What is the possible cause in tornatech spklr pump showing phase loss L1 when running. What checks to be done can help me ? Thanks
@ajo_vlog10 ай бұрын
My be that can from current Transformers CT
@electrodancemovement_music89216 ай бұрын
You press Stop push to stop pump?
@jijothomas6250Ай бұрын
duty pump auto matically start why
@VigneshTssecc2 ай бұрын
Hi. Our vizitouch v2 controller is not powering up after the shutdown and then restart. What is the reason..?
@Hamed-bo5tm3 ай бұрын
Hello How can I reset alarm of Io Expansion 1 communication Error?
@fazsltda7 ай бұрын
Hello, where do I change the IP address?
@mathewabraham669510 ай бұрын
Hi After setting the motor working automatically when pressure loses, the motor runs only in Delta. Visually we checked the Star contact, not working. Can you explain why the motor is running directly Delta.
@engineersguidehelp10 ай бұрын
hello, for that you can check the wiring of the motor, and secondly remove the motor contact from the controller and run just the controller without any load, check this 2 and update me thank you
@zetabola12 жыл бұрын
Hi, and the default password is......??
@mohammadalam10665 ай бұрын
I have 2 pump electric and diesel pump but both controller showing different pressure how to make equal please explain
@engineersguidehelp5 ай бұрын
you have to calibrate the pump controllers
@DineshMishra-z3q5 ай бұрын
Different pressure showing in the controller panel so why need to calibrate the pump ?
@zahidullah57242 жыл бұрын
Dear I have a question Pressure down from 118 psi the pump was started but why not give pressure there have mention (pump on demand))
@Richards_Travel Жыл бұрын
check your sensing line
@marwanmostafa52886 ай бұрын
Hello brother my electric fire pump trips when shift to delta
@engineersguidehelp6 ай бұрын
@@marwanmostafa5288 remove the load from the controller and try running the controller alone, if it works,then check you pump termination, update me once done
@ahmedtijany8491 Жыл бұрын
Pump didnt stop by cut out pressure .. and cant stop automatic .. cut out 8 bar but it still running
@princemuhammadfaisalakberk6595 Жыл бұрын
Bro check set pressure also check cut of time
@alywaheep1125 Жыл бұрын
How we can solve pt sensor fault
@peermohaideen6126 Жыл бұрын
Excel excellent fire system
@amitking110011 ай бұрын
How to find run hours of pump
@كهرباءعامة-ب7ق6 ай бұрын
How I can runing manual
@engineersguidehelp6 ай бұрын
@@كهرباءعامة-ب7ق just push the green button it will run manually
@aljeansalvador55962 жыл бұрын
i thank i know you? 🤔 how about fire pump tripping power how to resit?
@engineersguidehelp2 жыл бұрын
If it's persistent remove the load from the controller and try powering it on if it comes on inspect Ur motor it may be faulty
@shahidbashir9244 ай бұрын
Max Pressure of PT1 is 1 to 600 PSI
@deard46762 ай бұрын
How to this password plz.help me any on
@engineersguidehelp Жыл бұрын
HELLO THOSE THAT ARE ASKING FOR PASSWORD,PLS ANYONE WHO IS AN AUTHORIZED USER HAS TO HAVE THE PASSWORD FROM THE SUPPLIER TO MINIMIZE MORE DAMAGES TO BE CAUSED WHEN ITS SHARED HERE ....PLS CONTACT YOUR SUPPLIER THANK YOU