Even Siemens can't explain like you ! Your really a good teacher ! Thank-you !!!
@hegamurl74345 жыл бұрын
Thanks😁
@usamashaikh71302 жыл бұрын
@@hegamurl7434 really you are great in explaining the concept
@BrandanG193 жыл бұрын
Got a project dropped on me at work today. Pretty new to Tia portal, this video saved me thank you!
@owinookello93582 жыл бұрын
this guy is genius i love his teaching so clear big up bro
@hegamurl74342 жыл бұрын
Thanks man!
@Manne-st9mr Жыл бұрын
@@hegamurl7434 How come u stopped making content ?
@muhannadfakhri Жыл бұрын
Woooow 🎉 🎉🎉🎉🎉 Really you are good teacher Thanks we appreciate all what you give
@hegamurl7434 Жыл бұрын
Thanks!
@mohsennekuee90393 жыл бұрын
vielen Dank für ihre Bemühungen
@sam83503 жыл бұрын
Thank you for your informative video.. Explanation was really great.. Here you have used S7-1500 and et200.. I want to know that is communication and programming same for S7-1200 and ET200SP.. Also how about working with normal ethernet (cat-6) cable..
@firasn.t.50372 ай бұрын
Very informative course, well done.
@denissorto82713 жыл бұрын
How to do a backup of a PLC which include an ET200 in the same net.? Thank you so much for share the knowledge.
@jojoon1937 Жыл бұрын
Please Make a video about s1500 encoder setting using a remote I/O rack and module
@moustaphamuhammad701320 күн бұрын
Amazing Tutorials.
@gajendram64623 жыл бұрын
Super sir ..I am always share your videos for learners
@valentino37043 жыл бұрын
Thanks. Hegamurl. That's helped me in my migration. Tumbs UP..
@ajmalgani1517 Жыл бұрын
Best video i never see before
@HIRENECTECH4 жыл бұрын
Hi, Very well described the point. I would like to know how these all devices connected to each other physically. A simple diagram is just fine for me
@lamiselhamud36243 жыл бұрын
You are the best. Thank you!!!
@hoangnamnguyen72144 жыл бұрын
You are really good teacher. An excellent tutorial.
@azayelcalderon71345 жыл бұрын
You are the best!
@YellowsWorkshopАй бұрын
Question!? I have RIO ET200sp With a DI 16x24v st DQ1 6x24vdc/0.5v st AI 2xu/i 2-/4-wire HF They all have light base All connect to power from the same power supply My unit connects but the DQ and the AI modules are blinking red lights I changed everything physically new stuff so i know the error is my program but i cant find it. Everything matches :(
@mybox61772 жыл бұрын
Thank you. Is it possible to make such circuit ring from such IM module. May be a star with switch.
@IK-qu9hw7 ай бұрын
I am using 412-5H redundancy system with et 200 sp Im module on profinet communication, but my IM module is not taking IP address what is problem?
@OnceAgain07042 жыл бұрын
thank your so much Bro.
@simonmax39015 жыл бұрын
That was excellent
@hegamurl74345 жыл бұрын
Thanks!
@banci11003 ай бұрын
hello sir! hope you safe and sound.. want to ask...🙏🙇 should the CPU to connect the ET200 is S7-1500? how about S7-1200? is it OK? thank you, Sir.. hope your day as bright as the Sun🌄
@Malavaniengineer Жыл бұрын
Thank you so much❤
@framos9991 Жыл бұрын
Thank you!
@shivam53312 жыл бұрын
Nice explanation. Thanks
@dennisrubio2375 Жыл бұрын
Master 🧨
@mateovelarde20562 жыл бұрын
Hi!! Could you explain how to transfer and read data with the instructions DPRD_DAT/ DPRW_DAT ? For array data or structs with boolean data. How to safe them in a DB. How to call each data individually and read them through from a GSD. Thank you for all :D
@saeedmns22278 ай бұрын
Is it possible to simulate ET200 and S7 CPUs in PLCSIM without and physical devices?
@bhushankulkarni12593 жыл бұрын
It's been really great experience learning Siemens feom your videos. Could you please do exactly same video on Profibus DP with some third party devixe using GSD file?
@nandarora13034 жыл бұрын
Thanks for making such an informative video. In this the i/o addresses of peripheral were automatically given by the plc on downloading. But in case we had already installed one IM and it got faulty and we have to replace it. Now, what if the plc gives some I/O addresses not according to the ones we have already used in the plc program's ladder logic? How can we directly give them addresses before downloading?
@emmanuelkoskei86964 жыл бұрын
excellent tutorials , Keep up the great work
@qhawemoyo89403 жыл бұрын
Hi, great video. With S7 1215C I know maximum number of signal modules in local rack is 8. When you connect it to ET200 SP does it mean you can add 64 more modules or the 8 is inclusive of distributed IO (i.e total for both local and distributed IO shouldn't exceed 8 signal modules)?
@kme81342 жыл бұрын
I would like to know the same thing. But I think TIA portal will answer this for us. If you can configure many IO devices (more than 8 modules) in Tia, then it should be the same in real life. No?
@Qasemzarei2 жыл бұрын
You could address maximum of 1024bytes for input and 1024 bytes for output in 1200 CPUs. That means: 1024 Analog I/O (8bytes) or 1024*8=8192 Digital I/O or a combination of those which should not exceed 1024bytes.
@tznalcn3 жыл бұрын
Hey Hega Whats could be the point of using only rmodules(upper parts) without lower parts (Inputs and Outputs) for ET200 extra modules such as for example Technology ones?
@wannabeviralstar Жыл бұрын
Hello! Great video, a quick question, if you need to change the configuration of the remote module either by adding a card or changing an analog card input from 2 wire to 4 wire, does this require a whole new hardware download or can it be done without stopping the PLC?
@AKov04923 жыл бұрын
Hello from Ukraine)
@naveenrawat4339 Жыл бұрын
Sir how report created in Tai protal wicc advance
@LearningTecx Жыл бұрын
Hi what configuration your pc or laptop, Bcoz when I installed TIA portal in laptop is get slowdown in speed. Your's is working very fast, can suggest me the configuration it will helpful for me. Thank you
@arjanvandekuilen43544 жыл бұрын
Hi do you also have tutorials of this subject but then with WLAN communication. My problem is that hardwired I have no problems with recognizing the IO-Device (Sick OLM200) but when I put them on WLAN (Anybus AWB2030) sometimes they are recognized but most of the time not.
@aeon55672 жыл бұрын
Um here's a beginner question.. Is the decentralized/peripheral IO and IO LINK MASTER the same thing
@JustIce-zv8pk5 жыл бұрын
Great video. Thank You
@Rob63c4 жыл бұрын
thanks for all the video's, can you make a video about prodiag thanks.
@GustavMinnesjord2 ай бұрын
verry nice
@Ana199782 жыл бұрын
Thanks!so useful!
@nomandanish4412 жыл бұрын
Thanks
@saeed2tube5 жыл бұрын
It can add 50 module? And why it has memory slot?
@hegamurl74345 жыл бұрын
Both good questions! The amount of modules you can connect depends on the type of the external I/O... the one I used in the video can have up to 64 Modules (including the Interface module and power modules), so it can grow very big. But different hardware would of course have other modules limits. The one I have has a mandatory memory slot, where it saves the module data... without it, it won't run. But again... different modules will have different requirements and most of them don't have a Memory Card Slot
@manutentoreelettrico6474 жыл бұрын
Thank you Sir!!
@sicilykid914 жыл бұрын
I keep getting "Error, Error in lower level devices" on all my peripherals
@hegamurl74344 жыл бұрын
You can check the error in your hardware configuration when xou are online. All components have diagnostic capability
@ectromeca86022 жыл бұрын
very nice video
@dukenuke26905 жыл бұрын
Thank you :)
@hegamurl74345 жыл бұрын
You are very welcome!
@oogalook4 жыл бұрын
Thanks so much! Question: How are your devices connected? Are both your IO device and computer plugged into the "X1" ports of your S1500? Or are all your parts connected to a router or something?
@HalfSpec4 жыл бұрын
I would say yes, that @Hegamurl could do it that way since he's only connecting a computer and the ET200. However, if you wanted to connect a second ET200, you would be out of ports on the particular S1500 he is using. In that instance you'd need a switch. Profinet is compatible with standard ethernet switches as long as the switch is 100mbit or better and full-duplex. That means you can link your computer, PLC, and three ET200s to a $20 5-port netgear switch from Amazon and everything would happily talk to each other. Of course, not all switches are built equal and you probably don't want to use a $20 netgear switch in an industrial application, but hopefully it demonstrates the point :)
@oogalook4 жыл бұрын
@@HalfSpec Thanks buddy! Good advice!
@JinsonKurianVJames5 жыл бұрын
Excellent
@lollofbb15 жыл бұрын
Thank you PLC god!
@hegamurl74345 жыл бұрын
Now, that's a title I could get used to!
@johnbiayakadiebwe71215 жыл бұрын
EXCELLENT
@ahmetmklnc1983 жыл бұрын
thanks you....
@karoliczanwojtylanu4 жыл бұрын
Can TIA Portal assign IP adress to ET200 automatically? I can not understand why have you assigned IP adress to this device twice? Coudn't you do it just once?
@nikog22434 жыл бұрын
also confusing for me. Once it's .144, the other time it's .145...
@DeKempster4 жыл бұрын
You have to set the profinet device name. IP settings are written form the plc.
@ksenijadizdar97092 жыл бұрын
I think this Hegamurl's video should help answer that question: kzbin.info/www/bejne/aKjLnH6Vn8x3hbc&ab_channel=Hegamurl
@makenzo23713 ай бұрын
👍
@michagoralczyk21403 жыл бұрын
Perfect.
@abderaawofshaibi95712 жыл бұрын
I would like to communicate with you, I want your help and we could make deal. I have projects and I need your advice. How can I get in touch with you
@mohammedrezk80724 жыл бұрын
The series of ET200 is not organized at all.
@rigelectrician224 жыл бұрын
Hi, Thanks for making these nice and clear videos Can you please make a video for below blocks, DPRD_DAT, DPDR_DAT, CNT_CTL1 How this pointer addressing works ??? P#DB100.DBX0.0 BYTE 4 What is DBX0.0 and BYTE 4, Why sometime I see BYTE 8 or some others also DBX 50.15 and etc I like to communicate with my Wago remote IO's through Profibus from CPU317-2 PN/DP. (317-2EK13-0AB0) v2.6.7 Wago I/O rack 750-333 coupler 750-637 encoder 750-455 AI 4 channel 4-20ma 750-478 2AI 0-10 vdc 750-457 4 AI. +-10V 750-430 8 DI 24v 757-600 Dummy I am just a beginner, started to make a project with siemens hardware and Wago IO's I just like to know how you change LADDR, RECORD, when I add or remove input cards .. Also ''CNT_CTL1'' for collecting data from Counter card "350-1AH03-0AE0"