All respect to the simplicity of providing such a crucial subject in HVAC desdign information.
@avinashshewale2254 жыл бұрын
Kya baat hai sir ji aapne To itne simple se bataya ki Me is system ko use kar sakta hu aur muje ise sahi me bohot hi fhayda hoga. Thank u sir God bless u.
@rizwanaif13204 жыл бұрын
Really you r doing very good job.Love u from pakistan .
@hvacsimplified4 жыл бұрын
Welcome Rizwan
@tanveeralam36752 жыл бұрын
Sir,bahut achhe se samjhaya aapne...thank u
@zafarchaudhary90936 жыл бұрын
बहुत ही स्वीट explanation sir...kitni tareef kru kam hi hogi...really sir
@hvacsimplified6 жыл бұрын
Thank you. keep watching
@ejazahmedshaikh4616 жыл бұрын
Very sweet and simple explanation sir. Very nice video sir
@hvacsimplified6 жыл бұрын
Thank You, keep watching.
@vipulsrivastava8114 Жыл бұрын
Very nicely explained 👏🏻👏🏻
@asif11996asif4 жыл бұрын
Respected sir, Further to your video about Toilet Exhaust system design and calculation what i learned is 4*3*3 = 36 Area Volume 10 = Air changes per hour therefore 36*10 = 360 meter cube per hour and as all we know 1 meter cube per hour = 0.5886 cfm Then 360*0.5886 = 211 ( Finally answer is same ) Thank you for your support and guidance.
@hvacsimplified4 жыл бұрын
Welcome.
@TheSilocas4 жыл бұрын
211 CFM is for 1 toilet ?
@tanveeralam36752 жыл бұрын
Pls sir ,1 video vrv/vrf ka boq ductable units k lie aur 1 video flexible duct ka length kaise measure karte h...upload kar dijiye
@ichfan98113 жыл бұрын
Thank you Sir, your explanation was very helpful
@satishpagare81376 жыл бұрын
Very nice video sir... I am big fan of yours.. Thanks for helping us
@hvacsimplified6 жыл бұрын
Thank you Satish, if my work is beneficial to you all.
@jupiterbrothers26502 жыл бұрын
Nice video..
@sweethumanissmsubbu592 Жыл бұрын
Super sir thank you
@mossalam34316 жыл бұрын
Sir I am big fan of you, Your explanation way is very awesome
@hvacsimplified6 жыл бұрын
Most welcome Salam. Thank you for your comments. Keep watching and always let me know if you have any questions
@bimmakersonline4592 жыл бұрын
hi there please upload kitchen exhaust design (exhaust ,fresh air and air conditioning ) and car parking (jet fans with exhaust and fresh air in cellar )
@mohammadnazim18093 жыл бұрын
Sir aap ne bhaut aache se samjhaya h thanks lekin mera 1 question h ki method 1 me to private and public toilet ki calculation kar lenge lekin method 2 me to aisa kuch aap ne bataya nahi h kia uss ka common rahe ga dono ke liye . Sir please reply when you are free I am waiting for your valuable reply Thanks
@apjamshi4 жыл бұрын
Please make a video for kitchen extract design and calculation
@Trendingpower2135 жыл бұрын
Sir treated fresh air kaese calculate karte h plz make the video for TFA
@mossalam34316 жыл бұрын
Sir keep on
@ericg.magnaye68996 жыл бұрын
Please make a video for kitchen hood calculation and cooling load calculation. thanks
@hvacsimplified6 жыл бұрын
Sure, They are on the list of upcoming videos
@apjamshi4 жыл бұрын
Kitchen hood s very important. Please
@mohammadehteshamulhaque30172 жыл бұрын
Hi... What should be the ACH for the OWC and STP room
@kamalpreetsingh43566 жыл бұрын
Very Nice Sir ... But were using same design to calculation both method CFM calculation
@rajan40335 жыл бұрын
Sir pls create a video for tunnel ventilation system.
@apjamshi4 жыл бұрын
Support
@RahulSingh-ve8yx6 жыл бұрын
Sir kindly explain in detail about VRV System work mechanism.
@apjamshi4 жыл бұрын
Please . Vrf is important
@ar.avadheshsingh26164 жыл бұрын
Sir please private residence toilet ka mechanical ventilation kaise kre
@hvacsimplified4 жыл бұрын
I will be making videos on Ventilation and Exhaust shortly
@xcuted_rizwan_16705 жыл бұрын
Very good video
@ganeshkamble68924 жыл бұрын
Can you please explain on Villa or Bungalows exhaust and fresh air systems and ducting.
@ufi31826 жыл бұрын
Sir I want to know how can I start a HVAC installation business and what things and knowledge should I have regarding this...I mean the useful charts of standards. Please answer in datail I will be very thankful to you.
@hassanfaraz4 Жыл бұрын
how much CFM /sq. ft required for Residential and commercial kitchen?
@maheshpawar21044 жыл бұрын
Thank you sir🙏
@hvacsimplified4 жыл бұрын
Welcome
@letslearntogether11176 жыл бұрын
sir could you please do a full video on how to draft hvac duct system for a particular project???
@hvacsimplified6 жыл бұрын
Acknowledge.
@apjamshi4 жыл бұрын
In the case of a labour accomodation public toilet, ,we use package unit for one floor to cool including toilet. In this case 80% supply sir means, 80%of the total supply or 80%supply sir in toilet only.
@RajendarKumar-di7qn4 жыл бұрын
Please make kitchen ventilation wall mounted type with calculation
@syedzakirhussain10846 жыл бұрын
very nice initiative Keep going In this video fresh air which 80 % is supplied with fan or just fresh air louver is sufficient
@sathyan11206 жыл бұрын
Sir Do u have any android apps for ducting autocad
@mechtrotip50344 жыл бұрын
How to perform heat load calculation for negatively pressurised room?
@mossalam34316 жыл бұрын
Sir Fcu ka troubleshooting ka ek video please banayein. complete with drv , actuator connection.
@irfanali-jg6or6 жыл бұрын
sir plzz upload VRV calcultion video and pump head calculation sheet
@mateentaj3993 жыл бұрын
Thanks
@letslearntogether11176 жыл бұрын
sir for the first method is the passing area the same as we get when we type AA command in autocad???
@Behuman06276 жыл бұрын
can we consider this same formula for Bedroom & living room also? please advice!!
@hvacsimplified6 жыл бұрын
Dear Sanjay Bedroom & living room air do not need to be exhaust
@Behuman06276 жыл бұрын
HVAC Simplified Online Training - By AMK Dear Sir, the project I am working we have exhaust in Living room & bedroom As well...
@hvacsimplified6 жыл бұрын
The room are to be maintained at negativity pressure or positive ? In any case you need to calculate the exhaust and then provide it in the software individually then the software will calculate it based on that.
@raeeskhan29283 жыл бұрын
I would kindly request you take a look at your formula again. CFM= Cubic feet Minute, when you are calculating the volume of the room you need three dimension. LxWxH I hope this will help.
@belalahmadshaikh9396 жыл бұрын
Sir cold room calculation Ka video banaye please
@vishnusharma14095 жыл бұрын
Sir static pressure kitna Lena h
@KanchanKumar-Deoria6 жыл бұрын
good video...kuch widely explain karo...because this is so similar video of another channel named.#$#$$#.
@hvacsimplified6 жыл бұрын
Thank You Kanchan, Our intention is for a good cause and to help everyone understand the subject. There are infinite videos on same topics for the same subject. The ways of explanation will differ from person to person but the technical parameters & formulas will have to be the same.
@abdulyazdani55526 жыл бұрын
Hi sir.can u make ventilation static pressure.
@kanesoterol66113 жыл бұрын
Where did you get 1.7?
@mosaedalhaffar83845 жыл бұрын
Dear sir ,can you explain in english please
@mohammed5yaz9855 жыл бұрын
sir i need round exhaust duct static pressure calculation please
@hemalshah40496 жыл бұрын
Thank you sir..
@hvacsimplified6 жыл бұрын
Welcome Hemal.
@nikhiljagtap41315 жыл бұрын
Sir ducting ki siz kase nikale
@anudeep53526 жыл бұрын
I need CSU explain
@richarddsilva22414 жыл бұрын
What is 10
@nikhiljagtap41315 жыл бұрын
Nahi sir,wrong aa raha 13×9×9×10÷60=175.5
@neon_gamer127coolguy42 жыл бұрын
I don't understand what are you saying in hindi!
@anudeep53526 жыл бұрын
Csu
@hvacsimplified6 жыл бұрын
If the adjusent space is air conditioned the a door louver or door under cut will take the fresh/supply air from it. (Mechanical fresh air is not necessary)
@syedzakirhussain10846 жыл бұрын
very nice initiative Keep going In this video fresh air which 80 % is supplied with fan or just fresh air louver is sufficient