Float Switch Connection with Contactor for water tank 100 % Practical Video

  Рет қаралды 339,207

The Electrical Guy

The Electrical Guy

Күн бұрын

float switch connection with Motor starter
What is float switch
A float switch is a type of level sensor, a device used to detect the level of liquid within a tank. The switch may be used to control a pump, as an indicator, an alarm, or to control other devices.
Watch this video In Hindi
• Float Switch Connectio...
Thank You
Arun Gupta
Electricaltechnician02@gmail.com
══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
Hindi Channel @Electrical Technician
/ electricaltechnician
2nd Channel @electrical Wiring School
/ electricalwiringschool
Short Video @electrical technician Shorts
/ @electricaltechnician02
TELEGRAM :
telegram.dog/El...
FACEBOOK : @electricaltechnical
/ electricaltechnical
INSTAGRAM : @electricaltechnician02
/ electricaltechnician02
══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
My gadgets for KZbin 📺
Camera 📸 For video Recording
amzn.to/3z3W9XM
Mic 🎤 For Sound Recording
amzn.to/3kpUyaK
Tripod Stand
amzn.to/3BajZmn
Overhead Stand For Recording
amzn.to/3z1rzhm
══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
Electrical Device For your Home which you Should Have
Wi-Fi Control Smart Plug top
amzn.to/3dAZrJA
amzn.to/3hcO6Sr
Multimeter for electrician
best - amzn.to/3w7Vbry
Low Price - amzn.to/3wfF1MC
Water Level Controller
Single Tank - amzn.to/3xdcrwY
Double Tank - amzn.to/2UnvJAX
Motor Starter
2 HP Motor Starter - amzn.to/366AlhL
2 HP Motor Starter - amzn.to/3xhVtxw
Toolkit For Electrician
amzn.to/3AmK1T5
══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
Related video which you Must watch
Digital Ammeter and Voltmeter Connection
• Digital Ammeter & Volt...
DOL Starter remote Wiring
• How to Wire DOL Starte...
Tower Light Connection
• Electrical Machine Sig...
Auto Changeover Switch Connection
• Auto Change Over Switc...
MCB Vs RCCB Vs RCBO
• Difference Between MCB...
#floatswitch #connection #wiring #electrical #electricalengineering

Пікірлер: 105
@sacrajah
@sacrajah Жыл бұрын
Wow! I am loving your practical video... God bless you... You have become my favourite
@motherearth517
@motherearth517 Жыл бұрын
Very clear instructions. Thanks for the video.
@brianedwards231
@brianedwards231 Жыл бұрын
Brian Edwards I would like to know how this circuit is wired where the pump is replaced by a 220v submersible well pump that has a control box with the required starting and running capacitors. Great video. Thanks.
@julioverzo1932
@julioverzo1932 Жыл бұрын
Additional knowledge. Awesome
@muciiwamikwekwe6490
@muciiwamikwekwe6490 4 ай бұрын
It's educative but would suggest we use neutral cable to the float switch instead of live to avoid shock then live cable from MCB go direct to contractor terminal
@wajidyoutuber4555
@wajidyoutuber4555 Жыл бұрын
Nice video Information technology systems keep up continue with your video
@pobrengamatv5791
@pobrengamatv5791 Жыл бұрын
Your explanation is cristal clear. Thank you
@leopoldofernandezjr.508
@leopoldofernandezjr.508 Жыл бұрын
Thanks Tatay✌️
@ramborums
@ramborums 8 ай бұрын
Thanks for the simple clear video. Is it safe for the mains voltage to be connected to the float switch which goes into the water? Is there any possibility of leakage?
@danielteyehuago1633
@danielteyehuago1633 Жыл бұрын
This is very educative, thanks for sharing it with us...
@josephongoi2419
@josephongoi2419 17 күн бұрын
Good work
@UthmanEshaq
@UthmanEshaq 14 күн бұрын
Thank you for your explain
@balakotireddy7006
@balakotireddy7006 6 ай бұрын
I gone through few other videos but something missed in their videos. However your video very clear and neat demonstration. Thank you..
@ChrispaulAyieko-hx1zz
@ChrispaulAyieko-hx1zz Жыл бұрын
Thank you very well illustrated
@damienlandry1359
@damienlandry1359 10 ай бұрын
Thank you! Very helpful
@complexpower1396
@complexpower1396 Жыл бұрын
I have tried this system but it has a flaw. The float switch contacts do not pass the current after a while because of the sparking. So what i did was that i used a relay connection with 12 volt 5 amp dc adaptor. This reduced sparking and is working perfectly
@TheElectricalGuy
@TheElectricalGuy Жыл бұрын
Float switch current rating is low so if your motor Current rating is high then you have to use a contactor Float switch should be used to turn on and off Contactor
@potrishriram7
@potrishriram7 Жыл бұрын
I use instead of 12v 5 amp adopter, i use 12v 1 amp smps board (cost is 42 rupees).
@danielteyehuago1633
@danielteyehuago1633 Жыл бұрын
I think identifying the neutral cable should rather be using the digital multimeter to test for the continuity between two cables... Thanks
@MES6664
@MES6664 11 ай бұрын
Great job 👍
@JHANDEER
@JHANDEER Жыл бұрын
Great Really appreciated
@angelosackey9446
@angelosackey9446 11 ай бұрын
Please I will be grateful if you can make a video on how to install a ceiling fan.
@TheElectricalGuy
@TheElectricalGuy 11 ай бұрын
Watch this video kzbin.info/www/bejne/kJOYZpihorppj6s
@larrypog5050
@larrypog5050 Жыл бұрын
Thank you.. interesting
@ssennonojohnmary4406
@ssennonojohnmary4406 Жыл бұрын
Excellent.
@aadedeelectric
@aadedeelectric Жыл бұрын
Thank you for sharing
@ajibolataiwo6684
@ajibolataiwo6684 Жыл бұрын
God bless you
@techteam565
@techteam565 5 ай бұрын
It's good option for automatic motor pump control.we are also using this way.
@richardako6612
@richardako6612 Жыл бұрын
Good work sir, very very helpful
@muhammadnaeem4834
@muhammadnaeem4834 Жыл бұрын
Nice
@danielteyehuago1633
@danielteyehuago1633 Жыл бұрын
Please do you have a tutorial on how to use a single float switch to control both overhead tank and underground tank with a single motor
@TheElectricalGuy
@TheElectricalGuy Жыл бұрын
By only one float switch you can only control the single take water level
@azizahmedmuhammad4124
@azizahmedmuhammad4124 Жыл бұрын
This is what i am also looking for. Two upper and non same level water tanks with float switches and one ground water tank with a single water pump. This is a challenge now... plz somebody hepl..
@mattiasbanda3063
@mattiasbanda3063 Жыл бұрын
​@@azizahmedmuhammad4124it's possible but you will need two contactors
@zorrofox4937
@zorrofox4937 Жыл бұрын
How.... You need to know the tank level
@Le_vis254
@Le_vis254 6 ай бұрын
​@@mattiasbanda3063 There must be two float switches bro and 1 contactor is enough. No way you can use 1 float switch to control 2 different water tanks at different levels
@shansur734
@shansur734 Жыл бұрын
@samuelteerseer8034
@samuelteerseer8034 Жыл бұрын
Very interesting 👌
@techsartamil4529
@techsartamil4529 Жыл бұрын
Float switch control voltage AC230V or 12DC ?
@nandhakumar9917
@nandhakumar9917 Жыл бұрын
Very clear explanation But directly given power supply to float switch not safe
@user-ln1yb2xu4c
@user-ln1yb2xu4c Жыл бұрын
Thanks for your practical work thanks for the experience pact to me am grateful sir
@kennethmbah3353
@kennethmbah3353 Жыл бұрын
Clear explanation
@georgeburuku8868
@georgeburuku8868 Жыл бұрын
good demonstration
@user-ee1db9bc2q
@user-ee1db9bc2q 9 ай бұрын
@jr electrical school Can you tell me what changes I should make in wiring so that my motor turns off when water level is low and turns on when water level is above set low level in float switch. This is for a .5hp pressure booster pump on I’ve put on the terrace
@shakeelahmad5745
@shakeelahmad5745 Жыл бұрын
Plz explain the connections of contector with relay. N plz mention me to get notification. Thanx a lot
@krishnapala2149
@krishnapala2149 Жыл бұрын
Very Nice
@jonopaw7511
@jonopaw7511 28 күн бұрын
@TheElectricalGuy I have an underground and overhead tank, can this be done with 2 float switches?
@striker1258
@striker1258 7 ай бұрын
Good video and explanation but How does this work with safety if we were suppose to have a break in float switch and water goes in?
@stanleyo.uchendu6284
@stanleyo.uchendu6284 Жыл бұрын
Thanks for sharing.
@TheElectricalGuy
@TheElectricalGuy Жыл бұрын
Thanks for watching!
@vijaymane3334
@vijaymane3334 3 ай бұрын
Which types contactor used in this. please specification.Ampere, voltage etc.
@britishplumbing1
@britishplumbing1 4 ай бұрын
What I don't understand is both cables on float switch are basically connected to the same live wire
@venkatmanivenkatmani8460
@venkatmanivenkatmani8460 6 ай бұрын
Give neutral supply to float switch it's. Safe don't give phase supply it's not safe
@jordanarcano1978
@jordanarcano1978 Жыл бұрын
Thank you 😊
@bhonenaykhant
@bhonenaykhant Жыл бұрын
thank
@candyvlogs15
@candyvlogs15 Жыл бұрын
Why can't we break nutral at the place of phase by float switch
@TheElectricalGuy
@TheElectricalGuy Жыл бұрын
You can control neutral also
@hetasarvaiya6443
@hetasarvaiya6443 5 ай бұрын
Electric power switch ji
@ManiSampathHemachandran
@ManiSampathHemachandran Жыл бұрын
Hello Is dry run protection involved of no water in well or bore then motor not run even tank is empty????
@umeshgkk6619
@umeshgkk6619 Жыл бұрын
Plz menstaion description of contractor
@Richardpjohn47
@Richardpjohn47 2 ай бұрын
can you metion value of contactotr
@ANTHONYJR20
@ANTHONYJR20 3 ай бұрын
is it the same set up with a 200v pump?
@jkj1459
@jkj1459 Жыл бұрын
NEED TO FLOAT SWITCHES FOR PROPER FUNCTIONING .
@danielteyehuago1633
@danielteyehuago1633 Жыл бұрын
Please how can you know whether the current rating is high for the float switch... Thanks
@TheElectricalGuy
@TheElectricalGuy Жыл бұрын
If the current rating is High you have to use Contactor
@143AmmuMama
@143AmmuMama Жыл бұрын
What types of contactor use
@danielteyehuago1633
@danielteyehuago1633 Жыл бұрын
@@TheElectricalGuy it's just a general question I want to know... I have not used a float switch before...
@danielteyehuago1633
@danielteyehuago1633 Жыл бұрын
@@143AmmuMama it's just a general question I want to know... I have not used a float switch before...
@TheElectricalGuy
@TheElectricalGuy Жыл бұрын
Check the current of the motor by using clamp meter or ammeter And if your motor running current is more than 8 Amp please use a Contactor to connect the float Switch
@user-so3xk1lm4j
@user-so3xk1lm4j Жыл бұрын
Спасибо
@ANTHONYJR20
@ANTHONYJR20 3 ай бұрын
what if i have a 220v pump? what size MCB (1 ppole or two) and what sixe magnectic conector do i need?
@harifire1153
@harifire1153 2 ай бұрын
How we can be peaceful when we know the hole 220v is in water tank what if the power goes on water
@chitithoti
@chitithoti Жыл бұрын
Can this be installed under and overhead tank
@sachinsheoran6806
@sachinsheoran6806 5 ай бұрын
Wiring mistake,,again check during underground tank
@vijiemirates5526
@vijiemirates5526 Жыл бұрын
220 voltage in floater switch 💧💧💧
@tayyabultahir
@tayyabultahir Жыл бұрын
No dear, only neutral line is connected to float switch
@harveyalfaro2925
@harveyalfaro2925 10 ай бұрын
what contactor did you use? NC or NO?
@bernardchangtyseng7202
@bernardchangtyseng7202 9 ай бұрын
NO?
@user-nn4wz6ro2t
@user-nn4wz6ro2t Жыл бұрын
🇧🇩🇧🇩🇧🇩🇧🇩🇧🇩
@saravanaselvaraj4113
@saravanaselvaraj4113 7 ай бұрын
Bro how to connect timer switch in water tank
@carmelomalubag2656
@carmelomalubag2656 2 ай бұрын
Dangerous.. 220volts for float switch
@awaazmatroko5972
@awaazmatroko5972 Жыл бұрын
CNC contactor brand is not available locally, pls add link for purchase of the same thanks
@mukundanpp7018
@mukundanpp7018 6 ай бұрын
Wire selection for the float is wrong. When the float is in hanging position the motor should start.
@koko-by3se
@koko-by3se 11 ай бұрын
Can I use any watts of float to 5 water pump
@TheElectricalGuy
@TheElectricalGuy 11 ай бұрын
Can used in Control Circuit
@mukundanpp7018
@mukundanpp7018 6 ай бұрын
How much rs for contactor?
@rudymunoz7720
@rudymunoz7720 Ай бұрын
Ohhhh stank you come again😅
@vijiemirates5526
@vijiemirates5526 Жыл бұрын
There is a big mistake in this wiring here 🤦‍♂️🤦‍♂️⛔⛔⛔⛔
@anvarboncafedileep553
@anvarboncafedileep553 11 ай бұрын
Use time delay
@bambi_listens
@bambi_listens 7 ай бұрын
what is it?
@shanazzafar9411
@shanazzafar9411 6 ай бұрын
Give your correct advice then.
@kalidossv3949
@kalidossv3949 5 ай бұрын
MCB In out connection reverse
@shvelkumar4094
@shvelkumar4094 Жыл бұрын
Hindi me
@TheElectricalGuy
@TheElectricalGuy Жыл бұрын
Hindi video kzbin.info/www/bejne/r6O9hnSMj5uqnM0
@abilashkgtcr
@abilashkgtcr Жыл бұрын
Dear............ neutral wire to be connected to float switch & phase connect to Contactor's active terminal ..........avoid phase wire connect to float switch refer this vedio kzbin.info/www/bejne/fZebmGCqf9KXnas kzbin.info/www/bejne/hHTGaolpr5hloLs
@vijiemirates5526
@vijiemirates5526 Жыл бұрын
it's not professional
@vijiemirates5526
@vijiemirates5526 Жыл бұрын
it's not up to english standards ⛔⛔⛔⛔⛔⛔
@vijiemirates5526
@vijiemirates5526 Жыл бұрын
⛔⛔⛔⛔it's very dangerous⛔⛔⛔⛔
@srb2996
@srb2996 Жыл бұрын
40 years before came this technology...
@jayachakravarthy8626
@jayachakravarthy8626 5 ай бұрын
You English speaking very worst tension
@moreclick2481
@moreclick2481 5 ай бұрын
am having a problem to determine which contactor rating A to use for the residential pump motor what is your advice plz
@user-ic1mp8rr8j
@user-ic1mp8rr8j 11 ай бұрын
Very good
@danielteyehuago1633
@danielteyehuago1633 Жыл бұрын
Wow! I am loving your practical video... God bless you... You have become my favourite
@jom.r3593
@jom.r3593 Жыл бұрын
Nice
@filmonYaci
@filmonYaci Жыл бұрын
Thank you for sharing
float switch wiring practical video
4:57
Jr Electric School
Рет қаралды 1,6 МЛН
Алексей Щербаков разнес ВДВшников
00:47
Magic trick 🪄😁
00:13
Andrey Grechka
Рет қаралды 43 МЛН
HOW TO INSTALL FLOAT SWITCH FOR WATER PUMP
3:38
Genesis Engineering
Рет қаралды 275 М.
CONEXION DE DOS FLOTADORES
2:14
Simón Franco
Рет қаралды 51 М.
Installing a Floating Switch in Your Water Tank for Automatic Level Control
5:05
Learn Pass Earn Professional
Рет қаралды 2,6 МЛН
inside float switch|electreca
7:40
ELECTRECA
Рет қаралды 77 М.
DIY Float Switch Pump Wiring (Easy Step-By-Step Guide)
11:02
ELECTRECA
Рет қаралды 109 М.
What is Contactor? | All About Contactors | Wiring Diagram
9:18
Electrical lectures
Рет қаралды 300 М.
Алексей Щербаков разнес ВДВшников
00:47