i saw the comment at other film saying RIP John。 so sad to hear that。 what a nice and helpful man.
@ZurnIndustries3 жыл бұрын
Appreciate your kind words. He's continually missed.
@mcroley5914 жыл бұрын
Great video and the instructor was very good!
@ZurnIndustries4 жыл бұрын
Glad you enjoyed it!
@loustanton44712 жыл бұрын
Diagnosis of a fouled #1 check valve was correct. After lifting the unit out found a piece of debris wedged in that valve. After removal of the debris the unit worked perfectly. This video is a keeper!
@doctoreeeveal4 жыл бұрын
Make sure to follow his instruction and flush the water through the disassembled valve. There can be debris in there that you can't see that can be causing the leak.
@ZurnIndustries4 жыл бұрын
Great input!
@harmagician15 жыл бұрын
Very clear and helpful. Thanks!
@CraigB801 Жыл бұрын
This helped me fix my issue, thank you!
@ajtheguy5 жыл бұрын
I found my 375 to leaks air in early November when I tried to low out the irrigation system. It turns out it gets colder early this year and the residual water frozen to icicles in the diaphragm, rendered the diaphragm cannot close itself. After clearing the I e debris, the air leak stopped.
@Jedi_Jed2 жыл бұрын
Thank you. This is what I’ve been needing to know. Usually I just check the vent diaphragm for debris. Pro Tip: Never ever buy the kind that doesn’t have replaceable components. I did during the supply shortage and now I’m out $400. Let me know if I’m wrong about that Zurn.
@dougwickland33037 ай бұрын
As I commented above, as an end user consumer it is next to impossible to find or get access to individual parts or a reasonably priced appropriate repair kit for the 375 back flow check value series (especially the 1" version) that has the one or two parts you might need. IMO, definitely not DIY consumer friendly.
@mattplants31136 жыл бұрын
That was great info! Thx
@michaelmiller84983 жыл бұрын
How are the check valves numbered on the 375 XL? 4 and 2 are mentioned but I am still unclear. Mike
@dougwickland33037 ай бұрын
I believe they are numbered sequentially, starting with the isolated individual valve located closest to the water supply inlet, and then moving to the cluster of 3 check valves (the first of them, closest to the supply inlet would be check valve number 2). Hope this helps.
@mariomarionetas44452 жыл бұрын
Great video and info! But tbh I Always get a repair kit and change everything anyway
@dougwickland33037 ай бұрын
Have you seen the prices of the available repair kits!!!? And too, it is next to impossible to find a reasonably priced repair kit to replace the springs on a 375 1" unit. Additionally, as a consumer you cannot locate individual parts; this is definitely not consumer friendly, IMO.
@MarioGarduño-s2e7 ай бұрын
@@dougwickland3303I said I carry trape kits with me , obviously I know ow the cost , I live in the city , not to hard to find up o 1” .
@moonchasestar3 жыл бұрын
I shut off thbe valve #2, the leakage is worse. The leakage is coming from the releaf valve diaphram itself not coming out the bottom opening. The leakage also comes out the small hole in the middle of the diaphram. If I use my finger to block it, the leakage is worse. If I have both valves shut off, the leakage remains but not as bad. I had both valves off for about 4 1/2 months and when I truned my valves on. this is what happening now. Lost water about 1 gallan for every 3 hours maybe. please help。 thanks. I have Zurn 975XL
@ZurnIndustries3 жыл бұрын
When experiencing leaks from the relief valve's vent port or air relief hole (Small "weep hole") you may need to repair the relief valve of the Model 975XL. A leak from the air relief hole will cause a loss in pressure on the diaphragm side of the releif valve, which is used as the closing pressure. Fixing that issue, which may be occuring from the relief valve o-ring, or relief vlave cover, could resolve any leaks from those areas. Please feel free to reach out to WilkinsCS@zurn.com for more assistance or troubleshoooting help.
@PLUMBdogg7 ай бұрын
love these vids.
@mohamedjuma36334 жыл бұрын
Does the relief valve leaks if the water is coming in to the building is leaking.
@ZurnIndustries4 жыл бұрын
The integral relief valves on Zurn Wilkins’ Backflow Prevention Assemblies protect against backflow occurrences by monitoring the pressure drop across the valve. Sudden pressure changes can cause some discharge. A small leak would not likely cause the valve to “leak” or discharge. A water meter is a good way to tell if there is a leak in the plumbing system.
@tahoet9194 Жыл бұрын
Thank you for the customer support! I have one of these in my sprinkler system and it was venting a LOT of water when I turned on my system. I watched this Zurn 975 diagnostic video and repair instructions (kzbin.info/www/bejne/maW8oKGEfNSaf6c) videos - with those videos most do-it-yourselfers will be able to repair one of these. Believe it or not mine had a piece of debris in valve 1 that was causing it to vent just like the videos said.