Why using 4-20mA in industry

  Рет қаралды 110,047

Thundertronics

Thundertronics

Күн бұрын

Пікірлер
@youtuuba
@youtuuba 6 жыл бұрын
Good video, but it still fails to explain a few important things: - In series circuits, current is constant, meaning that current is the exact same at any point in that series circuit. - Current is NOT less affected by magnetic fields than is voltage. However, if extra current is magnetically induced at one or more points in a series circuit, that same current will also flow everywhere else in the circuit. Because of this, the transmitter is 'aware' of the extra unwanted current and can thus instantly adjust the loop current to compensate. The same applies to changes in the resistance of the series circuit. This compensation would not be possible if the process signal were sent as a voltage. - The action of the transmitter is key to the success of the current loop. It can instantly adjust its series resistance as required to regulate the loop current to the desired value. It also monitors the loop current so that it can instantly compensate for errors and outside influencing factors. - Some current loops DO use 0-20mA. One of the advantages of using 4mA as the minimum normal value is, as the video states, to allow detection of open circuit and/or loop power supply failure. Another big reason is that always having at least the 4mA quiescent current in the loop circuit, is that this provides a small power source to operate the transmitter, as long as the transmitter is designed to never require more than 4mA. Without this quiescent current, there would need to be an additional power supply to operate the transmitter circuitry; this scenario is called "4 wire". When the transmitter is designed to operate on only the quiescent 4mA, then no additional power supply is required, and this is called "2 wire".
@alexlee2663
@alexlee2663 6 жыл бұрын
Yes, 2-wire transducer(sensor) save costs in practical industrial use. there is our 2-wire transducer:g-sensor.net/signal-conditioner/ac_current_transducer//2019/0110/380.html
@alexlee2663
@alexlee2663 6 жыл бұрын
for a long distance signal transmission, voltage has a drop,but current does not , thats why normally use current to transmit electric signals. As far as a voltage/current transducer(sensor) is concerned, the output signal adopts 4-20mA that's because 4-20mA is a safe signal,esp,in a coal mine,or explosive-proof sites, the spark energy caused by 4-20mA current is not enought to cause explosion. www.g-sensor.net
@Thundertronics
@Thundertronics 3 жыл бұрын
thanks for your feedback
@clems6989
@clems6989 2 жыл бұрын
As a rule if thumb. I will use 0-10V within a cabinet. And always use current [4-20ma] for all field wiring or if it leaves the cabinet.
@Thundertronics
@Thundertronics 2 жыл бұрын
yes for field always current-based stuff.
@mohamedklileche7382
@mohamedklileche7382 4 жыл бұрын
Outstanding video explanation, informative, and straight to the point . Thank you for sharing
@Thundertronics
@Thundertronics 4 жыл бұрын
thanks!
@ahmedaliabdelrazik87
@ahmedaliabdelrazik87 6 жыл бұрын
Question, Why we don't have use 1V as a minimum voltage, hence we can detect both minimum and open circuit, like 0 and 4 mA
@Thundertronics
@Thundertronics 6 жыл бұрын
It is better to use currents not voltages according to what I explained. using 4mA as a minimum instead of something like 1ma is according to my thought due to the fact that 1ma is almost noise level and you cannot differ between if it is noise or a signal, while 4ma is obviously not noise. thanks
@Dilidjent
@Dilidjent 6 жыл бұрын
Really good video. thanks!
@lucygao2476
@lucygao2476 4 жыл бұрын
Really nice explanation! Very clear~
@Thundertronics
@Thundertronics 4 жыл бұрын
Glad it was helpful!
@suradrabee5526
@suradrabee5526 3 жыл бұрын
كيف ممكن اعرف الحساسات اذا ما عليها مواصفات
@Thundertronics
@Thundertronics 3 жыл бұрын
ممكن تذكر لي اسم واحد أو موديله حتى أدلك. لكن لو فيه هارت بتقدر ببساطة عن طريق جهاز الهارت
@suradrabee5526
@suradrabee5526 3 жыл бұрын
@@Thundertronics انا سالت السؤال بناءا ع انه من الاسئلة العامة الممكن تنسال في مقابلات العمل هندسة ميكاترونيكس/ قسم الصيانة حسب ما سمعت من مهندسين . اذا ممكن تفيدني باي مصدر معلومات عن الموضوع بكون مشكورة
@janmalesela2510
@janmalesela2510 6 жыл бұрын
good, you dnt offer online training
@MM-vi9kh
@MM-vi9kh 5 жыл бұрын
ما هو Noise؟
@Thundertronics
@Thundertronics 3 жыл бұрын
النويز وشوشة غير مرغوب فيها في الإشارة
@MM-vi9kh
@MM-vi9kh 3 жыл бұрын
@@Thundertronics ما سببها؟ وكيف نحل مشكلة وجودها؟
@Thundertronics
@Thundertronics 3 жыл бұрын
@@MM-vi9kh النويز موجود في العالم لأن عالمنا ليس ديجيتال. تحلها حسب كل مجال
@rohitdatar3988
@rohitdatar3988 7 жыл бұрын
Good work👍
@MM-vi9kh
@MM-vi9kh 5 жыл бұрын
ليش ما تشرح العربي؟
@Thundertronics
@Thundertronics 3 жыл бұрын
لأن قناتي إنجليزية من البداية
@musharafkakar1591
@musharafkakar1591 7 жыл бұрын
Arabic version is
@asam982
@asam982 7 жыл бұрын
Thanks
@vijaykavali2708
@vijaykavali2708 6 жыл бұрын
Video is so nice but we want this type of all videos in Telugu launguage
@muhammadadnanahmed4995
@muhammadadnanahmed4995 6 жыл бұрын
v nice
@tiziocaio4334
@tiziocaio4334 7 жыл бұрын
4 20 I see what you did there
@NawtieBoy96
@NawtieBoy96 6 жыл бұрын
what? :)
@chrissourp6807
@chrissourp6807 5 жыл бұрын
Yup
Wiring emergency stop buttons
2:21
Thundertronics
Рет қаралды 136 М.
4-20 mA Current Loop - History, Why, Advantages, Disadvantages
14:52
Instrumentation Tools
Рет қаралды 183 М.
It works #beatbox #tiktok
00:34
BeatboxJCOP
Рет қаралды 41 МЛН
99.9% IMPOSSIBLE
00:24
STORROR
Рет қаралды 31 МЛН
黑天使被操控了#short #angel #clown
00:40
Super Beauty team
Рет қаралды 61 МЛН
fluke 789 simulate vs source 4-20ma
7:44
CADISAC
Рет қаралды 47 М.
All you need to know about 4- 20 mA Conversion :4-30 mA current loop basics
12:18
How the Clock Tells the CPU to "Move Forward"
14:22
Core Dumped
Рет қаралды 144 М.
Flawless PCB design: RF rules of thumb - Part 1
15:45
Hans Rosenberg
Рет қаралды 96 М.
Active and Passive 4-20mA - What's the Difference?
3:31
McCrometer
Рет қаралды 10 М.
DIFFERENTIAL PRESSURE TRANSMITTER 4-20MA DC 24V 2 WIRE
14:28
JSL BEJO
Рет қаралды 2,5 М.