Wish I’d of found this Chanel a few years back , very good in depth fitting instructions , thank you young man … i will be watching the rest of your vids for sure 👍
@RichieRos3 ай бұрын
Welcome aboard! ✌️
@Kevmac3323 жыл бұрын
Your very welcome...we have to look out for one another...stay safe brother
@ilkerilker42483 жыл бұрын
thank you very very much ı search our sites in turkey but no body not explainin like you and you have many good ideas
@RichieRos3 жыл бұрын
Your very welcome! All the best will the build!
@Kevmac3323 жыл бұрын
Hi Richie, your going straight from your consumer unit 16 amps...you will blow your pcb...you must fit a spur unit...switch for good work practice and ideal for isolating at source for maintenance...make sure you put a 3 amp fuse in spur unit to reduce the ampage so not to blow your pcb. If you read your manufacturer's instructions I'm sure it will explain what I'm saying for sure 👍
@RichieRos3 жыл бұрын
Thanks Kevin :)
@1smct3 жыл бұрын
Using that water pump you need a one way valve in the cold water feed as per the instructions also the red connector is a vent and the drain tap has a built in pressure relief valve
@RichieRos3 жыл бұрын
Thanks for your advice! Yes I have a one way valve in the cold water feed! I just didn’t mention it for the water heater install. I will be doing a plumbing video where I will explain my plumbing setup :)
@Kevmac3323 жыл бұрын
Hi Richie, hope you don't mind but I have some concerns for you... your boiler should be on a none combustible material ie: checker plate under your boiler...also you put the flue together with plumbers mate...I recommend you use high temperature sealant ie: tubes like silicone that can withstand high temperature...forms a fantastic seal you can get off ebay for around €8. I hope you don't mind me saying... I'm a heating engineer. Regards and stay safe brother 💪
@RichieRos3 жыл бұрын
Thanks a million for the advice Kevin! Good idea, I can slide a checker plate under the boiler and I'll get a high temperature sealant for the cowl extension. :) Thanks again.
@Kevmac3323 жыл бұрын
Hi Richie, sorry I just noticed your electrical connection/junction box...I might have missed it but you need to change that to a switch spur and fit a 3 amp fuse...hope you don't mind my hopefully constructive comments...its not meant to be criticism only trying to hear 👍
@Kevmac3323 жыл бұрын
Help
@RichieRos3 жыл бұрын
No worries Kevin thanks for the help/feedback, much appreciated. I'm learning as I go :) I'm confused now because I actually discussed that connection/junction box with an electrician. I specifically remember asking him do I need a fuse at that connection and he said no just use a connector block.
@tospicy4ya3 жыл бұрын
Did u look into the whale heater ? I think it’s half the price of truma
@RichieRos3 жыл бұрын
Nope, never heard of it! The reason I decided on the Truma ultra store water heater is because I can run it off gas for off grid and also hook up 240v
@davopottso12 ай бұрын
Hi, what type and size water pump are you using?
@RichieRos2 ай бұрын
Shurflo 30PSI
@paul910703 жыл бұрын
Hey pal hope your well. Just wanted to know the height of the platform you have the heater sat on. Keep up the good work.
@RichieRos3 жыл бұрын
Sorry for the late reply! I Forget the exact height of the platform. The height of the platform for the water heater to rest on, should be high enough for the water heater coil to clear the trim on the outside of the van. Hope that helps!
@amacmedia32213 жыл бұрын
Hi Ritchie, what connections are needed to fit the 8mm copper pipe to the Truma water heater after the manifold?