Training - M221 - M14.5 Linking variables from M221 to EcoStruxure Operator Terminal Expert

  Рет қаралды 6,913

LeTomas AHUMADA

LeTomas AHUMADA

Күн бұрын

Training - M221 - M14.5 Linking variables from M221 to EcoStruxure Operator Terminal Expert
In the version V3.2 SP2 of the software we have on the Equipment a variable called "ErrorFlag
" that when there is a communication error, this flag is set True but we need to manually reset the flag after confirming the error.
The software EcoStruxure Machine Expert Basic (former SoMachine Basic) allows you to program the Modicon M221:
www.se.com/ww/...
The software EcoStruxure Machine Expert Basic is Free, you need to have an account in our License Portal in order to register it:
www.se.com/ww/...
In order to program the Modicon M221 you can use a miniUSB cable (TCSXCNAMUM3P or BMXXCAUSBH018).
Playlist of the training:
• Modicon M221 - Training
EcoStruxure Operator Terminal Expert (former Vijeo XD) is the software that allow us to program the Harmony HMIs like:
•HMISTO7: (not the HMISTO5 or HMISTU)
download.schne...
•HMIST6 / HMISTM6:
download.schne...
•HMIGTU:
download.schne...
The software can be download from the next link (check in se.com):
download.schne...
After the installation of EcoStruxure Operator Terminal Expert, the trial version of the software is available for 42 days and will have to be activated with the commercial license. In UK we only have the printed licenses.
In trial version the download option for USB , Ethernet or File System is disabled.
For more information please access to digicat.se.com/ or direct to the catalog:
download.schne...

Пікірлер: 31
@hichemam2733
@hichemam2733 2 жыл бұрын
Another great video 🤝 , thank you so much
@LeTomasAHUMADA
@LeTomasAHUMADA 2 жыл бұрын
You are welcome 😊 working on the HSC tutorial 😉
@hichemam2733
@hichemam2733 2 жыл бұрын
@@LeTomasAHUMADA ❤️ thank you so much Mr AHUMADA ❤️ I'm eagerly waiting for it
@franciscojaviercuevaschave7631
@franciscojaviercuevaschave7631 Жыл бұрын
Excelente video
@LeTomasAHUMADA
@LeTomasAHUMADA Жыл бұрын
Gracias Francisco 😊
@oscarosoriosevilla8127
@oscarosoriosevilla8127 4 ай бұрын
good explanation Leandro, but i cannot import memory bits from a project of M221 using symbol link. When i choose the option Somachine file name driven all the variables are imported except memory bits. How can i do to fix this issue?
@LeTomasAHUMADA
@LeTomasAHUMADA 4 ай бұрын
Hi there! I will probably try the following: 1) Check that the %M variables have a name (symbol name). 2) Check that the smbp file selected is the correct one. 3) Use the latest version of EcoStuxure Operator Terminal Expert (the latest version is the v3.5)
@ujjwalrathod007
@ujjwalrathod007 5 ай бұрын
Is this alternative video to the one with is using Nodename to connect to the PLC?
@LeTomasAHUMADA
@LeTomasAHUMADA 5 ай бұрын
Hi there! To connect to the M221 with an hmi in eote we need to use ip address not the nodename
@cristiangallardo8482
@cristiangallardo8482 Жыл бұрын
Hola Leandro, gracias por la serie de videos! me sirvieron mucho. quería consultarte si hay alguna manera de cambiar la carpeta de las variables una vez que estas ya fueron creadas??? Graciass! Saludos! vamos la scalonetaaa
@LeTomasAHUMADA
@LeTomasAHUMADA Жыл бұрын
Buenas Cristian! Cuando se usa el SymbolLink el software crea una carpeta a la cual no podemos modificar el nombre lamentablemente. Como alternativa, no lo probe, podrias exportar las variables desde el EOTE y modificar el archivo con la propiedad de la carpeta para que no aparezca en el symbollink (si mal no recuerdo el nombre de la carpeta es igual al nombre del driver, este al ser importado debe ser distinto). Saludos! Vamos Argentina!!! 💪🏻🇦🇷
@NelsonGCR
@NelsonGCR 2 жыл бұрын
Nice video Mr. Leandro. Keep up the good work! If I may, I want to ask you something... Does Schneider provides any instrument (software) to programm an interface for, let's say, the M221 but using a tcp/ip or web server? Or you should assemble the html by yourself? Thank you for your time.
@LeTomasAHUMADA
@LeTomasAHUMADA 2 жыл бұрын
Hi NelsonGCR! The modicon m221 does not have a webvisualization like the m241/m251/m262. If you need a webserver then probably the best is to have an small hmi like the hmisto735 + webviewer license.
@NelsonGCR
@NelsonGCR 2 жыл бұрын
@@LeTomasAHUMADA Great. So, at least that option is available using that device. Thanks again
@user-hc7ec8wx3n
@user-hc7ec8wx3n 5 ай бұрын
.smbp file, how to get it from ecostructure machine expert? What address I should use for device in variable declaration?
@LeTomasAHUMADA
@LeTomasAHUMADA 5 ай бұрын
Hi there! the modicon M221 is no longer include the EcoStruxure Machine Expert, please check this video: kzbin.info/www/bejne/rHPRkGSjj9KCj6s You will need to open the EcoStruxure Machine Expert Basic to program the M221. If you need assistant with the variable declaration please check the following video: kzbin.info/www/bejne/rqS2kH2EnJJog68
@debasmitabisoi8469
@debasmitabisoi8469 10 ай бұрын
Hello. How to export the database from s7 1500 to ecostruxure operator terminal expert
@LeTomasAHUMADA
@LeTomasAHUMADA 10 ай бұрын
Hi there! As i do not have a s7-1500 with i will not be able to guide you as a guide using schneider products. In this particular case i recommend you to check the help on the hmi software.
@Amerigo_Vespucci
@Amerigo_Vespucci Жыл бұрын
Is there a way to set %MW to UINT 0-65535? - I want to save the value read by serial IOScanner from slave device to MW. But MW seems to be INT -32,768 to +32,767. Can I change that?
@LeTomasAHUMADA
@LeTomasAHUMADA Жыл бұрын
Hi there! In this particular case i recommend you to use %MD instead of %MW
@carlosmartinezochoa6069
@carlosmartinezochoa6069 Жыл бұрын
Buenos días, estimado Leandro Tomas Oscar Ahumada: Deseo que este muy bien al igual que su familia. Sus videos son muy interesantes, están muy bien preparados con un gran dominio de la Automática y de los autómatas de Schneider. Quisiéramos hacer un observador de estado con un autómata, tenemos un autómata M221 de Schneider, estamos utilizando el programa SoMachine, por favor, si le es posible, nos podría decir cómo obtener la integral de z3: z3=L*(y-z1) tenemos los valores de salida del sistema (y), la salida estimada del sistema (z1) en bloques de operación. L es una constante. Le agradece mucho toda su atención, Carlos E. Martínez Ochoa
@LeTomasAHUMADA
@LeTomasAHUMADA 3 ай бұрын
Buenas Carlos, espero que vos tambien estes bien. A esta altura creo que ya hiciste la integral 😅. Si usas el pid del m221 no tenemos acceso a esta informacion por ende el calculo debe ser manual. Si es manual entonces deberas tener en cuenta el ciclo de scan para calcular el valor del ciclo actual con el anterior.
@LeTomasAHUMADA
@LeTomasAHUMADA 3 ай бұрын
Hace mucho tiempo atrás hice una planta y control discreta pero usando otro plc (m258) ya que me daba la ventaja de usar texto para programar el código.
@picklejuicedan1346
@picklejuicedan1346 5 ай бұрын
Can I write to varibles on the PLC? Im trying to write to a simple contact bit from the simulator. Changing it from 0 to 1 and vice versa but it doesnt change. However its able to read the bit when I force a bit value. Im using the trial version of Terminal expert.
@LeTomasAHUMADA
@LeTomasAHUMADA 3 ай бұрын
Hi there! Unfortunately my knowledge on the trial is very limited... i am aware that you can not download the application to an HMI and the trial is only for 38 days... i think that there is not a limitation for connection.
@mahirkubilayozturk114
@mahirkubilayozturk114 2 жыл бұрын
Hi Mr.Ahumada I have a problem. I can't to transfer my variables from MS Excel to operator terminal expert. How can I transfer? Could you help me for this please
@LeTomasAHUMADA
@LeTomasAHUMADA 2 жыл бұрын
Hi Mahir, the HMI software required an an specific syntax of the content inside the file to make the import valid. Please check the next video: kzbin.info/www/bejne/iavUgJZqZpuCo6s You can also try to match the export file in your app with the one you want to import.
@mahirkubilayozturk114
@mahirkubilayozturk114 2 жыл бұрын
​ @LeTomas AHUMADA Hi thanks your information Mr.Ahumada. But I have a M580 and I haven't Unity veriables menagement for operator terminal expert not exist in my license file. I download your file but It's not working for my cpu m580. Do you have any other solutions? Thank you in advance for your interest
@LeTomasAHUMADA
@LeTomasAHUMADA 2 жыл бұрын
@@mahirkubilayozturk114 the videos that i am uploading are not related with M580/M340 platform. You will need to export from CE or UnityPro a XVM file with the variables you want to share with the HMI then in the EOTE you can import the XVM file in the symbol link after the driver has been added. If you need further information contact the technical support team of schneider in your country.
@SirHayk
@SirHayk 2 жыл бұрын
What Modbus SIO stands for? is it Modbus RTU?
@LeTomasAHUMADA
@LeTomasAHUMADA 2 жыл бұрын
Hi Hayk! Good question. I may have no answer for this but the driver "Modbus SIO" is for Modbus Serial communication. If I am not wrong the SIO can stand for Serial IO but I am not 100% sure.
Training - M221 - M15.1 Introduction to Pulse Width Modulation (PWM)
22:38
EcoStruxure Operator Terminal Expert - How to use alarms
40:59
LeTomas AHUMADA
Рет қаралды 7 М.
女孩妒忌小丑女? #小丑#shorts
00:34
好人小丑
Рет қаралды 85 МЛН
Prank vs Prank #shorts
00:28
Mr DegrEE
Рет қаралды 10 МЛН
Matching Picture Challenge with Alfredo Larin's family! 👍
00:37
BigSchool
Рет қаралды 47 МЛН
这三姐弟太会藏了!#小丑#天使#路飞#家庭#搞笑
00:24
家庭搞笑日记
Рет қаралды 92 МЛН
A DAY (NIGHT) in the LIFE of a NOC ENGINEER!
12:36
Custodian Data Centres
Рет қаралды 1,8 МЛН
Top 5 Beginner PCB Design Mistakes (and how to fix them)
12:52
Altium Academy
Рет қаралды 215 М.
女孩妒忌小丑女? #小丑#shorts
00:34
好人小丑
Рет қаралды 85 МЛН