Transformer Inrush in 5 minutes

  Рет қаралды 39,995

Daniel Lang

Daniel Lang

Күн бұрын

A brief description of transformer inrush.
Music by: David O'Brien

Пікірлер: 22
@mayurbalwani7277
@mayurbalwani7277 7 жыл бұрын
You nailed it! That's the best video about the inrush phenomena on the internet! No bullshit, just to the point explanation! Thanks a lot man! God bless you! :)
@pedrodepacas4335
@pedrodepacas4335 5 жыл бұрын
The music is good humor I appreciate. Sounds like college radio.
@olfertholte1446
@olfertholte1446 8 ай бұрын
BEST PRECISE EXPLANATION ON THE WEB! thanks alot!
@jessstuart7495
@jessstuart7495 Жыл бұрын
Nice explanation. Clear and concise. Thank you.
@stevecanny1583
@stevecanny1583 8 жыл бұрын
Awesome video Daniel, thanks very much!
@santiago18220
@santiago18220 4 жыл бұрын
Excellent video
@svbrmk
@svbrmk 8 жыл бұрын
Excellent Video! Thanks a lot!
@AshleyTennyson
@AshleyTennyson 7 жыл бұрын
thanx a ton man! amazing explanation
@geor664
@geor664 5 жыл бұрын
Excellent Theoretical content but the music is highly distracting. You need to ditch the muzak.
@888899991
@888899991 7 жыл бұрын
well organized
@irajnoormanesh9805
@irajnoormanesh9805 6 жыл бұрын
thank you
@uptide1214
@uptide1214 7 жыл бұрын
this music
@AhmedMujtabaAwan
@AhmedMujtabaAwan 6 жыл бұрын
Why the music?? really disturbing! otherwise great explanation.
@dominiquedeveaux361
@dominiquedeveaux361 2 жыл бұрын
I found it pretty relaxing and really liked it :) Different tastes i guess
@dominiquedeveaux361
@dominiquedeveaux361 2 жыл бұрын
nvm i see what you mean. Distracting*
@albertdebobes8330
@albertdebobes8330 4 жыл бұрын
Hey! Thanks for the video. I understood how that peak inrush current appears, and that the saturation of the core would damp out the flux until converging into its steady-state value. But what if you had a core that allowed higher currents? That is, when the inrush current occurs, that the core didn't saturate. Would then the inrush current be there perpetually?
@dominiquedeveaux361
@dominiquedeveaux361 2 жыл бұрын
At 2:32 shouldnt the units of H be (A/m) and not (At/m) ?
@jasinaj5397
@jasinaj5397 5 жыл бұрын
how to avoid these unwanted tripping from CB s ,because of this phenomenon
@anupamsrivastav0103
@anupamsrivastav0103 4 жыл бұрын
Generally CB for such circuit comes with CSD (controlled switching device). It delays operation of CB until inrush phenomenon is over.
@bobcocampo
@bobcocampo 4 жыл бұрын
Increase font
@MrSummitville
@MrSummitville 3 ай бұрын
Why did you add the annoying background noise? Explain to me how that noise makes it easier to hear and understand what you are saying. Use your brain ...
@cancian123
@cancian123 6 жыл бұрын
music sucks man. It is very hard to understand you because of the music
Understanding Transformers Part 1: Inrush, Saturation and Fusing
22:43
Transformer saturation and gapped core current transformer
17:19
Sam Ben-Yaakov
Рет қаралды 3,6 М.
Секрет фокусника! #shorts
00:15
Роман Magic
Рет қаралды 107 МЛН
Bend The Impossible Bar Win $1,000
00:57
Stokes Twins
Рет қаралды 48 МЛН
Transformers & Earth Connections
14:23
John Ward
Рет қаралды 223 М.
Understanding Inrush Current Measurements
12:13
Rohde Schwarz
Рет қаралды 6 М.
How Electrical Bushings Work (Power Engineering)
15:00
saVRee
Рет қаралды 68 М.
Transient Inrush Current in Transformer (26)
29:06
Learn Electrical Yourself
Рет қаралды 9 М.
Different parts of a Transformer and its function #transformer
5:00
Transformer core saturation and imbalance
12:01
Matthias random stuff
Рет қаралды 41 М.
Transformer Ratios and Taps
12:40
Dave Gordon
Рет қаралды 17 М.
All about Autotransformers
19:22
Zack Hartle
Рет қаралды 52 М.
Is it the volts or amps that kill?
20:50
styropyro
Рет қаралды 4,4 МЛН