Here is the updated link to the bonus content: www.haascnc.com/video/Video-Bonus-Content.html Thanks for watching!
@meganeura774 жыл бұрын
Where can you download those 3.0 macros? I have been all over the site, but it seems to have changed. Looking for 3.0 macros
@S0ulinth3machin3 Жыл бұрын
I got hung up on the battery thing for awhile. The old battery still read at least 3.62 on my multimeter. That's a serious PITA, if you can't tell. Thanks for this video, I would've been screwed without it!
@gford62732 жыл бұрын
This is an older video. At 7:10 Mark talks about manually checking probe but I cannot find any video like that. Help?
@OrcaMarine-l2m3 ай бұрын
It would be nice if the hasswips set up video included that you need to use the same tool number for your tool setter calibration tool as you use for your spindle probe
@JD977117 жыл бұрын
I need a video to calibrate the spindle probe using a ring clamped to table. Pre "NexGen" controls VF-9.
@gucio85pl4 жыл бұрын
Where is the downoad section? All i found was some manuals. And my VF-1 have some problem with tool probe (wireless, classic - 2007) calibration, Z axis (length) work just fine, but after that alarm pops up. And the calibrating macro is called like wired probe, not wireless.
@philhawtin5269 Жыл бұрын
where do the 9000 programs go on a classic control. Do i now have to live with seeing all those in my memory now? The memory on these classic controls is non existant, I would hate to have to run 100% of my programs off usb. Or do the 9000 programs hide like they currently are? Thanks for the help
@ralfg95005 жыл бұрын
I accidentally broke the stylus of my probe. Do I need to calibrate the probe after replacing the stylus/tips?
@Xocloud Жыл бұрын
Can I change the battery on the probe while it’s in the spindle? If I take it out and change batteries will I need to re calibrate my probe?
@markterryberry447711 күн бұрын
You do not have to recalibrate the probe if you change the batteries.
@anhtrung4872 жыл бұрын
My probe needle is broken, where can I buy it?
@nicholasostrem51975 жыл бұрын
Hello, @haasautomationinc I have a 2013 Mini Mill (purchased used) with wips and just got my calibration tool. When trying to calibrate the tool setter I get a 1093 probe fail. Im using the Maritool probe calibrator with a length of 4.000" and diameter of .3001. Any insight on why I'm getting this error.
@henmich5 жыл бұрын
Where can you download those 3.0 macros? I have been all over the site, but it seems to have changed.
@nicholasostrem51975 жыл бұрын
Any luck finding the 3.0 Macros?
@deannamatthews2017 Жыл бұрын
When I run the prob I get the message (sub program is missing) how do I get them back
@williamkring77618 жыл бұрын
I would Like to see the setup, install, and calibration of a renshaw probe on your Haas ST20Y.
@williamkring77618 жыл бұрын
Renshaw work probe.
@CMTheHollow5 жыл бұрын
On our Haas VF4 2004 model, I keep getting a 436 alarm (disk file not found) when trying to calibrate the tool work probe. Also my work probe does not beep when i touch it. Is all this a macro corruption issue?
@neilwatson24123 жыл бұрын
I have alarm 1086 on a proven programme ..Help please
@gauravcaleb33747 жыл бұрын
Sir, i working with haas 2008 vmc machine it shows alarm spindle not turning
@TheKrinky308 жыл бұрын
i love these tips and tricks! so this might be a super basic request but is there a rule of thumb or a formula for selecting your chuck pressure for a sl 30 haas lathe? i use both my hard jaws and soft jaws alot on a 10 inch kitagawa chuck.
@haasautomation8 жыл бұрын
For clamping force, it’s best to check with the chuck manufacturer. The part diameter, weight of the part, RPM, and even the size/weight of the jaws all play into this. If you have a Kitagawa B210, you can find more info here: kitagawa.com/chucks/open-center-power-chucks/b200-bt200-series/. One thing that most of us forget about is greasing our chucks with the right grease. We are supposed to grease the chuck nearly every day, and some people haven’t greased their chuck ever, and they have dangerously low clamp force because of it; see: kitagawa.com/chucks/chuck-accessories-chucks/chuck-grease-pro/. Also, as your RPM increases, your clamp force decreases (centrifugal force). If you have an LMC chuck, like a PC10, you can find their manual here: www.lmcworkholding.com/images/pdfs/pcOperatingManual.pdf. Because there are so many variables, we don’t typically give out suggested values. Hope this helps! -Mark, the Haas Tips of the Day
@angelonsah45567 жыл бұрын
Hello I just follow your video that me baucoup help but I have another problem that I'm tired a bit when I make the head of the machine it reculle I know it's not really what you can get me out of this problem
@atomkinder678 жыл бұрын
Is there any benefit to replacing our V2.8 probing routines with V3.0 for our 2012 VF6SS?
@haasautomation8 жыл бұрын
You are just fine with the V2.8 probing macros. Only small changes were made in the V3.0. These changes corrected a rounding issue that sometimes caused a 318 Z Over Travel Alarm on great big machines.
@atomkinder678 жыл бұрын
So what happens when we randomly lose some of our 9000 series programs? It happens often enough I put a backup of our parameters USB stick in the program directory where we load our part programs from.
@haasautomation8 жыл бұрын
Setting 23 9xxx PROGS EDIT LOCK should be set to ON, once you have reloaded those macros. With this on, your probing macros can’t be deleted or edited. A backup is always a great idea.
@atomkinder678 жыл бұрын
Haas Automation, Inc. Yes, we always run with that setting ON. We still have 9000 series probing macro programs disappear. It's very disconcerting.
@montetitus54352 жыл бұрын
What is wrong when I get a OTS start up failure error (1101 )
@michaelhailsonjr1972 жыл бұрын
Basically everything and anything, currently ready to go ham on this machine with a hammer.
@konradzieskeiii18962 жыл бұрын
Probably battery
@mnapster68267 жыл бұрын
I have a big problem with a hass renishaw, i broke that palpator and i changed after that ai trayed to calibration the renishaw, but when i put that circle to calibrate, I recive an error "OMP40 Needs Calibratio" exactly when I tray to calibrate him, please help me, I tray for 1 week to rezolv this problem. Thank you, sorry for my bad english, I hope you understand.
@haasautomation7 жыл бұрын
Hi m Napster - If you run into problems, when trying to calibrate your probe, it is best to Clear all of your Macro Variables first, and then go through the entire probe calibration process again (Tool Setter first, then Spindle Probe Length, then Spindle Probe Diameter). If you continue to have problems, your local Haas Factory Outlet can help you calibrate. Renishaw is always available with Tech support as well.
@mnapster68267 жыл бұрын
Thank you for support, I solved exactly what you said. Thanks for help!
@magnavtwin7504 жыл бұрын
y x probe alarm 1092 probe open this is the alarm I got trying to set the X & Y location with the probe
@harduslauwrens25018 жыл бұрын
You people from HAAS are the best. Do you have an official Swiss Partner? I Would love to become part of the HAAS family. I did my apprenticeship at the University of applied sciences here in Brugg AG, Switzerland and would love to try and apply for a job at your official distributer.
@haasautomation8 жыл бұрын
Hi Hardus. Thank you for the compliment, we hope you find all the TOD videos helpful! We do have distributors in Switzerland, you can find contact info for them on our website here: www.haascnc.com/finddealer.asp?Jquery%20Slider&Find%20Distributor%20Link&Contact%20Slider#gsc.tab=0. Hope this helps!
@tonyloosa95003 жыл бұрын
anyone else notice when teaching probe tool length, and comparing it to a facing tool that just ran (after the facing tool has been taught) that the probe length is off? I seem to have a constant .0007 inch difference between probe length and actual repeated final material removal (after facing).
@andrewspruyt11082 жыл бұрын
Tool pressure.
@tehfade538 жыл бұрын
We need a video on how to use the probe in the first place!
@haasautomation8 жыл бұрын
Absolutely. Here’s a how-to video we have up now: kzbin.info/www/bejne/opubkGyPfbFopMU. We’ll be doing some program-from-scratch probing videos soon, so stay tuned!
@nasihinnurismail65155 жыл бұрын
@@haasautomation i buy haas vf2 + 2axis tr160... my plan is use this machine on porting motorcycle cylinder head... what software perfect for this work, and can i probing other cylinder head porting and transfer to another head like centroid and rottler macbine do?
@gregbrown91388 жыл бұрын
Hello Mark, Great video. I have a Haas TM-2P VMC and I don't have the admin. rights to change the Macro variables of our machine. Do I have to call our local Haas distributor in Ontario,Canada or service center to re-calibrate our Renishaw (classic wirerless) probe) or can I do this myself?
@haasautomation8 жыл бұрын
Hello Greg, Sorry for the delay and thanks for the props on the video. Here are the button presses to access the Macro Variables on your machine, you shouldn't have any trouble reaching these areas in the control. 1st make sure the Memory Lock key is set to the OFF position and that Setting 120 is also set to OFF. Then go to CURRENT COMMANDS and page up until you reach the MACRO VARIABLES page. Then press the ORIGIN key, cursor down and select CLEAR ALL GLOBAL MACROS, press ENTER, and press Y to confirm. That should do it. Here is the link to the Haas DIY page where we have the WIPS Calibration procedure. diy.haascnc.com/procedures/wireless-intuitive-probe-system-wips-calibration
@MikeWearne8 жыл бұрын
If you have a probe problem, you have a PROBE LEM
@Владимир_Сабиров5 жыл бұрын
Ba-dum-tsss.
@LSDdreams8088 жыл бұрын
gotta love nfc files not found lol restart line
@brentneahring27977 жыл бұрын
maybe the probe wants to play Simon says: red blue green red blue green
@fernandov7347 жыл бұрын
I have a alarm! What's mean ? !! open probe !!
@anthonynorwood82907 жыл бұрын
Could mean you tried to turn probe on (G65 p9832) While it was already on. Or you tried to turn it on while probe is deflected are two reasons i know.