Thanks for this is educative. But, the generator will not turn off, it will continue running untill it's turned off manually unless it's auto starting single phase generator. It is the gen contactor that will turn off hence cut off supply to the load ..
@yakinimudala355910 ай бұрын
I agree with you. So how can this be modify this such that a generator can be turned on and off , not continuously running
@Le_vis25410 ай бұрын
@@yakinimudala3559 From my point of view, I do not suggest any modifications to the already existing wiring because I do not see anything wrong with the connections here.. It's only that he didn't mention that the generator should be started and stopped manually though the wiring is just okay..or the modification I would suggest may sound funny: assume the generator has manually operated switch on it, we can alter its wiring and use the stop/ start push buttons from the control panel now- remember this is is not automatic operation still but we shall have reduced the movement to the generator room to manually turn on/off the generator every time we experience mains power outage
@francisudeoji406 Жыл бұрын
I will really appreciate ❤
@ScoviaSinda8 ай бұрын
Thanks for teaching
@KALLEOTRANSPORTLOGISTICSLLC4 ай бұрын
Do you have a electrical circuit diagram for changeover between Solar and Generator such that Solar is the main source and would change over when batteries reach a threshold level ?
@ssdgensets Жыл бұрын
Hi sir your all video super, which software using for this diagram drawing ...
@AnilKumar-xm1yb8 ай бұрын
Wonderfully explained, but the way you moved the NCs, created some confusion. I would rather you kept the NCs in their places and moved the wiring (though the NC labels are clear). Thanks.
@benedictomnubi59348 ай бұрын
😅
@kayitamoses858010 ай бұрын
Thanks for the work, can you kindly direct me how I can add a timer and phase monitor to this circuit
@JoelynPandii10 ай бұрын
Nice explanation for single phase but please can you indicate also the contactor number
@gmbeingit6 ай бұрын
Awesome video. If I wanted to add this ATS for a home running 220v (2-110v legs) with neutral and ground, along with a generator that is running the same, how many input/output would I need on the device?
@francisudeoji406 Жыл бұрын
Please sir do ats for 1main and 2 generator Which will be 3contactors, 1 for Main 1 for first gen 1 for the 2nd gen
@jayawantbavaskar9369 Жыл бұрын
Instead of an aux contractor, u can use a duel pole relay
@Zups10 Жыл бұрын
But what about the generator neutral going back to main? Should it be not disconnected?
@muhammadismail55794 ай бұрын
Where from we can get these contactors for domestic use?
@kholofelomalatjie22066 күн бұрын
Just a stupid question. Can you use any Contactor ?
@sriarun406410 ай бұрын
Anything is possible to covert Ongrid to offgrid solar system when power shutdown
@dannydaher13662 ай бұрын
What if I am using Utility as a secondary source and generator as a primary source? which means the utility will always be on standby and hot and being used as a secondary source.
@AkhtarBhat-l9d Жыл бұрын
Hi sir
@TheElectricalGuy Жыл бұрын
Hello
@AkhtarBhat-l9d Жыл бұрын
Is this simple contactor or any other
@Zups10 Жыл бұрын
But what about the generator neutral going back to main? Should it be not disconnected?
@TheBeso199411 ай бұрын
Can we use a DPDT relay instead of the aux contactor?
@TheElectricalGuy11 ай бұрын
Yes
@TheBeso199411 ай бұрын
@@TheElectricalGuy Thanks.
@LesiSusaika5 ай бұрын
What if I use NC of Auxiliary Contact 3 Pole Normally Open Auxiliary 1NO/1NC Contactor
@lawrenceamissah847310 ай бұрын
which means the generator needs contractor with 12v DC from the battery
@雪アンアン5 ай бұрын
I dont understand the use of all these when ucan do it with one contactor
@aworldknowledgebro.54129 ай бұрын
Wrong
@naranpindoria22718 ай бұрын
yes, so many things are wrong here
@staremmitor794614 күн бұрын
🌤 sonney' .. Kalkuta, The Kalkuta wore cotton Bombay panties.. tiKa' tiKA 🌵KJV☆ AMEN UPPER CANADA