Was very helpful but pls can you make videos in details practical will be more helpful Thanks...
@dex42103 жыл бұрын
I need some help getting this cooler to run
@joshuam11463 жыл бұрын
whats going on with it?
@djaffartablat55627 жыл бұрын
pourquoi mon thermoking affiche la tension batterie grimpante de 12a25v puis le compresseur s'arrête et affiche code 25 alors que sur l'alternateur il y'a 14,2v avec mesure de multimètre ?
@naushadali953 жыл бұрын
Please make video on tk 500 on alarm code 17
@pablitoburciaga73514 жыл бұрын
Tk md200 alarm 35 Already check my pressures, bypass hp switch, unplug my fuel solenoid & fuel pump Still alarm 35, replace the relay board and also I have a spare micro What else to check ?
@joshuam11464 жыл бұрын
Pablito Burciaga does the engine crack? Or does the alarm come up right away and the control starts blinking?
@pablitoburciaga73514 жыл бұрын
@@joshuam1146 No it doesn't crack the buzzer stay on then it blinks alarm 35 Notice not getting power supply to fuel pump when the buzzer it on . I used my power probe and get the fuel pump running
@joshuam11464 жыл бұрын
Pablito Burciaga hi! Check all your fuses. There’s a plug on the engine side that goes down to the fuel pump. Disconnect it and retest, just to rule out that section of wiring from the fuel pump to that plug. Otherwise its looking like there’s a electrical short somewhere in the wiring. You’re gonna ha e to follow all the wiring, I can email you a wiring diagram in case you need one
@pablitoburciaga73514 жыл бұрын
Thank man for your help found out the unit had to 2 problem one was the fuel solenoid and the other one was the starter
@amineminos52538 жыл бұрын
Mode cycle sentry not displayed on sceen
@joshuam11468 жыл бұрын
Amine Minos if it's not displayed cycle through the control until you hit cycls-yes or no. If you want the unit to cycle on and off change to yes and press enter. If you want continuous change to no and press enter
@pedromoreno32148 жыл бұрын
tengo un problema no puedo bajar ni subir temperatura en un equipo themoking.solo baja a 34f y sube hasta 36f...que hago para que baje mas y suba
@joshuam11468 жыл бұрын
Pedro Moreno se tiene que meter a super guarded menu. STH es la temperatura máxima que se puede set. Y STL es la temperatura baja que se puede set. Cambie esas temperaturas a las que quiera el cliente...
@23cetona4 жыл бұрын
My reefer shuts off before it reaches to set points and display blinks. Code 33 check engine rpm What can I do I
@joshuam11464 жыл бұрын
Reaper48 _YT check your engine speeds, either the engine is running too slow in low speed and high speed OR its running too fast in high speed. Most recommended speeds on tk md/kd/ are low-1625. High-2425 both +-25 but that depends on your unit. another problem may be on your rpm sensor, check the wiring connections on the sensor. Send me the model of unit you have...
@23cetona4 жыл бұрын
Thank u How can I fix it?
@joshuam11464 жыл бұрын
Reaper48 _YT all depends what the problem is
@jimmygujjar83504 жыл бұрын
Alarm O2 fault active in my refer .kindly send me video to in activate ..Thermo king sbiii max
@joshuam11464 жыл бұрын
jimmy gujjar if you can’t erase that alarm most likely you’ll have to replace your evaporator coil sensor. Beware because it may be a graded sensor and you have to go in super guarded access to change the grade.
@antonionajerabadillo74126 жыл бұрын
Buenas noches tengo un problemita con el Thermo se me activa muy seguido el defroster ya le cambié el sensor que va oculto con sintaxis es el no graduado y sigue la falla
@joshuam11464 жыл бұрын
Antonio najera badillo revisé el defrost air switch
@10btiger7 жыл бұрын
Hey what is code 148 on Thermo king
@joshuam11467 жыл бұрын
Yasha Bezginov hi! Alarm 148 is auto switch electric to diesel disabled...
@jeromecampbell36998 жыл бұрын
hey bro i have a problem with a code number 74 can u help me out
@joshuam11468 жыл бұрын
Jerome Campbell hey sorry I took forever to get to you. Alarm 74. You have to get into guarded access menu, bring down the service hour meter back down to 0. While you are in guarded access, alarm 74 should display, when it does erase it. It will not appear until the unit reaches the hour limit again.
@joseeugenio9727 жыл бұрын
alarm 61 como limpar da tela
@joshuam11467 жыл бұрын
José eugenio da silva cuando la alarma 61 este en la pantalla, empuja el botón = y se va a borrar. Esa alarma es de batería baja, asegúrese de que estén cargadas las baterías...
@j.p.89617 жыл бұрын
saludos puedes subir un vídeo en español indicando como resetear las alarmas y cual es la función de cada uno de los botones d este thermo king? gracias de antemano trabajo con un camión que utiliza un thermo king de estos y cada cierto tiempo no prende y lo debo llevar al técnico el le toca los controles y hace que funcione de nuevo sin hacer mas nada y pierdo tiempo en ir al técnico.