрын

Пікірлер: 1 000
@mrfarts5176
@mrfarts5176 6 ай бұрын
Wow... fantastic explanation. I have a PhD in electrical engineering, and this guy just hit you all with a hotdog in the bum!!!!
@TheDiligentDIYer1759
@TheDiligentDIYer1759 6 ай бұрын
Very kind! Thanks for watching!
@craigomalley112
@craigomalley112 7 ай бұрын
If you're not an electrician and are planning to add any socket, or light switch. Listen to this firstly!!!! It will give you the confidence to add the electrical circuit and be certain you're doing it correctly. The advice he gives is absolutely correctly pitched AND ■(surprisingly)■ is even backed up with mathematical proof. Well done video poster!!!
@TheDiligentDIYer1759
@TheDiligentDIYer1759 7 ай бұрын
Very kind of you to say, thank you!
@capnskiddies
@capnskiddies 7 ай бұрын
I would have almost no confidence in my ability to identify the paths of ring circuits in my home. It was built in 1976, and rewired by a gobshite, at least partially, at some point in the early 2000's. I'm fairly certain I've extended the end of a radial to two double sockets in the living room, it's just for lamp lighting and phone chargers.
@capnskiddies
@capnskiddies 7 ай бұрын
I would have almost no confidence in my ability to identify the paths of ring circuits in my home. It was built in 1976, and rewired by a gobshite, at least partially, at some point in the early 2000's. I'm fairly certain I've extended the end of a radial to two double sockets in the living room, it's just for lamp lighting and phone chargers.
@paguliukas
@paguliukas 7 ай бұрын
Most gadgets now low consumption so to reach 20amps is hard plus u ad one socket not 3 or 5 😅😮 on the ring. But i agree very good explaniation i learned a lot. But if u have a litle brain u know kinda what hes saying
@shumble69
@shumble69 7 ай бұрын
As an electrician of 44 years and approved NICEIC contractor, you are pretty spot on with this video, but would remind anyone watching that the provision of a new circuit from CCU would require to be Part P notified and an installation certificate issued. But still one of the more accurate diy videos I’ve seen. 👍
@TheDiligentDIYer1759
@TheDiligentDIYer1759 7 ай бұрын
Thanks for watching!
@CriticalEducation4SD
@CriticalEducation4SD Жыл бұрын
Very effective and clear explanation here. Genuine depth of knowledge illustrated by ability to provide analytical and critical commentary on regs…Is what I’d say if this was a university assessment submission! 😅 But seriously, it’s this level of understanding our subjects, to which we should all aspire. Kudus!
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thank you, I’m no expert, just an over enthusiastic diyer
@Czechbound
@Czechbound Жыл бұрын
Even for a civilian like me I was able to follow it.
@adamhardy8690
@adamhardy8690 9 ай бұрын
Kudos
@quirkygreece
@quirkygreece 9 ай бұрын
Excellent video. I’ve been in the construction industry for over 50 years and this is the clearest explanation of domestic circuitry that I have ever heard, thank you.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 9 ай бұрын
Very kind of you to say so, thanks for watching!
@WorldSoundSystem
@WorldSoundSystem Жыл бұрын
I knew most of that, but I've never come across safe-plates before. Such a simple idea.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thanks for watching! Safe plates are great for plumbing too
@MrUtube1978
@MrUtube1978 10 күн бұрын
Hit that subscribed button purely for this video! 👏🏻 I'm a DIYer and done electrics in the past before getting a friend to sign it off, I knew the basics but you've cemented my knowledge! Thanks
@TheDiligentDIYer1759
@TheDiligentDIYer1759 10 күн бұрын
Welcome aboard!
@TheHateSpeechChannel
@TheHateSpeechChannel 4 сағат бұрын
When I can't sleep I play this video. Does the treat in seconds.. #monotonemuch
@stevegray5709
@stevegray5709 Жыл бұрын
Excellent video young man. Clear and concise. Also made me feel good about all the electrical extensions and other work I did in my 70's house back in the 80's (they really didn't cater for a future power hungry world). It would appear I did it all correctly. House is still here along with me!!
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thank you, very appreciated! Glad you enjoyed it
@johnburns4017
@johnburns4017 7 ай бұрын
@@democracyforall What are you on about?
@gman7692
@gman7692 Жыл бұрын
Two 13A appliances into a double socket is a bad idea - most are only tested at 20A across both. Washing machines & tumble dryers are a favourite for cooked double sockets.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Yep absolutely agree, washing machine and tumble driers need singles. Thanks for watching!
@craigs6892
@craigs6892 Жыл бұрын
Unless actually take note on the appliance. Meile washer 2200 watt, Grundig dryer ( heat pump) 900 watt . 13 amps both ? Safe or not ?
@gman7692
@gman7692 Жыл бұрын
@@craigs6892 That's 13.5A combined, so well under the 20A probable rating of a double socket, therefore safe.
@craigs6892
@craigs6892 Жыл бұрын
@@gman7692 thanks, I'll leave mine plugged in then. Ain't messing with sockets as cant be arsed attempting, I know not permitting anyway ( dont like changing a car battery never mind with 240v stuff ) . House safe but one day get a rewire done .
@matthewcollis-long5233
@matthewcollis-long5233 Жыл бұрын
IMO there is an often overlooked part in the regulations which states that, when designing circuits any known load (so washing machine,tumble dryer, dishwasher, panel heater, water heater etc) should be on its own circuit. Whilst this inevitably increases the size of the consumer unit it removes the need for all socket outlet circuits to be designed for 32A. A 16 or 20A radial socket circuit per floor in an average house with a 32A radial socket circuit for the kitchen and each fixed appliance on its own circuit is the way to go. Rings are an anachronism.
@AlainsIsland
@AlainsIsland 6 ай бұрын
Here in Malta we used to use ring cables and i always wondered how exactly they save less cable. Really informative thank you
@TheDiligentDIYer1759
@TheDiligentDIYer1759 6 ай бұрын
Interesting, thanks for watching!
@oakwoodgroup294
@oakwoodgroup294 15 күн бұрын
Great video really helpful as a home owner to understand the basics of how the electrics are actually run. Keep up the great work.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 15 күн бұрын
Thanks, will do!
@woodysmodellingdiary
@woodysmodellingdiary Жыл бұрын
Thank you for demystifying the issue of adding sockets. Your explanation was very clear and once again a very beneficial few minutes that sees me a little more knowledgeable and less likely to put me and others in danger!
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thanks for watching!
@alanpowell24
@alanpowell24 Жыл бұрын
Maybe you should employ an electrician?!
@Baggiolyful
@Baggiolyful Жыл бұрын
Great topic. I’m an electrician myself. I agree ring circuits are no longer needed. Most equipment in homes nowadays would happily run on 2.5 radial circuits. 60 years ago 2.5 radial circuits might not have been the perfect solution with alot more resistive loads drawing more current but nowadays everything is much more efficient.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thanks for watching! Absolutely agreed, outside of anything that has a heating element, most appliances draw little current these days
@zaxmaxlax
@zaxmaxlax 10 ай бұрын
They were never needed or used elsewhere, I didnt even know they existed until I started watching UK electricians videos. I can see the point in WW2 era britain but if you saving copper wouldnt you also save power? I can understand it in an industrial setting powering multiple machines but a 1940's home? People didn't even have refrigerators let alone washing machines and electric heaters.
@craigbeesley9601
@craigbeesley9601 9 ай бұрын
What's the difference in a spur off of a socket versus a radial circuit though, surely the same principal? And you're saying radial is fine, so why is only 1 socket allowed off a spur?
@Baggiolyful
@Baggiolyful 9 ай бұрын
​@@craigbeesley9601 I think you mean what's the difference between spurring off a ring circuit and spurring of a radial circuit ? is that your question
@craigbeesley9601
@craigbeesley9601 9 ай бұрын
@Baggiolyful no. A radial is just single wire not looped, to 4 or 5 sockets. A spur is just single wire to another socket, what difference is there in then carrying that on and making effectively another radial?
@tomsmith3045
@tomsmith3045 6 ай бұрын
I've never heard an explanation for ring circuits before! The war makes perfect sense. Thank you! Never legal in the US. Ring configurations were used in some communications systems, though, and with the same issue. Without a failure detect mechanism, you wouldn't know you lost your redundancy.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 6 ай бұрын
Thanks for watching!
@johnburns4017
@johnburns4017 7 ай бұрын
Ring circuits have been widespread in the UK for 75 years. They have been found to be *very safe.* The British G Type fuse-in-plug was to protect appliance flexes, however became an _enabler_ to use final ring circuits. The final ring circuit is ingenious in its simplicity. When used with the British G Type plug the ring is a busbar run around the house with distributed fuses at each appliance. There are many *advantages* to rings: ▪️ Cheapness, as smaller easier to install wires can be used; ▪️ A large number of sockets can be off one cheap to install ring; ▪️ Having the same number of sockets using radials would mean multiple radials and multiple extra breakers at the main panel. Far more cable, expense, labour and hassle; ▪️ The 32A breaker and 13A fuse in the plug ensures safety; ▪️ Portable plug-in appliances on a ring cannot exceed approx 3kW. Some plug-in ovens are on rings; ▪️ Rings usually have a 32A breaker at the main panel - can be a lower value; ▪️ Using push-fit *maintenance free* Wago type connectors to connect up the ring adds safety, as not being screwed connections they do not work loose. The ring's current does not run through the socket terminals (this applies to radials); ▪️ The British plugs enable rings having a _max_ 13A fuse in them - can be as low as a 1A fuse in the plug to suit the appliance and flex/cable. Small flex and appliance? Then a smaller fuse; ▪️ Rings in the UK are limited by square metres of floor space, with no limit to the number of sockets on the ring. 100 square metres of floor space with 2.5mm cable for a 32 amp final ring. The cable can be 4mm, which is advisable in an unbalanced ring drawing high current loads; ▪️Less voltage drop on long cable lengths as voltage comes from two ways; ▪️Two ways for the earth wire back to the main panel, increasing safety levels. Radials are also used in the UK. Rings are not mandatory, but used because they have proved to be generally trouble free and safe. They can be installed using *rule-of-thumb.* These days a ring will be on an RCD, RCBO or AFDD - these now are becoming DP, so safer again. AFDDs are now mandatory in some socket installations and _recommended_ in all installations. AFDDs raise the safety level. If an office wants more socket outlets for extra desk computers. It is a simple matter of extending the existing ring with the extra sockets as the current draw is low. Cheap and easy. If radials are used many radial circuits would be needed, which may mean an extra consumer unit, breakers, wire etc, then far more labour. Some *disadvantages* are: ▪️ Rings are more difficult to fault find. But electricians have no problem once the ring is fully understood. The ring can be split at a socket then tested as two radials; ▪️ Another is that if a number of high current drawing appliances are on one side of the ring, say nearer to the main panel, most of the current draw may be down one cable leg of the ring with the cable rated below the main 32A breaker. An unbalanced ring. 2.5mm cable is rated at 27A max. Although tests have proven the cables do not exceed their current capacity in the vast majority of cases, just an imbalance in distribution of the two cables from the main panel (consumer unit). *Good circuit design will prevent this, negating this* *_disadvantage._* Balanced rings can be installed by daisy chaining to _alternative_ socket outlets on the ring. That is the first appliance will draw from one side of the ring, the second socket will draw from the other side, and so on round-robin. Or use 4mm cable to the point where heavy current drawing appliances are, then 2.5mm for the rest, if it is that troubling for some. Using 4mm cable on one side of a ring and 2.5mm on the other, is still cheaper than a bunch of radial circuits. Overall one ring is superior to a bunch of radials needing their own breakers at the main panel. They are simpler, cheaper, being proven to be safe and worked well over the past 75 years. Using the new AFDDs on rings, which are _recommended_ and mandatory on some installations, gives a *far higher* safety level. You will have to give a very convincing argument against rings. I have not heard of one yet.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 7 ай бұрын
Thank you for such an in depth and well thought out comment!
@johnburns4017
@johnburns4017 7 ай бұрын
@@TheDiligentDIYer1759 A 4mm final ring circuit on an AFDD with Wago connections taking the rings load in the backboxes, and 2.5mm flex to the socket terminals is near bombproof.
@chrisholt2474
@chrisholt2474 Жыл бұрын
Great explanation, I will watch this film a few time to make sure I understand the content. Much appreciated, thank you, regards, Chris.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Awesome, thank you!
@FurFoxAche
@FurFoxAche Жыл бұрын
His voice keeps rising like he’s asking a question all the time. Very irritating.
@FurFoxAche
@FurFoxAche Жыл бұрын
It’s only 3 mins in and his rising intonation is too much. I can’t listen to any more.
@getyerspn
@getyerspn Жыл бұрын
Sparky here .. strangely a lot of homes here (Ipswich Suffolk) built 1945-1952 ish have 4mm radials for they're sockets .. I've always thought this strange for the 'after the war period'... you'd think that'd be smack in the saving metal period.... Anyway It's nightmare if you try to fit anything other than MK sockets as a lot of cheap sockets have small cable clamps that just won't take 2 4mm conductors...as for the safe zones .. kitchen fitters I'm looking at you ...the amount of diagonal cables ..or times I find sockets/ cooker switches in the combustion zone is uncountable.....nice video for the homeowners dude ..keep it up.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thanks for watching! Compliments from a professional always appreciated! Were the homes you mentioned wired with aluminium cables?
@garypautard1069
@garypautard1069 Жыл бұрын
Yes as a electrician I completely agree about kitchen fitters, in my experience I have spent hours correcting their wiring. And yes I understand about 4mm cables and MK sockets. In response to Dill-Diyer next question below. during my apprenticeship in the 60s there was a copper shortage and we substituted ring circuit cable with aluminium cable . (plumbers had to use stainless steel pipe). The shortage did not last long though.
@Bananaskin1
@Bananaskin1 Жыл бұрын
Great video, my favourite expression when I don't understand something is 'explain it to me like I'm a 2 year old'. You achieved that in spades, thanks.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thank you haha!
@marksfreeyoutube6159
@marksfreeyoutube6159 6 ай бұрын
Clear and concise , just in a 100yr old house, great heads up on potential problems, a little knowledge when discussing with electrician really helpful with my understanding
@TheDiligentDIYer1759
@TheDiligentDIYer1759 6 ай бұрын
Glad it was helpful! Thanks for watching!
@colinelliott5629
@colinelliott5629 Жыл бұрын
The explanation for the ring main system given to me many years ago was that it was used in warships for additional resilience, and then adopted after a methodical review of the wiring for homes. Before that, the radial system was used, with 3 sizes of plug and socket for different ratings. He was a physicist who had served in the navy during the war.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
That’s very interesting, and sounds plausible, thanks for sharing! Thanks for watching!
@colinelliott5629
@colinelliott5629 Жыл бұрын
@@TheDiligentDIYer1759 My curiosity was aroused, so I've just read about the introduction of BS 1363 in 1947. A number of benefits were foreseen, including economy of materials and labour. An expected 30% saving in wiring of ring over radial was indeed one of the reasons, and this was reaffirmed in 1994, despite the enormous changes.
@bobsmith3291
@bobsmith3291 Жыл бұрын
Admiral John radial and mr Gary Ring
@foogod4237
@foogod4237 10 ай бұрын
@@colinelliott5629 What everybody seems to miss about that, though, is that when they were doing those analyses they were not looking at the type of radial circuits we use nowadays. They were actually comparing _shared_ ring circuits to _dedicated_ radial circuits. An awful lot of pre-war electrical wiring had a _single radial running from the box to each appliance._ One circuit had one outlet, and that's it. So if you wanted to wire up five outlets, you were actually running _five radials_ to do it. It was really horribly wasteful. So _of course_ ring circuits would save copper over that way of doing things, because _just about anything_ would save copper over that way of doing things. Exactly the same savings could be claimed for _shared radial circuits_ like we all actually use nowadays, if they'd even bothered to consider them at the time. In fact, shared radial circuits _make better use of copper_ than ring circuits do. As was explained in the video, if you just break a ring into two radials, each with its own breaker, you could actually handle up to 40 amps instead of the 32 amps allowed for a ring (and do it more safely), so the ring configuration is actually _wasting 8 amps of current-carrying capacity_ in the wires, for no real benefit. (I can certainly buy the idea of doing this sort of thing on warships for redundancy, but for buildings it just makes no sense, and never really did.)
@johnburns4017
@johnburns4017 7 ай бұрын
Yes, they came from ships for resilience. They were introduced in the UK in late 1950s when they saw the fuse in the plug enabled rings to be fitted. My mothers house was built in 1954 with the 13A G Type sockets/plugs but with radials. Final rings were not a way to save copper after WW2, although it did help of course. Ring are ingenuous in their simplicity.
@mb-3faze
@mb-3faze Жыл бұрын
It's worth noting that a 32A breaker, for example, doesn't just trip at 32 amps. They have very well defined over-current to time characteristics. This means that the breaker will not trigger until 10 seconds at three times the rated current. Even at double the rated current the breaker could take 100 seconds to hit its thermal trigger.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thanks for the info!
@sylvester4207
@sylvester4207 Жыл бұрын
There are still electromagnetic breakers? they trip within like 100ms
@chris746568462
@chris746568462 Жыл бұрын
@@sylvester4207 Breakers contain both magnetic and thermal trips.
@HeronsHoard
@HeronsHoard Жыл бұрын
@@sylvester4207 also the magnetic trip component is for short circuit current, which needs to be able to trip high current as quickly as possible. Whereas thermal trip is to protect against overload and can take time depending on the type of breaker
@jameshansing5396
@jameshansing5396 Жыл бұрын
this entire section is why people shouldn't do 'electrics.....
@ShowcaseCreative
@ShowcaseCreative 29 күн бұрын
You just prevented me from making a potentially dangerous mistake in my loft. Thank you!
@TheDiligentDIYer1759
@TheDiligentDIYer1759 29 күн бұрын
Glad to hear it! Thanks for watching!
@stevecreighton3352
@stevecreighton3352 11 ай бұрын
Great advice and well presented. If in doubt about a ring main then replace MCB with 20A which is a good precaution in any event as high power is not usual except for kitchens with many appliances in addition to oven and hobs ( separate 6mm T&E ).
@TheDiligentDIYer1759
@TheDiligentDIYer1759 11 ай бұрын
Thank you! And thanks for watching!
@johannbraunstein1190
@johannbraunstein1190 Жыл бұрын
I am an electrician and I can prove that ring mains should be banned. If one is supposed to test without dismantling a circuit how can one test a ring main. On the standard test one has to reassemble the circuit once the test is complete which means the test one has just done is null and void because there is no proof that one assembled the tested circuit correctly.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Great point!! Thanks for watching
@patrickcannell2258
@patrickcannell2258 4 ай бұрын
Where I stay, plug circuit is now only 20A. Ring mains are discouraged for the exact reason you mentioned. I hate them. In HV networks, they are common, but very well protected. Any break is picked up. LV, a no go now.
@malcolmmaclean9380
@malcolmmaclean9380 4 ай бұрын
I have a friend who lives in Belgium but his street gets 3 phase to each house and I am sure he said they had to have radial not ring but IIRC they were cabled in 4mm
@deang5622
@deang5622 9 күн бұрын
That is not a justification for banning the use of ring mains. There are other far better sound reasons for banning them.
@henrietn
@henrietn 8 күн бұрын
​@@malcolmmaclean9380 correct. Not everyone gets 3 phase here though, only when requested on neeer buildings. Older houses still have a lot of 3x230v or 3x400v. As far as I know, ring circuits have never been used in Belgium.
@canisferus
@canisferus Жыл бұрын
I am an electrician and your explanation is brilliant. The only thing I would add is that you are allowed to have up to 3 circuit per MCB and that mean you can keep broken ring without adding new MCB as long as you downgrade it to let's say 16 amp. But this shenanigans should be checked by electrician as no dyiers know how to check for Ze and Zs which are crucial for safety in electrical installation.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thanks for the info, and thanks for watching, very appreciated!
@Farweasel
@Farweasel Жыл бұрын
CHECK for Ze & Zs My good man - I'm not entirely sure what Ze & Zs *are* 🙄
@gctelectrical5555
@gctelectrical5555 Жыл бұрын
Ze Zs R1R2 RCD trip times, Insulation resistance testing. All should be done when altering existing circuits as the Minor Works Certificate asks for these details, this is non notifiable works.
@uksuperrascal
@uksuperrascal Жыл бұрын
@@gctelectrical5555 I still have my 1000V hand powered Insulation resistance testing mega meter - a bit of history.
@IW-tb8wr
@IW-tb8wr Жыл бұрын
If space is an issue in the consumer unit, then perhaps this would be a compromise - However Regulation 314.4 (BS7671) comes into play - each final circuit SHALL be connected to a separate way in a distribution board.
@squee222
@squee222 Жыл бұрын
I'm a canadian and I just find this very interesting. Definitely prefer our code to yours :) Good video. Thanks
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thanks for watching!!
@martinhypnosmith3416
@martinhypnosmith3416 7 ай бұрын
Great information and reassuring, always thinking of myself as a competent DIYer I'm pleased to find my existing understandings fit with your professional explanation.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 7 ай бұрын
Thank you! Thanks for watching!
@grahampayne
@grahampayne Жыл бұрын
Worth mentioning that most people think a twin socket outlet is made to work with 2x appliances both running at 13amps. The BS that they are made too only requires the socket to be capable of carrying 13amps in total & if you look on the back you will see they are marked as 13amp & not 2x 13amp or 26amp. MK Electric tell me their twin socket outlets have been independently tested & will run at 19amps for a short period without any damage to the socket but if you go any higher thermal damage will start to occur quite rapidly
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Yes true, often seen when people have tumble dryers and washing machines in the same socket
@TheEulerID
@TheEulerID Жыл бұрын
@@TheDiligentDIYer1759 The secret is continuously rated. The BS standard specifies that it must be possible to draw 20A from a double socket for (I seem to remember) 30 minutes without excessive increase in heating. In practice, it's pretty well indefinite. A washing machine and a tumble drier are not going to each draw 3 kW for extended periods. It's only when the heaters are operating, and both will be thermostatically controlled. Just about the only time 6 kW will be drawn from a double socket is by plugging in a couple of 3kW space heaters into large, cold room. It is very common for circuits to be run overloaded for a period. Often a cooker will, in theory, be able to draw far more power than the nominal rating of the circuit. However, MCBs are deliberately rated on a time curve (normally class B in domestic properties) and they allow for the possibility that a particular combination of grill, hobs and oven(s) might be turned on at the same time and exceed the sustained capacity of the circuit for relatively short periods. As an example, the BELLING Farmhouse 110E Electric Ceramic Range Cooker has an electrical rating of 14.5 kW. That's 63 amperes at 230V yet the manufacturer's instructions are that it can be connected to a 32A circuit. If it just happens that a particular combination means that it draws, say, 45A for 30 seconds before thermostats and so on kick in, then the MCB/RCBO won't trip due to the thermal delay (and fuses act that way naturally). It's just the same with a double socket with a couple of high powered devices. In practice, they aren't likely to be both pulling full load for a very long sustained period. Not that anybody tells the public about this.
@leslieturner8260
@leslieturner8260 Жыл бұрын
I found that very interesting but one thought on safety plates, as most builders and some do it yourself people are now using cordless impact drill drivers you can easily drive a screw through those plates without knowing. cheers Les
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thanks for watching! I’ve hit one going through plasterboard with a plasterboard screw, with no issues. But i don’t know how it would cope with a big wood screw going through floorboards first then into a joist. Maybe I’ll do a video on them at some point and test it!
@ChrisTheSparky
@ChrisTheSparky Жыл бұрын
@@TheDiligentDIYer1759 Hi there is a video out there showing a cut away section of a joist, safeplate and a floorboard and a impact driver makes light work of the safeplate going straight through it like it's not even there!
@ChrisTheSparky
@ChrisTheSparky Жыл бұрын
@@TheDiligentDIYer1759 kzbin.infozGqfrbmRGKA?feature=share
@Farweasel
@Farweasel Жыл бұрын
People are going to suppose I have some sort of fetish or franchise selling *metal detectors* ... BUT ........... You're right, unless you set an impact driver to the lowest torque (maybe to avoid crushing plasterboard or whatever) yeah, there's every chance it would be through before it registered in your mind you'd hit metal.
@redf7209
@redf7209 Жыл бұрын
@@Farweasel I wouldnt rely on metal detectors. They dont always seem to pick up
@fgfgdfgfgf
@fgfgdfgfgf 16 күн бұрын
I've gone through all this mistake thinking. I'm smart enough not to do them though and at least educate myself through videos. So no harm done yet. Huge thanks
@TheDiligentDIYer1759
@TheDiligentDIYer1759 15 күн бұрын
Thanks for watching!
@rob5944
@rob5944 5 ай бұрын
Learning about the history of typical installations was very interesting. Only yesterday another electrician mentioned the UK as having a weird system of wiring, now I know why!
@TheDiligentDIYer1759
@TheDiligentDIYer1759 5 ай бұрын
Thanks for watching!
@Greebstreebling
@Greebstreebling Жыл бұрын
Brilliant well informed information for diy folks. Thanks very much for this. :)
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Glad it was helpful!
@David-bl1bt
@David-bl1bt Жыл бұрын
A very concise & informative video 👍
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Glad you think so!
@johnriggs4929
@johnriggs4929 Жыл бұрын
A few years ago, I went to a house to re-site a fitted wardrobe from one room to another. On pulling out the drawer unit, I came across a double socket box with both sides of the ring exposed - the socket had been removed to allow the drawer unit to fitback to the wall. No insulation tape; no strip connectors - nothing, just the exposed line, nuetral and earth hanging there. The ring was effectively broken, and had any of those conductors touched, any electrician would have had an impossible job, tracking down the fault. And all for the want of a trip to the nearest DIY store... and this was a 'proffesional' fitted furniture installer.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
That’s terrible! Thanks for watching!
@peterdavey2767
@peterdavey2767 Жыл бұрын
You may have answered a number of issues I have with a number of sockets not working as well, when charging drill battery doesn't charge on some sockets, noticed Fuse Spur, now I understand what this box is WOW
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thanks for watching!
@TPV07
@TPV07 Жыл бұрын
Interesting, here in Hungary we usually use 1.5 for general sockets (phones chargers, hoover etc) with a 13A mcb, and about 5-10sockets per radial circuits/ 2.5 in kitchens mostly 16A mcb, radial/ hob, washing machine, water heater, towel dryer, oven, all separate circuits. Never seen a ring circuit being used over here
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thanks for sharing!
@johnburns4017
@johnburns4017 7 ай бұрын
Because you do not have the fuse in plug.
@alltherestofit8109
@alltherestofit8109 Жыл бұрын
Very useful and well explained, thanks!
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thank you for watching!!
@peterdavey2767
@peterdavey2767 Жыл бұрын
Just what I was looking for, I tend to investigate before I add an addition socket, in my garage Thanks
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thanks for watching!
@rosssabah
@rosssabah 6 ай бұрын
Absolutely the best video / explanation covering virtually every aspect - brilliant learning tool, exactly what I needed, in easy to understand DIY language. Thank you so much.
@mrfarts5176
@mrfarts5176 6 ай бұрын
He is a genius and just hit you right in the bum with a hotdog!
@TheDiligentDIYer1759
@TheDiligentDIYer1759 6 ай бұрын
Glad it was helpful! Thanks for watching!
@andycarr4718
@andycarr4718 Жыл бұрын
Great video, keep them coming
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thanks Andy!
@saidkhan7155
@saidkhan7155 Жыл бұрын
Excellent video. Thanks.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thank you for watching!!
@verboeq
@verboeq 6 ай бұрын
The risk of overload when adding a spur really only applies to ring circuits on a circuit breaker too big for the individual cable, and its good to see the UK slowly catching up but obviously still having to deal with legacy installations.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 6 ай бұрын
Thanks for watching!
@roybatty2030
@roybatty2030 11 ай бұрын
Great video, thanks. I liked the tip of inserting a fused switch into a lengthy radial circuit to cap the overall current.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 11 ай бұрын
Thanks for watching!!
@adam6759
@adam6759 Жыл бұрын
Great video. Got a theoretical question however with regards to unfused spurs off a ring main. If using 4mm which has a rating of 37A clipped direct, from the ring main via a socket or terminal block, why can’t you spur more than one? Using a FCU of 13A protects the 2.5mm you would typically use, but the 32A MCB of the ring main would protect the 4mm spurs of multiple sockets no? Curious to others thoughts really…
@IW-tb8wr
@IW-tb8wr Жыл бұрын
Regulation 433.1.204 - BS7671 shows the permitted options for a ring circuit. Your theory is right with 4.0mm it would be able to cope with the load. However, potentially if your connection is at a 1/4 point on the ring circuit then four heaters are plugged into multiple sockets on your 4.0mm spur you could introduce a large load on the 1st leg which leads to an unbalanced load. This will mean potentially 32A is being drawn on the 1st leg (electricity is lazy, it will use the shortest path). By only having one spur to one socket or FCU limits the load to 26A. Same applies to an FCU serving multiple sockets the load is limited to 13A. Balancing a ring circuit should be carried out in say a Kitchen where potential heavy loads are . Although ring circuits are dying a death as are split load consumer units. The preference is going to radial circuits due to the potential faults with rings.
@adam6759
@adam6759 Жыл бұрын
Thanks. Yes, but in theory could I not have 4 heaters plugged into the first double socket and double socket spur off the ring in the house, the ring then continuing on for another 14 sockets day? Therefore it will introduce the same conditions as above? Hope this makes sense. Fully agree with your comments too, radial is the way forward especially with high integrity earthing.
@IW-tb8wr
@IW-tb8wr Жыл бұрын
@@adam6759 ​@Adam your right you could do that- all the load could be at one end of the ring circuit. 433.1.204 is just a way to reduce the chance a big load as you mentioned+ adding to that section with the 4.0mm radial which would add even more. Which is why the 4.0mm is not permitted. Here is a puzzler - you can't install a radial circuit with 2.5mm from a 32a 60898 to serve one double socket. Max load would be 26A. But you can spur off a 60898 32A to a double socket if it's added to a ring circuit. Questions to the IET
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thanks for watching!
@elliotwilliams7421
@elliotwilliams7421 Жыл бұрын
​@@IW-tb8wr is there a max distance or sqm for spurring off a ring with a 2.5mm?
@Wiltshire-observer
@Wiltshire-observer Жыл бұрын
Good basic explanation of domestic wiring. Newer houses tend to have enough sockets now, so far less likely that you would need to add more or interfere with what has been installed. However, older homes, particularly 50’s/‘60’s/70’s were barely provided for in today’s energy thirsty world. So that’s where the risks start when DIYers get involved. Many are fairly competent to add small modifications, but from my experience non-competent ones are the real risk. Sockets changed with new “USB” integral chargers is the latest risk, because those who don’t really have the necessary knowledge or good working practice can leave the terminals loose or incorrectly wired. My current home had a nightmare of half finished, wrongly completed wiring work, some of it live to the touch if you put your fingers in the wrong place. As they used to say “a little knowledge is a very dangerous thing”…
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thanks for watching!
@crcomments8509
@crcomments8509 Жыл бұрын
Those new sockets with integral USB chargers are a risk in their own right, never mind the installation.
@johnburns4017
@johnburns4017 7 ай бұрын
The worst electrical work I have seen has been done by people charging for it - general handymen, general builders, etc. I have seen some excellent DIY work for sure. Some do their research well.
@a.karley4672
@a.karley4672 7 ай бұрын
@@crcomments8509 How so? As I understand it, they're effectively triple sockets (or socket-count+!) with the additional socket driving the AC-2-DC converter. I'd see them as more threatening to the USB device (fail to putting mains into USB) than threatening to the premises overall. A couple of years ago I was talking to a Youth Hostel warden (i.e. commercial & residential work) where all the double-sockets (about 120) had been replaced with double+2*USB. I asked about the failure rate, and in a year, he'd not had one complaint of either a USB not giving charge, or a device being fried by the USB. Your assertion would imply the failure rate is higher.
@ChrisMahtal
@ChrisMahtal 3 ай бұрын
This saved me a lot of time, thank you!
@TheDiligentDIYer1759
@TheDiligentDIYer1759 3 ай бұрын
Glad it helped! Thanks for watching!
@johnburns4017
@johnburns4017 7 ай бұрын
A friend a few years back bought a one bedroom flat in London, costing a fortune of course. He was stuck for money renovating the place. He focused on the bathroom and kitchen to spend. I told him he could cuts costs on the electrical system. I explained. ... Have *two* circuits with a very small and cheap Consumer Unit box. One circuit serving a 4mm ring and one 1.00mm lighting. Heating and hot water was via a gas combi. I said Induction hobs are now available with 13A plugs. Ovens now have integrated microwaves (saving worktop space) being 3kW maximum (13A plugs). He was to have a dishwasher and washing washing. So, the ring to have: ▪ The induction hob (3kW) and oven (3kW) off 13A fused spur isolation switches in adjacent cupboards. ▪ Dishwasher (2.2kW) and washing machine (2.5kW) off 13A sockets in adjacent cupboards. ▪ The ring fed four heavyish current drawing appliances plus a toaster via the sockets. He used an IKEA kettle on the hob, so no need for an electric kettle taking up worktop space. The rest on the ring was TV, computer, combi and phone charging. If The 4mm cable was cut for any reason the AFDD 32A breaker would protect the two cable legs and also if there was any imbalance on the ring. The ring was a distributed busbar. The likelihood that all four appliances would ever be on full power at the same time was extremely slim (diversity). He bought a reel of 4mm cable on a good deal as well. I suggested at least an RCBO, but ideally an AFDD on the ring with an RCBO on lighting would be far better. He went for the AFDD costing about £55 over the RCBO at the time. Works a treat. Very safe, as *all* the flat is given AFDD protection apart from the LED lighting, which can have an AFDD in the future with a simple swap in and swap out. Never had any problems. It never costed a fortune - saving quite a lot of money. Look at the Continental main boards in one and two bedroom flats - huge and expensive full of radial circuits and breakers - typical in French installations is _three_ RDCs in a small flat. It looks like what you may have in a small school. Unnecessary.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 7 ай бұрын
Thanks for watching!
@ryanmicro
@ryanmicro 6 ай бұрын
Right, we certainly don't have that rule in Australia. Our circuit breaker has to protect the cable so cant be more than essentially 20amps on a 2.5mm² circuit
@TheDiligentDIYer1759
@TheDiligentDIYer1759 6 ай бұрын
Interesting, thanks for watching!
@olli1068
@olli1068 6 ай бұрын
I have never seen or heard of ring installations before (living in Germany). Always interesting to see what is regarded "normal" elswhere.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 6 ай бұрын
Thanks for watching!
@rkpatel100
@rkpatel100 Жыл бұрын
Working on some electrics now and this has helped, nice clear video! thank you!
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Glad it helped!
@HeartOfGermany
@HeartOfGermany 6 ай бұрын
I got a very simple solution for the ring: Just fuse both sides. Fuse is only in parallel, if the ring is connected. If it is not in parallel, it is only rated at half the amperage - which actually is still resulting in the proper rating of cable and fuse. Easy as that.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 6 ай бұрын
Thanks for watching!
@Jan_Seidel
@Jan_Seidel Жыл бұрын
In Germany 1.5 mm² solid wires are used. And the wires are placed radial or serial in the wall close to the ceiling. The sockets are split of from the ceiling in a serial manner. So it is a completely different wiring style. and 16 amps breakers are used
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thanks for watching!
@johnburns4017
@johnburns4017 7 ай бұрын
I do the 1st fix using Wago type of connectors inside the socket/FCU backboxes, connecting up a ring (or a radial), and even connecting the earth terminal of a metal backbox. The backboxes are effectively doubled up as junction boxes. The ring circuit is tested after the 1st fix. *Any wiring problems are identified before finishing trades turn up.* Putting it right afterwards may be big problems. Then the plasterers and painters come in doing their work. The Wagos are left in place in the backboxes. Then on the 2nd fix, on a bench the sockets and FCUs are prepared, by screwing into all the socket's tail's _flexible_ 2.5mm cable, including an insulated earth wire, about 100mm long with a ferrule onto the flexible wire into sockets screwed terminal connection. The flexible tails are put into the Wagos at the back of the back boxes. The socket easily pushes back in being on flex tails. Then test again. The *speed,* and *ease,* of installation is much *quicker.* And much *safer* as the ring itself does not have screw connections that can work loose. I have found many terminal screws on the back of sockets that worked loose over time - expansion-contraction, vibration from people walking on wooden floors, plugs being rammed in and out constantly, etc. That is why screwed terminal are *maintenance terminals.* Wago screwless are *maintenance free.* Wago also apply the correct torque to the wire, which is maintained over time as well. Having the full current of a ring circuit flowing through the terminal at the rear of sockets is a potential fire situation, with maybe arcing, also adding higher resistances to the ring, which may cause one leg of the ring to take most of the load, etc. That is where Wago types of connectors, in the scenario I just outlined, take the ring's load, not the _screwed terminals_ on the rear of the sockets. It is *much safer.* The sockets are only spurs off the ring, taking only current when an appliance is drawing current. Go back to a ring circuit after 10, 15, 20 years, then test it. Then go back to one which has the ring running though *maintenance free* Wago types. The integrity of the Wago connection ring will be upheld. Much safer. Having Wago types of connections on the rear of sockets, as in Germany, adds another level of safety, in eliminating another screw terminal potential failure/fire risk.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 7 ай бұрын
Thanks for watching!
@Han_80
@Han_80 2 ай бұрын
Explained everything so clearly. Subscribed and will check out your other vids. Great work!
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Ай бұрын
Awesome, thank you!
@richarddunn504
@richarddunn504 Жыл бұрын
One of the best explanations I’ve seen👍 surely plugging a 4 gang plug extension on a double spur has a risk of overload also?
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thank you! A 4 gang extension lead will have a 13A fuse in, so won’t cause you any problems
@dave07drummer
@dave07drummer 10 ай бұрын
good info, also its always worth adding up the current that devices use and plug things in sensibly, on the plus side most things use alot less current these days.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 10 ай бұрын
Yes absolutely! Thanks for watching!
@brianjonesg8aso403
@brianjonesg8aso403 Жыл бұрын
Thanks for the info, especially the safe plates which I have never seen before. I know there are none of these anywhere in my house, at the moment!
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thanks for watching!
@jamesw6698
@jamesw6698 6 ай бұрын
I'm always uneasy running a spur from a ring main with 2.5mm cable. I try to run my spurs using 4mm cable, as this gives me confidence that the spur is able to achieve the same rating as the ring. In theory, using 4mm should allow you to run two sockets on the spur as the cable is sufficiently rated, but this isn't allowed for in the regs, but using 4mm gives peace of mind.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 6 ай бұрын
Thanks for watching!
@Rx4Lyfe
@Rx4Lyfe 8 ай бұрын
Ring circuits are extremelly rare in my country..not even sure were legal in the first place...most likely error in previous sparkies electrical work. I had one by default where a doorway in a wall between kitchen and laundry had been deleted in the past & I was called to upgrade lighting in laundry. The light switch feeds on either side of old door jam were joined together as one for laundry circuit lights but they were in fact 2 separate fed circuits from the board on their own fuses. Took some headscratching to figure out why pulling each light fuse separate 1 by 1 not isolate the lights even went to isolate singley 1 by 1 every other fuse in board.. but turn off main switch only way to isolate..learning new stuff every day me.🙂
@TheDiligentDIYer1759
@TheDiligentDIYer1759 8 ай бұрын
Interesting to hear! Thanks for sharing and thanks for watching!
@Arltratlo
@Arltratlo Ай бұрын
its the exact way we do it in Germany.... because we dont have ring wiring... works fine with our 16A fuses! for over 100 years!
@TheDiligentDIYer1759
@TheDiligentDIYer1759 29 күн бұрын
Interesting, thanks for watching!
@stuartibbotson7179
@stuartibbotson7179 6 ай бұрын
thank you for the info and i was going to spur off a socket .... you can go under a floor thanks
@TheDiligentDIYer1759
@TheDiligentDIYer1759 6 ай бұрын
Thanks for watching!
@websurfer1585
@websurfer1585 11 ай бұрын
This was very informative, i have learned a few things i didn't give a thought about before thanks.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 11 ай бұрын
Thank you for watching! Really appreciated!
@roberthuntley1090
@roberthuntley1090 Жыл бұрын
I seem to remember (about 12 months ago?) that the restriction on loads connected to the lighting circuit had been watered down a bit in an update to the wiring Regs. Something like changing from a complete ban to "a suitable low load"? A KZbin from John Ward (Flameport electrics) mentioned it. In my case, I needed to supply a 1 watt TV aerial distributor in the loft so have fed a 13 amp socket via a 1 amp fuse in a FCU from the lighting circuit (to me, that satisfies the spirit of the rules).
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
I’ll take a look, thank you!
@chrissmith2114
@chrissmith2114 10 ай бұрын
As stated in video If taking a spur off a ring it is good practice to fit a fused spur box ( the clue is in the name ) .... the fuses in UK plugs are also great as the fuses are there to protect the wiring, not the device. There are not many portable devices with plugs that can draw 13 amps, a kettle and a heater spring to mind. Good advice in this video...
@TheDiligentDIYer1759
@TheDiligentDIYer1759 10 ай бұрын
Thanks for watching!!
@Asgardsteve1
@Asgardsteve1 Жыл бұрын
From personal experience I rarely come across ring circuits now, though I do still find sockets wired in with 1.5mm Cable instead of 2.5mm
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Yeah i think rings are becoming old hat now. Thanks for watching!
@andyc9619
@andyc9619 6 ай бұрын
The reason you see it is that it is permitted under the regulations, as long as it's a spur protected by a FCU. 2.5mm cable is always required on the ring circuit as it needs the extra load capacity in case of a breakage or loose connection (resulting in 2 paths on the ring reducing to 1, which theoretically doubles the load on the existing cabling), but on a spur with a 13 amp FCU 1.5mm cable (rated at 16-16.5 amps) is acceptable as it doesn't exceed the load requirements.
@Ocean-blue
@Ocean-blue Ай бұрын
Subscribed. Fantastic content clearly delivered. Brilliant.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Ай бұрын
Much appreciated!
@lucapuzzoli8363
@lucapuzzoli8363 Жыл бұрын
Thanks buddy . I'm a new learner loved the video. I didn't know about the safety plates. Cool
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Glad to help!
@RobinHow
@RobinHow Жыл бұрын
Great video - really clear, well illustrated and not overly wordy. Thank you.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Glad you enjoyed it! Thanks for watching!
@LabRat6619
@LabRat6619 Жыл бұрын
Electrical installation in domestic premises can be a very boring subject, glad you made it fun.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thanks haha, me and my monotone commentary
@johnburns4017
@johnburns4017 7 ай бұрын
Many clearly do not understand what a final ring circuit is and how it came about. The ultimate design is to have a radial to _each socket outlet_ on its own fuse at the Consumer Unit - the optimum solution of course. One fuse at the Consumer Unit for each socket. This means you will need a _gigantic_ consumer unit and lots of fuses/breakers (one for each socket) in the consumer unit, and an amazing amount of cable. 🎊🎈 *BINGO* 🎊🎈 *A final ring circuit gives this by distributing the consumer unit around the house via a ring cable,* having a fuse on each socket outlet. The ring cable is a fused *busbar.* This saves the vast expense of a plethora of radial cables back to the main panel and also a plethora of fuses at a _gigantic_ consumer unit. Simple, ingenious and highly effective.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 7 ай бұрын
Thanks for watching!
@PmBoyle
@PmBoyle Жыл бұрын
Very helpful for rewiring the garage.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Glad it was helpful!
@jameshansing5396
@jameshansing5396 Жыл бұрын
shudders!!!!!!
@terryhollis4132
@terryhollis4132 Жыл бұрын
You have a great talent for this. Perfect explanation. Thank you.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
You're very welcome! Thank you
@Nick-pr5gw
@Nick-pr5gw Жыл бұрын
Thanks nice well put together video. Happy that I meet all of your comments. Except “safe plates”. Never heard of them? Never seen them, which the plumber and the electrician that did put house had used them. They look like a very good idea. Are they a new thing?
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Not sure how new they are, but definitely recommend using them. Thanks for watching!
@Ngozika-ye9nq
@Ngozika-ye9nq Жыл бұрын
Excellent video. Thank you so much for being clear and concise. No faffing about.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thank you, very appreciated!
@philhermetic
@philhermetic 6 ай бұрын
Ring circuits were introduced in 1947, and had nothing whatever to do with copper saving. The original cable used for ring circuits was 7/029 which was rated to carry more current than 2.5mm solid conductor, which was introduced because it is cheaper to make. Most of the uk housing stock was rewired in the sixties and seventies, when you could have any number of sockets on rings, and any number on spurs as long as there were not more spur sockets than ring sockets and the whole ring did not serve an area of more than 100 sq mtr. The only time i have ever seen a break in a ring is where a socket has been installed in a damp wall and has corroded , and this is because i was trained ( at a technical college) to twist together the conductors before putting them into the socket, and then tighten the screw till the brass squeaked. Fitted like this broken rings caused by loose cables simply do not occur. Todays training insists that the cables are NOT twisted together in order to make separation for testing easier. Safety sacrificed for the sake of convenience! In a radial circuit current only flows one way and is cumulative, in a ring the actual proportion of current imbalance in the legs is tiny. The rewiring done in my day reduced electrical house fires to the lowest level they have ever been, today they are on the rise again, with consumer unit fires ( something that never existed during my career) becoming scarily common! Something is wrong, and it is not the design of ring circuits, it is the pisspoor design of the mcb termination and the pisspoor training of “technicians” If i had failed to twist wires together properly during my training I would have failed my first year practical exam, which meant you got one retake and then the sack!! Today everybody gets a pass. And the emphasis is on covering your backside with regulation compliance rather than producing a safe installation.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 6 ай бұрын
Thanks for watching!
@jameslawrie3082
@jameslawrie3082 10 ай бұрын
Very clearly and simply explained. 👍🏻
@TheDiligentDIYer1759
@TheDiligentDIYer1759 10 ай бұрын
Thank you! Thanks for watching!
@attainconsult
@attainconsult 10 ай бұрын
best explanation of this I have seen
@TheDiligentDIYer1759
@TheDiligentDIYer1759 10 ай бұрын
Thank you, very appreciated! Thanks for watching!
@Woodkin007
@Woodkin007 7 ай бұрын
As an electrician I can tell you that if its not in a kitchen, any other rooms will be fine. And if youre putting in electric radiators then run dedicated circuits.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 7 ай бұрын
The problem is you don’t know what people will plug in
@Czechbound
@Czechbound Жыл бұрын
*EUROPE* I live in Prague. Here they have sockets right over the bathroom sink ! So things are different. They have 2-pin sockets with no apparent fuse in the plugs. I guess that is inherently more dangerous ? When I came here I bought loads of 3-to-2 pin adapters and so all my UK bought electrical counter top things ( toaster, kettle etc. ) are still UK fused plugs.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Sockets over the sink is crazy! Thanks for watching!
@neilduran3586
@neilduran3586 Жыл бұрын
Thanks, this is very interesting and very informative!
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Glad it was helpful!
@raywalsh5414
@raywalsh5414 Жыл бұрын
I learnt quite a few things from that, thanks !
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thank you, really appreciate that!
@David-lb4te
@David-lb4te 6 ай бұрын
I find that with modern appliances, there is a general reduction in average load. To get to 21A on a circuit takes quite a lot of appliances.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 6 ай бұрын
Yes you are right. Thanks for watching!
@adamwatson7817
@adamwatson7817 4 ай бұрын
Can you please do a video on live neutral reverse etc. Many thanks!
@TheDiligentDIYer1759
@TheDiligentDIYer1759 4 ай бұрын
I’ll put it on the list, thanks for watching Adam!
@hartpa
@hartpa 7 ай бұрын
All very useful thank you.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 7 ай бұрын
Glad it was helpful!
@TheMasterbennett
@TheMasterbennett 7 ай бұрын
Most sockets will blow past 13amps that's why you can add one socket to a ring without a fuse spur. Also you can spur of lighting as long as it is labelled as 3 or 5 amps max
@TheDiligentDIYer1759
@TheDiligentDIYer1759 7 ай бұрын
Thanks for watching!
@shoaibnadeem
@shoaibnadeem Жыл бұрын
Thee best video on KZbin!
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Very kind, thank you!
@G1ZQCArtwork
@G1ZQCArtwork 11 ай бұрын
I was asked to fault find for a local firm, as finding faults is long and time wasting. I specialise in fault finding, so was the right candidate. I went to a Bungalow, split the ring and proceeded to hunt. I found the crushed burned cable under the doorstep of the conservatory, which was spurred off a socket in the adjacent kitchen. The builder of this conservatory had fitted SIX double sockets on the spur,,, SIX.! The crushed cable was Black and sooty from the arching.... Another fault I found was in a Caravan, the "maintenance" had removed a faulty smoke alarm and replaced it with a battery operated version. No longer needing the mains supply, this "maintenance" person just shoved the bare ended wires up in the roof cavity surrounded by damp insulation, which caused nuisance tripping when it was wet with condensation. It still happens people, no matter how stiff the regulations might be.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 11 ай бұрын
Those are both bad faults! Thanks for sharing that!
@tomf4547
@tomf4547 Жыл бұрын
I like the idea of radial in my new garage wiring.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Yeah I think radials are best
@stevoc9930
@stevoc9930 Жыл бұрын
The unfused spur going off to feed who knows how many points, is a favourite of Kitchen Fitters who also think they're a Spark because they move a few sockets around.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Absolutely! Thanks for watching
@nooneyouknowhere6148
@nooneyouknowhere6148 8 ай бұрын
Ring circuit is crazy. In the US you can only use the size breaker which your wire is rated for. #12 wire max 20A breaker which is rated for 16A continuous duty. If your load is more than 16A for an extended period of time the breaker will trip. We only do what you call radial circuits here. You don't want power coming from two directions in case of a fault.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 8 ай бұрын
Interesting to hear, thanks for watching!
@tomorrow3582
@tomorrow3582 8 ай бұрын
Really good videos. Nice clear explanations at a digestible pace and without any bs. Subbed. Do you know of any good sources of info for learning about how many amps to put safely on a circuit, what cables and fuses to use etc? Some software or interactive website would be ideal for testing different wiring combinations etc
@TheDiligentDIYer1759
@TheDiligentDIYer1759 8 ай бұрын
Thank you, very kind of you to say so! I’m afraid I don’t have anything to recommend, sorry! Thanks for watching!
@RonJeremy-ef1es
@RonJeremy-ef1es 8 ай бұрын
Consult a properly educated and trained electrician. There are many factors to take into consideration before connecting a cable to an electricity supply.
@1globe
@1globe 7 ай бұрын
Excellent informative clip. Clear and to the point! I'm now a follower! 👏✅
@TheDiligentDIYer1759
@TheDiligentDIYer1759 7 ай бұрын
Welcome aboard! Thank you!
@stepheniedickinson8688
@stepheniedickinson8688 8 ай бұрын
Brilliant! Concise and authoratitive.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 8 ай бұрын
Thank you! Thanks for watching!
@gctelectrical5555
@gctelectrical5555 Жыл бұрын
I would say most socket circuits are reference method C so 27 amps as buried in the wall is to be considered clipped direct. Upstairs lighting circuits are likely to be method 101
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Thanks for watching!
@harmonicresonanceproject
@harmonicresonanceproject 10 ай бұрын
This was incredibly informative. Thanks!
@TheDiligentDIYer1759
@TheDiligentDIYer1759 10 ай бұрын
Glad you enjoyed it! Thanks for watching!
@ursamajor6546
@ursamajor6546 Жыл бұрын
Apart from the rising inflection at the end of every sentence - good 👍
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
My wife said the same haha. It is something I’m trying to work on. Thanks for watching!
@ursamajor6546
@ursamajor6546 Жыл бұрын
@@TheDiligentDIYer1759 Good lad! 😂 👍
@leecornwall8381
@leecornwall8381 5 ай бұрын
Excellent explanations!
@TheDiligentDIYer1759
@TheDiligentDIYer1759 5 ай бұрын
Thanks Lee! Thanks for watching!
@vman2kay
@vman2kay Жыл бұрын
The thing that confuses me about the double spur, is can't you overload the circuit anyway without one? In your diagram you had 3-4 sockets on one radial leg. Maybe I'm missing something?
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
A radial circuit is typically on a 20A breaker, whereas as a ring is usually on a 32A breaker
@vman2kay
@vman2kay Жыл бұрын
@@TheDiligentDIYer1759 Gotcha, I now realise the double spur without a fused connection would potentially damage the spur part of the cabling due to the 27A max cable rating (assuming 2.5mm2 T&E). I was basically questioning why the argument for overloading the spur wasn't being made for a radial or ring because you could plug 13A * no of sockets into the circuit, which is way more than they can support but ignored the fact that the circuits have breaker protection, but the specific section of the spur cable doesn't and can be overloaded as it's less than the usual ring breaker limit.
@harstan7333
@harstan7333 9 ай бұрын
@@TheDiligentDIYer1759 Having only 2.5 cable and a 20A breaker on a radial circuit rather limits its use with multiple sockets, surely? Wouldn't 4.0 cable and a 32A breaker be more usual, and preferable?
@tonybaker7453
@tonybaker7453 Жыл бұрын
If i do a socket radial I always use 4mm2 cable on a 32A breaker. I agree that ring final circuits carry an invisible danger is the ring is compromised. Good video though. Even my plumbing mate understood it!!!
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Жыл бұрын
Plumbers get so much grief from electricians haha. Thanks for watching!
How to Add a Socket to a Wall - Easy Step By Step Guide
18:55
The DIY Guy
Рет қаралды 152 М.
RADIAL SOCKET SPURS. How to install them correctly and safely.
10:18
LEARN ELECTRICS
Рет қаралды 71 М.
Prank vs Prank #shorts
00:28
Mr DegrEE
Рет қаралды 10 МЛН
BIGGEST DIY Mistakes Joining Cables
8:52
The Diligent DIYer
Рет қаралды 234 М.
WORST DIY ELECTRICS I'VE EVER SEEN! 🤯
22:52
Artisan Electrics
Рет қаралды 662 М.
5 Biggest DIY Mistakes Wiring a Socket
6:02
The Diligent DIYer
Рет қаралды 694 М.
10 Mistakes EVERYONE Makes When Doing DIY Electrics!💥
11:56
Artisan Electrics
Рет қаралды 167 М.
5 Mistakes Everyone Makes Changing Sockets ❌
11:44
Artisan Electrics
Рет қаралды 501 М.
U.K. Electrics SUCK! This is what we should be doing…🇫🇷
19:17
Artisan Electrics
Рет қаралды 195 М.