I wanna share some experience. Our brother did this correctly but it's recommended to replace PVC pipe with poly because PVC will not last very long (probably 5-8 years) under direct sunlight, use flap-type check valve (spring check value will lose 15% pressure), use pipe union Use check-value (spring type) if it's installed vertically (because spring type is flexible can be installed both vertical or horizontal) or high pressure (use for water pump). Use check-value (flap type) if it's installed horizontally with low pressure (example syabas meter) because it's more durable and easy to service If use water pump, the recommended accessories are : 1. spring type check-valve 2. pressure meter 3. pressure relief valve 4. pressure control valve 5. thermal switch 6. pressure switch (usually come together with water pump) Some high value properties/industrial installation using double protection for thermal switch, pressure relief valve, pressure switch
@mohdhussainlah74485 ай бұрын
Sy sebagai juruteknik nk punya video ni.sy nk bg 5. Bintang KT abg yg buat video ni.mmg clear Dan fhm.abg ni ajar..boleh jadi cikgu bang.sy puji abg..bgus bang ilmu xkedekut..murah rezeki abg Dan sihat buat selamanya..Amin
@MrFzul78 Жыл бұрын
bagus kaedah ni saya dh guna hampir 5 tahun,cuma kekurangannya bila cek valve Tu rosak air Akan msk ke dlm tangki Dan over flow,lalu ko blur bila tukar valve pelampung tp air tanki still melimpah,Dan akhirnya ko dpt tau rupanya c.valve Tu rosak bila tgk u tube org lain bgtau kekurangan kaedah cek valve ni.
@fixfairuz1808 Жыл бұрын
Terima atas penerangan tn...
@ismailomar46013 ай бұрын
Sebaiknya guna one way valve jenis flip..jika guna jenis spring kkdang spring jem n bendasing tersangkut susah lepas..jenis flip bendasing akan mudah lepas..oneway valve jenis flip sesuai utk tangki perumahan yg kandunganya kurang dari 500 galoon..jika jenis spring air akan perlahan sebab tekanan air kurang kuat utk buka valve jenis spring..jadi akan perlahan dari asal..itu pengalaman sy membuat kerja2 pemasangan oneway valve ini..🙏 Dalam video ini kekurangan 1 lagi valve..ianya perlu dipasang pada paip utama utk elak air tangki mengalir kembali ke meter apabila air dari meter terputus bekalan..
@zolkifklimohamad77945 күн бұрын
Yang mahal (valve) jangan yang murah
@syamsull99882 жыл бұрын
Assalamualaikum wbt bang.sy ni sepatah haram tak tahu apa2 tentang paip,rumah saya ada masalah air slow di bilik mandi melalui tangki,jadi saya ulang berkali2 perkongsian abg ni utk saya faham,alhamdulillah petang tadi siap bang sy bua,3jam sy buat haha ,air laju ngam semua..terima kasih bnyk2 bang,semoga murah rezeki dan di permudahkan semua urusan...aamiin...
@fixfairuz18082 жыл бұрын
Alhamdulillah.....
@zafranbm74072 жыл бұрын
@@fixfairuz1808 boleh sy dapatkan contact number tuan
@fixfairuz18082 жыл бұрын
010 339 2020
@BJey-ui6ud2 жыл бұрын
3 jam x per.. yg penting dpt siap sblm waktu2 kritikal...hehe
@fixfairuz18082 жыл бұрын
sama2 kita belajar... byk juga idea2 dlm komen2 yg diberikan...blh baca jg....guna yg mana betol...yg komen merapu tu, abaikan jer
@khairulazman2661Ай бұрын
Pemerangan yang amat jelas..terima kasih Tuan sedia kongsi ilmu yg bermanafaat
@jxhisam Жыл бұрын
kene ada lg 1 check valve kat bypass utk elakkan air tangki return ke meter. elok guna swing valve, takde spring. lebih tahan lama
@mohdnasir4921 Жыл бұрын
Betul tuan, klau xda 1lgi check valve air dari tangki keluar ke meter. Bila air xda, air dlm tangki pun habis. Itulah pengalaman umah saya
@fixfairuz1808 Жыл бұрын
Sy lupa nk bgtau dlm video...psl tmpat sy buat ni ada frp water filter kt luar rumah slpas meter yg smmngnya air tersekat kat situ.... kebiasaannya cv sy pasang slpas meter jika rumah tiada water filter coz semua outlet akan dpt supply dr tangki jika air dr main pipe tiada termasuk sinki dapur...
@GrengggTV9 ай бұрын
Abg rumah area mana ya? Ada pernah nampak komen org kata kat meter air tu dah ada non return valve @@mohdnasir4921
@ismailomar46013 ай бұрын
Ya betul..kekurangan 1oneway valve di paip air dari meter👍..juga baik guna oneway valve jenis flip..👍🙏
@deadsmile2011 Жыл бұрын
mudah cerita brader ni sambung direct dari bekalan luar, kalau air luar xmasuk air tangki ada 👍👍
@alienling69975 ай бұрын
Sikit tak sama. Ada non return valve, pressure lebih tinggi Dari direct sambungan
@chabautv39992 ай бұрын
Saya paham maksud awak..dan kenyataan awak benar .
@azizsaaid2400 Жыл бұрын
Tkaseh bang ilmu yang bagi mula saya beli yang menggunakan elektrik bila saya lihat saperti ini ...tak payah mengunakan elektrik......tkaseh ilmu yang abng bagi saya akan cuba,.....🤲🤲🤲🤲🤲🤲🤲🤲
@fixfairuz180811 ай бұрын
sama2...alhamdullillah....kalo masih ada part yg xfaham blh tanaya yer...
@muhammadhaikalkamsani89855 ай бұрын
Penerangan abg ni sangat jelas dan mudah faham terima kasih bang
@hishamhisham72172 жыл бұрын
Perkongsian yg sangat baik. Ilmu yg sangat berguna.. trima kasih
Kalau pressure air direct laju boleh la buat mcm ni ..kalau air dari meter pun meleleh Kena pakai water pam jgk ..sy plumber area utara...mmg byk sy pakai booster pam kalau rumah 2 tingkat,3 blk air ke atas.rumah setingkat 2 blk air pun nak pakai booster pam sbb air mmg puas hati...laju....sy sendiri pun kena pakai water pam....air slow sgt kat rumah sy...apapun perkongsian terbaik....
@fixfairuz1808 Жыл бұрын
blh kongsi x dgn kitorang semua brp hp diperlukan utk rumah spt diatas...? dan Pam seeloknya dipsng sblm tangki @ slpas tangki?
@budakbaik7425 Жыл бұрын
@@fixfairuz1808 pasang pam kena selepas tangki bang. X boleh sebelum tangki, syarikat air marah nanti
@harzman1123 Жыл бұрын
@@budakbaik7425 ya.... betul... jika pasang pump lepas meter, ia aniaya pada jiran jika pressure air dari luar slow. pump kena pasang lepas tangki, maksudnya sedut dari tangki.
@harzman1123 Жыл бұрын
kaedah bypass dan one way valve ni, jika air direct pressure ok dah contohnya jika setahun air direct tak tutup2, maka tangki setahun lah bertakung, tak guna
@pakatdiysendiri Жыл бұрын
@@harzman1123 kat utara sy psg tank asing kat bawah,sbb tekanan air terlalu slow,air masuk dari ke tank baru dulu..pastu guna booster pam utk sedut air ke dlm rumah,kat tank asal sy buat bypass....tank atas tetap air akan turun jgk tuan bila kita buat bypass....kat sini sistem mcm tu ja yg terbaik....tp kos mmg tinggi la..cuma mmg terbaik la...mandi shower pun best...tp tangki flush blk air xleh pakai yg biasa..yg pakai pelampung hitam tu...sbb cepat rosak...air terlalu laju...mcm tuan ckp air kat tank akan bertakung sy xberapa jelas sbb sy buat bypass air tank pun akan guna... semalam pun sy p cek rumah custumer sy....air tank dia akan kurang bila guna bila air...boleh tahu booster pam akan jln utk topup blk ke tank atas....sekadar info dan pengalaman sy buat pemasangan water pam/booster pam....
@dollyone3714 Жыл бұрын
minit 3:17 dah nampak.. seluruh sistem tangki diganti hybrid tangki + air bekalan. bermakna jika bekalan air xde, air akan perlahan kembali.
@fixfairuz1808 Жыл бұрын
Yer betol.. cara ini hanya alternatif utk kurangkan kos....
@hartman48823 жыл бұрын
penerangan mantap gile..seronok menonton dgn dpt ilmu sekali..,,👍
@fixfairuz18082 жыл бұрын
mekasih tuan...
@abdulghanidarus15273 жыл бұрын
Dah guna bypass direct water, fungsi checkvalve tu dah jd bekalan spare. Kalau bekalan direct terputus maka tekanan dari tangki akan menolak check valve utk bekalkan air
@fixfairuz18082 жыл бұрын
abselutely yes....👍
@aleaf882 жыл бұрын
Kalau bekalan air tak terputus maksudnya air dr main sentiasa ada.. air tangki tu takkan digunakan betol ke? tp mcm mana nk bg air dlm tangki tu digunakan ya sebab kalau lama sangat dalam tangki tak bagus kan?
@yiktakata39682 жыл бұрын
@@aleaf88 air tangki tetap keluar bersama air direct main
@MrFazley2 жыл бұрын
@@yiktakata3968 xmungkin air tangki keluar bersama air direct..sebab tekanan direct kuat berbanding tangki maka air direct akan tutup checkvalve.. cuba tgk 17:10
@MrPuteraIslam Жыл бұрын
@@aleaf88 kalau dah pasang check valve mmg air tangki tak gerak selagi air main ada. Mcm saya saya akan buat satu lagi paip direct tangki buat ambil wuduk. So air tangki still gerak
@mustafazahari85902 жыл бұрын
Mantap ilmu yg saudara perturunkan kerja2 sambungan paip begitu kemas sekali
@fixfairuz18082 жыл бұрын
tima kasih ....hasil pngalaman sblm2 ni....sy guna pelbagai jenis paip jgk coz nk tgk kualiti camner... sy pn try & error jgk... insyaallah apa yg ada dlm dada sy , sy akan curah kt sini....
@jameelbasyariaziz4 ай бұрын
Assalamualaikum tuan.. terima kasih share ilmu, alhamdulillah faham apa yg tuan share.. apa yg saya faham, air dalam tangki baru akan turun bila paip utama tak ada air.. ini akan brlaku air dalam tangki tak digunakan dan boleh mengakibatkan air betakung lama dan busuk..
@abgchik58082 ай бұрын
Senang kata check valve tu letak selepas stopchock outlet dari tangki tapi sebelum pipe bypass
@montoyapablo2089Ай бұрын
saya rasa klu bikin bypass..xperlu psng checkvalve..klu tujuan nya bypass utk dptkn pressure air lebih kuat utk support air dr tgki..ke rmh. Klu psg checkvalve air tgki xakn supply kermh...Tngki tkr peranan sbgai reservd tank. sila btlkn klu silap.!
@mohdayobmohdzin75292 жыл бұрын
Terbaik bosku penebangan jelas.. Ini projek terbaru saya.. Air dirumah saya slow sangat.. Terima kaseh tuan... Inshaallah harap berjaya..
@fixfairuz18082 жыл бұрын
Alhamdulillah...hrp ilmu yg tuan belajar ni, dpt tuan kongsikan jgk dgn jiran2 & sahabat2 yg lain.....kongsikan ilmu besar pahalanya...insyaallah...
@AzlinaSamsudin-hz9go Жыл бұрын
Sy tk ada tangki..semua guna derek dari meter..air laju..tangki sper sy asing guna tong biru..dan mudah kerja2 mentenans.
@eliz40902 ай бұрын
Assalamualaikum bang. Saya ada masalah bilik air dari tangki air xkuat. Rumah saya double storey. Bilik air di tingkat atas. Macam mana nak dpt perkhidmatan dari tuan utk buat kat rumah saya. Tuan sangat jujur bagi penerangan dgn jelas dari A to Z. Semuga tuan dimurahkan rezeki. Tkasih
@fairulmohamad51296 ай бұрын
mantap penjelasan
@idrisb75158 ай бұрын
Terima kasih Tuan, boleh cuba. Selalu bila bukak 1 paip, yang lain air macam meleleh aje.
@yusuffsmile77702 күн бұрын
Terbaikk bang😮💨 faham dh
@olkap1283 Жыл бұрын
Salam tuan, saya buat by pass, bilik utama je laju air dan bilik air no 2 pelahan....lubang tangki satu utk bilik utama dan bilik air no 2......check valve satu dari main n satu dari air tangki....
@fixfairuz180811 ай бұрын
buka kepala paip bilik air no 2...mnhkin ada benda yg tersumbat
@matsem41093 ай бұрын
12:37 terima info bang, saya baru tahu spec jkr
@azaharibrahim8776 Жыл бұрын
Terimakasih Abg diatas perkongsian ilmu tersebut.moga rezeki Abg diluaskan
@andygoh13613 жыл бұрын
Air kuat kerana paip air dari meter dah bypass selepas check valve,..
@LoongFatt7 ай бұрын
Masalah bypass ini , air di tangki ada chlorine masa fresh dari sumber Tapi bila terlalu lama tinggal di dalam tangki , chlorine tu sudah tak ada, bacteria dah kulat pula Akan datang. Masa tak ada air, tak tahu air dari tangki itu selamat atau tidak. So guna cara ini , perlu clear tangki air atau rajin Cuci air dalam tempoh beberapa hari atau minggu. Atau guna booster pump terus.
@azamab Жыл бұрын
Terbaik
@amirmdsaid6843 жыл бұрын
T.ksh atas perkongsian ilmu
@fixfairuz18083 жыл бұрын
sama2 tuan....hrp bermanafaat...
@dollyone3714 Жыл бұрын
untuk tahan lama, saya spray clear coat spring check valve tu.
@fixfairuz1808 Жыл бұрын
Betol...lagi esok spray sgn paip sekali utk panjangkan hayat paip dr sinaran uv atau air hujan...
@syaifullizan40693 жыл бұрын
Baguih , terang dan jelas, tp rase bill air ade increase jgk mcm nih..... Good job 👌
@fixfairuz18082 жыл бұрын
increase xbyk sbb tekanan smmngnya dtng jg dr paip utama....
@castello4812 жыл бұрын
ya bil air akan meningkat sbb guna direct dari paip utama, mesti meter jalan laju, hehehe
@billychunboonchin3032 жыл бұрын
Guna air incoming memang la kuat... Tapi sudah kurang pasang 1 check velve kat incoming...
@fixfairuz18082 жыл бұрын
tidak juga jika incoming slow air tetap akan slow tanpa bantuan booster pump....video inihanya utk incoming yg stabil dan tekanan melebihi 1.5 bar...
@maziahputeh8993 Жыл бұрын
@@fixfairuz1808mcm mna ye nk tahu bacaan tekanan air kt rmh kita tuan? apa alat yg perlu ada bole dikongsi x? tuan dduk dekat area mana tu? klau dekat dengan sy nk mnta tolong buatkan kt rmh sy…nanti buat kira2 brapa kos brg nk buat serta upah psg….bole tuan?
@quddusyusof64742 жыл бұрын
Terima kasih diatas perkongsian ilmu..moga dapat balasan di dunia dan akhirat
@adilah66022 жыл бұрын
Respet✌️✌️. Sangat² jelas penjelasan tuan. Ini baru betul nk jd KZbin. Sy like Dan subcribe. Kalau ada iklan pn sy Tak skip iklan😀. Smoga murah rezeki Dan mnjadi KZbinr berjaya bosku✌️✌️✌️
@fixfairuz18082 жыл бұрын
Alhamdulillah..terima kasih atas doa yg baik2....⚘️
@faizalaz28112 жыл бұрын
Penerangan yang jelas….
@tighnari792 жыл бұрын
terbaik bang. terima kasih memperkenalkan check valve
@fixfairuz18082 жыл бұрын
dh buat dh ? kalo ada xfhm blh tnya yer....
@lolanwawo16252 жыл бұрын
@@fixfairuz1808 bos nak tanya... boleh ke air dari tangki turun, sekiranya air dari meter tak ada, sebap chek valve tu ada spring, air dari tangki tu kan tekanan tak kuat, ?
@panjisemarang1 Жыл бұрын
tmkasih tuan atas perkongsian yg bagus. nk tanya, paip yg menegak ke atas pd permulaan kluar service paip dr tangki tu apa fungsi? ada sstgh x wujud pon mcm tu
@fixfairuz1808 Жыл бұрын
Itu utk 'air release'.nnti sy buat video apa kepentingan paaip ini...xde pon xper tp ada skit risiko 'air locked'.
@amyzracing84782 жыл бұрын
Terima kasih pakcik atas perkongsian ilmu..
@mrjohn592 жыл бұрын
Nie namanya baypass tank. Air datang terus dari air paip ke bilik air. Bila air paip tak de baru, air dari tangki akan keluar. Sebenarnya tak bagus sebab air tangki disimpan terlalu lama, bakteria cepat membiak dalam air tangki. Cara terbaik air tangki harus sentiasa digunakan. Tarik paip dari tangki ke mesin basuh atau mane tempat yang sesuai. Jangan tarik ke sinki atau penapis air. Cara ini dapat mengurangkan pembentukan bekteria dalam tangki air.
@fixfairuz18082 жыл бұрын
blh bg 1 sbb knp air dr tangki tidak digunakan kalo ada bypass....? adakah air itu bersifat keras mcm batu? tidak blh bergerak walau sedikit? biat komen blh diterima akal
@fixfairuz18082 жыл бұрын
Pandai
@fixfairuz18082 жыл бұрын
nk tanya balik, apa kegunaan check valve @ 1 way valve? knp digunakan?
@fixfairuz18082 жыл бұрын
Ko ni giler ker aper.....try buat aper...dh beratus aku buat....ko pehal giler camni....?
@fixfairuz18082 жыл бұрын
Tgk video tu biar smpai abes...kan dh xfhm...org leng ok jer fhm...semua dh bgitau kt situ.. rasa xbetul, buatlh video awk yg betol sgt tu....tgk ada org nk tgk ker x....
@chabautv39992 ай бұрын
Saya ada satu soalan. Berkenaan sistem ni saya paham 100% .sebab dr background mekanikal. Tapi persoalan saya.tuan tak pasang check valve di inlet. Jika bekalan air main supply terputus.. adakah air akan berpatah balik ke meter kemudian akan sedut habis air tangki ke rumah kejiranan yg guna..ahhahaha.. paham kan soalan saya?
@k_hisyam39473 жыл бұрын
Kemah bossku.... Kemaman idaman
@zulcoyy65352 ай бұрын
Assalamualaikum tuan..salam dari borneo,, Alhamdulillah jelas pencerahan tuan ni,cuma ada 1 faktor yg saya x faham mengenai 1 btg paip bediri lurus dpn tangki tu utk apa ya? Spt dlm video ni,paip kluar dari tangki ada sbtg paip bdiri tinggi spt tinggi tangki trsebut,jadi minta tuan share apa kegunaan dya😊
@montoyapablo2089Ай бұрын
saya tlg jwpkn.boley yek.. paip vertical tu peranan nya utk support paip yg lalu diatas..so paip tegak tu kosong..cara ni dibuat bila poisition paip jauh dr dinding utk psng hook didinding.. juga utk paip di atas &bwh kukuh & nmpk kemas.. sbb ada support stand... klu salah sorry Bahh
@zixzaqlinz--3527 Жыл бұрын
xampamham amkumm ampem mendemm 🤣😂
@Repairje3 жыл бұрын
Terima kasih perkongsian tuan
@fixfairuz18083 жыл бұрын
sama2 tuan.moga bermanafaat...
@damai812910 сағат бұрын
Assalamualaikum, encik dari mana. Bolehkah kalau nak panggil encik baiki tangki air ni di rumah kami? Berapa kosnya? Terimakasih encik.
@shmid19 ай бұрын
Pemakaian Tanki air di perlu kn jika tekanan / kederasan ( main)sumber Air tidak mencukupi dan booster pump harus di beri pilihan jika tekanan air melalui gravity juga tidak mncukupi. Jika tekanan dari sumber air mencukupi maka tanki dan booster pump hya digunakn pada waktu2 darurat. Dari itu saluran atau piping line harus diubah sesuai dan adalh Terlebeh baek mngunakn pipe dan tanki yg terbuat dari bahan stainless Steel yg tahan lama dan tahan karat daripada mngunakn PVC pipe . Dalam isu ini Perlu diingat juga Tanki harus dirawat.
@mohdazri2110 Жыл бұрын
terima kasih atas perkongsian ilmu👍🏻 semoga Allah merahmati encik🤲🏻
Maknanya macam dairect paip jugak la kan, andai kata paip bilik air guna dua2 serentak.....dua bilik air, ada kemungkinan tak air kecil
@fixfairuz18085 ай бұрын
@@marhalimbain3635 2 paip tu akan lbh laju drp sblmnya
@mohdsaidi52745 ай бұрын
Tuan pertanyaan..kegunaan air tangki 2 saluran 1 kebilik air bawah..1 lagi ke bilik atas..masalhnya air bilik atas tk selaju bilik air bawah..jika sy pasang check valve utk bilik air atas shj..ada problem ke .dri segi kebaikan atau keburukkan..
@leo.640728 күн бұрын
Salam tuan, yg dari main/meter tak perlu letak check valve ke, kalau nak letak boleh tak. Kalau air syabas(contoh) tak ada jika tak letak check valve ada ke berkemungkinan air tank akan masuk ke paip syabas?
@shahrizalhashim7035 Жыл бұрын
Assalamualaikum tuan , t.kasih penerangan yg cukup lengkap , cuma sy nk tanya dekat paip utama dr meter x perlu letak check valve juga ke in case air dr meter utama tiada bekalan air , air dr tangki air akan pergi ke piping meter utama jika tiada check valve
@fixfairuz1808 Жыл бұрын
Kalo ada water filter xperlu dan air xkan melepasi meter air..meter air pun bersifat one way valve jg.......
@ThreeDeeWorld826 ай бұрын
Air xkan keluar melalui paip meter,sbb paip inlet dari meter berada d bhgian atas tangki..air xleh panjat masuk lubang paip..hehe
@wanmuzaidey30736 ай бұрын
Kalau nak buat sistem air utama xde air dan gunakan air tangki.mksd saya bila air meter takde auto air tangki turun..
@AzreenJafaar2 жыл бұрын
Nanti cuba
@abdullahhalimali81733 жыл бұрын
Terbaik lah bangunkan.
@shicibukaiW2 жыл бұрын
jazakallahu khair kasira ustaz fairuz
@namqulron3 жыл бұрын
Inlet paip (sebelum T - yg salur ke 2 paip outlet)perlu yg ada satu check valve, supaya air tangki tak turun ke meter, jika tiada bekalan air.
@fixfairuz18083 жыл бұрын
Blh letak kat slpas meter kalo mahu...kalo letak kat sblum T tu air xkn dpt supply pd bagian outlet direct dr main jika main pipe xde air
@zulhishamhashim75053 жыл бұрын
sy faham, sy pun berfikiran mcm tu.
@mfuadanuar82312 жыл бұрын
@@zulhishamhashim7505 saya pn faham mcm den maklumkan. Air dr tangki akan kembali ke main paip syabas. Check valve selepas stopcock
@alakhir90202 жыл бұрын
klau valve dpn tutup dia tidak akn ke mn2
@180MPH_In_The_Wrong_Lane2 жыл бұрын
@@alakhir9020 check valve yg selepas meter tu bertujuan mengelakkan terjadinya "sucking" @ negetive pressure @ back flow ke dlm mainline bila air tiba2 slow atau lagi teruk, air putus (kalau tak sempat tutup main valve). Semua air yg ada dlm service pipe kita tu blh tersedut balik masuk ke comm. pipe & main pipe syarikat air.
@apak66channel179 ай бұрын
Air dari main kena taruk check valve kalau tidak air akan gostan ke meter bila main X ada air
@rhsmedia793 ай бұрын
nak tanya, dari tangki tu ada dua outlet. selepas stock.cock saya nampak ada paip yang naik ke atas... yang tu pergi mana? atau atas ditutup (utk create pressure?)
@amatleha4644 Жыл бұрын
Salam tuan... Klau tak pakai tangki hitam tu... Bole ke pasang by pass tu
@fixfairuz1808 Жыл бұрын
yg ada tangki ajer tn....sbb dr tangki tu lah kita amik tekanan...
@amatleha4644 Жыл бұрын
Baik2... Tq
@bugisinside46976 ай бұрын
Ko masuk direct dari paip utama memanglah laju bonggok..aku nak tau dari tangki naper air slow walau dah ade overflow..tunjukkan cara dari tangki..
@ibnufirash83Ай бұрын
Perrgghhh... hebat benar kau bonggok kan org... kau nak minta tunjuk ajar dari org, tapi kau bonggokkan org tu... kau yg bonggok sebenarnya 😂😂😂😂 berbual konek...
@ahmadazhar869611 ай бұрын
salam tuan..klau kite psang valve je pda out dri tngki tanpa baypas dri incoming boleh ke???
@fixfairuz180811 ай бұрын
boleh dan tiada apa2 efek..
@syamil_vw10 ай бұрын
Paip masuk pun kne pakai valve ..law tak air dri tagki pulak masuk ke paip masuk law air masuk xdak
@zamribidin97794 ай бұрын
Lepas stock cock dari outlet tangki ada paip pvc yg tegak panjang tu utk buang angin ya... Ini you tak explain
@fixfairuz18084 ай бұрын
Bkn keperluan..ada ok..xde pon xper...
@manaiman88549 ай бұрын
Bang ada video cara pasang waterpump ke paip tangki ka
@salehsaleh220 Жыл бұрын
Tangki atas tempat tinggi bumbung mmg ada graviti dan tekanan.. Kalau tangki letak bawah rendah boleh ke buat gini tanpa water pump
@fixfairuz1808 Жыл бұрын
Sy blm pernah cuba...tp firasat sy akan laju lbh sikit shj...
@alienling69975 ай бұрын
Rumah saya dua tingkat. Bilik tingkat atas di bawah tangki tak ada masalah. Tingkat bawah tak ada masalah. Tingkat atas belah lain dari tangki, pressure rendah, sehingga shower tak ada air langsung. Ini masalah air lock ke pressure tangki? Saya cuba release airlock macam video KZbin macam tak berkesan, mungkin cara salah. Lebih baik pasang terus pump kat tangki atau modify tambah check valve macam ini dah cukup? Atau apa cara release air lock yang betul?
@sogekingable8 ай бұрын
Nak tanya. Kenapa x letak check valve kat incoming? Kalau incoming tiba2 xde air, air x balik ke incoming ke?
@syukrisyukri2551 Жыл бұрын
Kalau dah pasang bypass ni,mcm mne kte nk guna air melalui tangki .. adakah kena bukak kunci?? Dan mcm mne kte nk pkai air melalui direct? Kena buka kunci jgak ke..boleh terangkn mcm mne sistem dia
@fixfairuz1808 Жыл бұрын
pendek cerita...kedua2nya berfungsi. Tiada apa2 kunci diperlukan...stopcock yg dipasang itu cuma utk safety....jika ada paip bocor pd 1 bhgian.hanya tutup stopcock itu shj tanpa perlu tutup stopcock dkt meter air tu....jimat tenaga xperlu turun naik semasa kerja2 repai dilakukan.
@korea30082 жыл бұрын
Air dari paip main dah slow nak buat mcm aner
@fixfairuz18082 жыл бұрын
kalo dr main ke panggil Syabas @ mana konsesi negeri, mntak diorng bukak valve besar sikit....tp kalo tekanan stay rendah jgk kwsan tu terpaksa pakai pam elektrik lah
@ahmadmaidi4124 Жыл бұрын
Salam bro kalau kta pas g 1 way valve ni yg dri meter air adakah meter nya akan jd laju berpusing tak
@fixfairuz1808 Жыл бұрын
xde laju..nape nk gi ke meter lak..sy xbrp fhm tn.
@MuhammadKenYT2 жыл бұрын
ilmu yg bermanfaat bang.. terima kasih
@yapkh82 жыл бұрын
Hi fairuz. Sambungan paip di video utk brp bilik? Biasa rumah 2 tingkat ada 4 bilik mandi. 3 bilik mandi di tingkat 1 Dan 1 di tingkat bawah. Macam mana nak pasang bypass? Fairuz ada buat pemasangan di kawasan klang Bukit tinggi 2? Terima kasih.
@fixfairuz1808 Жыл бұрын
Biasanya outlet depent brp jumlah bila mandi biasanya...kalo ada 4, maknya ada 4 outlet....
@fixfairuz1808 Жыл бұрын
sent gambar dkt tangki air dr semua sudut kt wasap 010 339 2020 and i quot kos buat....
@pakatdiysendiri2 жыл бұрын
Cutter paip kita guna sm la bang...warna biru pun sm😂🤭
@ZuanhardieFamily3 жыл бұрын
bagus ini idea.. tapi saya nak buat lantai cam tuu lahhhh siapa leh buat
@fixfairuz18083 жыл бұрын
buat sendiri jer slow2 bang, nnti sy upload cara buat...
@eastsirr Жыл бұрын
Assalamualaikum bang… sy tgk abg ajar ni mcm sy boleh buat tp masalahnye jenis paip xsama😅… abg boleh tlg x cmne kalau paip lama main paip besi…outlet air ke toilet pvc… cmne sy nk buat bypass… umh sy paip mmg slow terus… penah pakai water heater yg ade pump pun xlarat nak pump…
@fixfairuz1808 Жыл бұрын
Waalaikumsalam, nk tanya, rumah ada tangki x? @ ambil direct semua dari main pipe? Kalo xpakai tangki xblh buat. By the way, pvc dan paip galvanised saiznya sama shj.... blh pakai samada penyambung yg ada bunga (threat). @ lbh senang gi kedai hardware tanya brng apa perlu pakai utk material paip lain jenis...
@eastsirr Жыл бұрын
@@fixfairuz1808ada tangki bang… cuma main paip air masuk tu jenis besi saiz rasa mcm besar dr paip outlet pvc dan bersaiz kecil sikit… ukuran saiz xbrp pasti sbb xde plak tulis kat situ…
@ayulestari3880 Жыл бұрын
Ada satu paip T yg pergi ke atas tangki sambung pg kmana bang?
@fixfairuz1808 Жыл бұрын
Itu paip utk 'air release, ketinggian mesti melepasi takat max. tangki...
@Royyap1008 Жыл бұрын
Hi , Boss , nak tanya , kalau Air Main tak masuk dekat by pass tu , kira air tangki juga akan turun balik pipe Main ke ?
@fixfairuz1808 Жыл бұрын
Betol...air tangki akan berfungsi spt biasa.....
@fahmiwahab3331 Жыл бұрын
Tak silap.Klu pressure dr main paip lebih tinggi dr tekanan tangki. Bypass flow selepas check valve xkan masuk ke laluan output. Hanya akan lalu jika press dr main paip lebih rendah dr tangki
@fixfairuz180811 ай бұрын
mmng tugas check valve @ one way valve utk air dr luar xmelepasinya....
@hihohuy Жыл бұрын
dah buat macam ni, tapi bila test air incoming tutup air keluar dari tangki utk ke tandas jadi sangat slow... macam mana ye?
@fixfairuz1808 Жыл бұрын
Ada kemungkinan kesilapan lokasi pemasangan check valve @ ada kerosakan pd check valve @ mungkin ada angin dlm piping... kene check 1 per satu...
@unaldiroslan5147 Жыл бұрын
Kalau buat macam ni pasang check valve, air dari tanki dah tak boleh guna lah ya?
@fixfairuz1808 Жыл бұрын
Air tangki akan keluar spt biasa dan dibantu tekanan keluar bersama air direct dari meter.....kalo tanya percentage sy kurang arip cara nk kira...ttpi bergantung pd keadaan graviti smadasama byk atau salah satu akn keluar minima, satu lg kwluarkan air secara maksima...
@mohdshujairi421 Жыл бұрын
Klu dari meter terus tak pkai tangki boleh buat dak
@fixfairuz1808 Жыл бұрын
Blh sangat dan xperlulh pakai check valve.....tp kalo semua direct dr meter air nnti air xde semua xleh pakai tau...dan air tangki nnti dh rugi xguna.....
@zulhakimibahtiar436 Жыл бұрын
apoo🤣 aku okay je potong poli pakai grgaji, brtahun² dh buat plumber, xde kluar pun air. jnji pasang soket tu btul, xde trbalik².. potong pun kena lurus.. 🤣🤣
@FreemanSurplus Жыл бұрын
tu bezanya profesional dan kampung
@malikimulkan8673 Жыл бұрын
@@FreemanSurplusapa kena mengena dengan kampung lak? kau duk profesional ke duk bandar? nak buat perbandingan pun tak betul.
@fixfairuz1808 Жыл бұрын
Bila kita hendak menjadi guru biarlah ajar benda yg betol, selamat dan memudahkan..apa guna sesuatu alat dicipta?.apa guna compressor dicipta walhal berus cat lg murah...samalah perbandingan apa yg kamu kata gergaji pon blh....bkn setakat gergaji, dengan parang pn blh....kdng2 soal keselamatan pon kene fikir jgk...kualiti kerja pasti bagus jika kita menggunakan peraltan yg betol....itulh yg dipanggil orang 'kompetan' dlm dunia teknikal...
@zehanbadri378321 күн бұрын
Berapa kosnya tu bos , kalau nak pasang semacam tu bos .
@nanamihakuto6639 Жыл бұрын
Salam...boleh nak tahu kalau pakai sistem paip mcm ni...di mana tempat nak letak pump air ye tuan....pump utk tarik air masuk tangki
@fixfairuz1808 Жыл бұрын
Waalaikumsalam...cuba google ' cara betul pemasangan booster pam... dia ada gambarjah...sy nk terangkan pon pnjng sgt....
@jamesundau87902 жыл бұрын
Informasi yang berguna.👍👍 Mahu tanya. Kalau jenis valve mana yang lebih sesuai? Spring valve atau flat valve?
@fixfairuz18082 жыл бұрын
Keduannya sesuai tetapi bergantung pd kualiti produk itu sendiri....
@kamisanatanashari90372 жыл бұрын
Saya rasa kena ada 1(satu) lagi check valve bagi menghalang air dari tangki keluar dan masuk kedalam paip dari meter semasa bekalan air terputus. Tanpa check valve ini air dari tangki akan keluar terus walau tidak digunakan. Tetapi air dari tangki akan keluar beri bekalan kepada org lain melalui paip dari meter. Sekian.
@azrulaswad62912 жыл бұрын
Air dari tangki xkan keluar dh ikut situ kalau bekalan air trputus sekalipum...sebab kedudukan paip utama air masuk ketangki adalah paling tinggi dan di atas paras maximum air didalam tangki...hanya air yang didalam paip utama sebelum masuk tangki saja yg akan keluar kembali jika bekalan air terputus... Kecuali la klau ada tukang paip yg letak paip utama masuk ke tangki tu paras bawah..mcmmna pelampung tangki nk brfungsi...😆😆😆
Setuju dgn sdr kamisan.. Betul dan sepatutnya kena pasang 1 lg check valve di bypass pipe bagi menghalang air tangki terus keluar ke main pipe masa bekalan air terputus..
@mrjohn592 жыл бұрын
Tak perlu, sebab dekat main paip dah ada,Check valve. Untuk mengelak air selepas meter patah balik ke paip utama boleh tengok dekat meter paip masing dia ada anak panah, cuma model dia jea lain sikit. Tapi fungsi tetap sama.
@MrFazley2 жыл бұрын
@@azrulaswad6291 itu air direct masuk ke tangki dr atas tangki..kan dh buat bypass di bawah..2 outlet dr tangki bersambung dgn paip air direct boss..
@mohdiliyas82183 жыл бұрын
Salam tuan..saya rasa tuan tertinggal 1 lagi check valve untuk paip incoming supaya bila incoming tiada air..air tidak tendang balik masuk tangki dan air ke main paip..maaf kalau salah pendapat...
@fixfairuz18083 жыл бұрын
ya...kalo rumah kita level lbh tinggi dr rumah orng lain mesti pakai 1 check valve slps meter air...
@ajoyrosle54463 жыл бұрын
Term yg betul ialah non return valve.. So that the water flow could only go in one direction.. If there is a problem with the supply from mains, the water would stay put..
@mohd.rozizainuddin48843 жыл бұрын
betul 'non return valve'.
@khazaasrar98953 жыл бұрын
same je check valve dgn non return valve..term je berbeza
@zaminturan46102 жыл бұрын
Assalam sya nk tya bolh dak kita nk bypass tangki air.. mksd sya sya tngki air tu x dok kt tmpat tnggi.. tapi kita bypass di bawah dan hbung ke bilik air dan kegunaan untk dapoq smua.. bolh dak spa2 yang tau tlong jawab
@fixfairuz18082 жыл бұрын
seeloknya kita bypass tmpat ada tekanan spy air menjadi laju...blh cuba dulu buat 1...try and error... then kalo xfhm blh tanyer lg nnri...
@goldmining100 Жыл бұрын
Terbaik penerangan tuan, sy dh pasang cv mmg air dlm bilik air laju, cuma nak tanya bila tutup stopcock utama naik ke tangki air dlm bilik air jadi slow sangat, apa masalahnya ya tuan?
@fixfairuz1808 Жыл бұрын
Pressure dr main pipe yg bantu lajukan air....jika tiada aliran dari main, pressure akan jd sedia kala
@charleschin64972 жыл бұрын
Encik, adakah penggunaan check valve perlahankan aliran air/mengurangkan tekanan air?
@fixfairuz18082 жыл бұрын
menguatkan tekanan aliran air
@syafiqJoeBUSS-cz3fn Жыл бұрын
Salam tuan buat area mana? Area Melaka boleh buat ke?
@fixfairuz1808 Жыл бұрын
Sy di Sepang.... Melaka agak jauh... tp ada jg customer sanggup bayar add. charge... blh brhbng dgn sy ditalian wasap 0103392020
@razaliniruji99157 ай бұрын
Kalau rumah ada 3 bilik air berasingan (ada shower, sinki dan tandas) tekanan nya masih tinggi ke atau kurang?
@fahmiefahim7032 жыл бұрын
Salam bang terima kasi ilmunya Cuma mau tanya sambungan bypass dr meter tu tak perluka pasang oneway valve sbb air dr tgki akan bepusing balik masuk ke tangki ikut laluan by pass tu sbb drumah saya mcm tu terus overflow@ rumah saya ketinggian tangki tak betul
@fixfairuz18082 жыл бұрын
ni. overflow, kemungkinan kedudukan valve xbetul...tuan kene lukis mngkin sy akan fhm....penerangan tuan xbrp jelas.
@FakhruddinMohammad-v2p2 жыл бұрын
Sepatutnya air dari tangki takan masuk balik ke paip utama bila tiada air masuk sebab paras air masuk dalam tangki adalah tinggi (bersekali dengan pelampung).
@chabautv39992 ай бұрын
kan dia dah bypass td😅.. bukan keluar dr pelampung tu.. keluar dr outgoing la masuknke meter balik.. sebab dalam kes ni dia dah bypass incoming dan outgoing dr satu paip dan laluan yg sama.. one way valve hanya menghalang incoming masuk ke tangki melalui outgoing..tapi dia tak halang dr outgoing ke meter sebab dia tak pasang one way valve kat incoming.. tp saya ada baca komen.. air dr dalam rumah tak kan melepasi meter sebab meter tu pon sebenarnya bersipat one way direction jugak..
@chowwilson9098 Жыл бұрын
Kalau ayer pressure ta- kuat boleh-ka ? Saya pasang check valve bagi dia kuat Dari tanki ke rumah atas . Terima kasih .
@fixfairuz180811 ай бұрын
sbnarnya bypass tugas dia utk bantu kuatkan pressure tetapi utk betol2 kuat terpaksalah pakai pam...
@AmeenHandyMan Жыл бұрын
saya dah buat check valve dari tangki tak mau bukak dari pressure tangki tak kuat nk tolak valve tu kalau tutup air direct.. maknanya dia guna pipe air direct je sebenarnya.. tutup direct dari tangki tak keluar setitik pun.. jd tak ada function la air tanki.. igtkn bila buat sistem mcmni air tangki dgn air direct bertembung jadi labih kuat air.. rupanya bukan.. hmmm dia baypass jd sistem tangki stop direct je yg jalan.. kalau direct mcm air luir meleleh mmg xfunction langsung.. rasa kecewa pulak.. hmmm
@fixfairuz1808 Жыл бұрын
Pertama tuan kena pastikan sambung dan kedudukan check valve itu betul....kedua pastikan juga tiada mana2 paip yg tersumbat @ ada halangan utk mengalir secara sempurna... ketiga baru kita check keseimbangan graviti pepasangan kita.....
@al-fatihmuhamadiah22248 ай бұрын
Yg paip menegak ke atas tu utk apa (apa tujuan dia) ...
@al-fatihmuhamadiah22248 ай бұрын
Saya nak tahu ... kenapa ada overflow sedangkan dah pasang pelampung baru air masuk ke tangki ...
@matyo41517 ай бұрын
kadang2 komponen dekat pelampung tu boleh rosak. jadi waktu ni overflow berguna