Tutorials: How to change the range and unit for volume flow for KROHNE flowmeter.

  Рет қаралды 33,163

Team Obias Vlogs

Team Obias Vlogs

Күн бұрын

Пікірлер: 35
@StartUpEntrepreneurPh
@StartUpEntrepreneurPh 4 жыл бұрын
Very informative video. Such an intellectual creature. From your real friend
@hachebarra
@hachebarra 4 жыл бұрын
The tutorial is very illustrative. Thank you so much!
@teamobiasvlogs495
@teamobiasvlogs495 4 жыл бұрын
Wow! Thanks! I hope my video was able to help somehow.
@zakirhussain-wi3vu
@zakirhussain-wi3vu 3 жыл бұрын
Very good explanation
@cyruskurtmaurillo4748
@cyruskurtmaurillo4748 2 жыл бұрын
Thank you for this video it is very helpful.
@cyruskurtmaurillo4748
@cyruskurtmaurillo4748 2 жыл бұрын
Sir I changed the unit from kg to liter but the value is too low. Which parameter should I go to change the type of process like fuel oil diesel.
@robhunter6772
@robhunter6772 2 жыл бұрын
I'm guessing as you change the range then the current output changes ??
@mintsanesta
@mintsanesta 11 ай бұрын
hi obias, i would like to use khone optiflux 6050 to control a tank filling of 2700L or 3400L depending on the process on the same tank, thank you very much for your videos i ve learned a lot
@thulanigregory9382
@thulanigregory9382 3 жыл бұрын
I have a problem, there are two kronhe mag flows in my plant, the totalizer value increases without having flow....?why..?
@hassanhussien5600
@hassanhussien5600 2 жыл бұрын
I have a problem with a device, that it does not read until the opening rate of the control valve is 25%? What is the solution?
@olivertria3602
@olivertria3602 3 жыл бұрын
sir! krohne 2300c display 1 error " over range" always shown.while in display 2 is correct reading in Analog input 1. it is foundation fieldbus. can y u help me sir.. thank you for sharing your vedio
@moklism6378
@moklism6378 4 жыл бұрын
Thanks for the video, it was very helpful. Can the steam meter be set to display total kg of steam passing through the meter rather than kg/h? I have the meter set to pulse for 1 kg of steam and require the display to match the pulse output.
@teamobiasvlogs495
@teamobiasvlogs495 4 жыл бұрын
Hi! You have the Optisonic unit? Correct?
@moklism6378
@moklism6378 4 жыл бұрын
@@teamobiasvlogs495 Hello and thanks for relying! It's a Optiswirl 4200. I may have found what I'm looking for in the manual. I think I need to change the display measurement from 'Mass flow' to 'Mass'. Setup>Display>Meas. Page>C5.3.2 Measurement 1 Line>Mass.
@teamobiasvlogs495
@teamobiasvlogs495 4 жыл бұрын
@@moklism6378 no problem. just hit me up here if you have questions. please do subscribe :p
@muhammadimran1266
@muhammadimran1266 11 ай бұрын
Sir can you share me vedio link for loop test and calibration of krohne optiflex 2200c level transmitter
@bw26brw86
@bw26brw86 11 ай бұрын
Thank you for English 🎉🎉
@MuhammadAslam-ig3my
@MuhammadAslam-ig3my 3 жыл бұрын
Wonderful
@hiwaali
@hiwaali 2 жыл бұрын
How to return the counter in flow meter korhone
@soheibtaibi8976
@soheibtaibi8976 3 ай бұрын
we need a calibration video please
@AbdullahEstano
@AbdullahEstano Жыл бұрын
Assalamuwalaikom sir us ko lang po pwedi ilagay sa online flow meter but showing no data
@anandyadav4603
@anandyadav4603 2 жыл бұрын
Thanks
@pinalmaturkar3219
@pinalmaturkar3219 3 жыл бұрын
Can we set kg/hr unit??
@teamobiasvlogs495
@teamobiasvlogs495 3 жыл бұрын
Yes its possible!
@nemesis8010
@nemesis8010 3 жыл бұрын
I need information of Ifc 300, in spanish please
@bintucbabu7110
@bintucbabu7110 4 жыл бұрын
Bro...Genii DP1620 not connect
@bintucbabu7110
@bintucbabu7110 4 жыл бұрын
Any suggestion
@teamobiasvlogs495
@teamobiasvlogs495 4 жыл бұрын
do you have the corrct dtm? for which model
@arun4846
@arun4846 2 жыл бұрын
👍
@ericoduro7734
@ericoduro7734 Жыл бұрын
Ours in our company is always showing installation and nothing
@RoseroL
@RoseroL 3 жыл бұрын
it doesn't match what I see in the MI for the MFC400
@sijukannur
@sijukannur 4 жыл бұрын
Sir please give me krohne optimass service password
@teamobiasvlogs495
@teamobiasvlogs495 4 жыл бұрын
sorry. this is not something we give... only for service engineers of krohne. ✌
@sijukannur
@sijukannur 4 жыл бұрын
@@teamobiasvlogs495 how can I change max pulse rate?
Tutorials: #Opticheck Version Update (Manual) #KROHNE #Opticheck
2:48
Team Obias Vlogs
Рет қаралды 1,9 М.
Caleb Pressley Shows TSA How It’s Done
0:28
Barstool Sports
Рет қаралды 60 МЛН
Wednesday VS Enid: Who is The Best Mommy? #shorts
0:14
Troom Oki Toki
Рет қаралды 50 МЛН
KROHNE IFC300 Magnetic Flow Meter Setting
5:05
MUDASAR MUNIR
Рет қаралды 1,8 М.
Krohne Optiflux IFC300 | Programming: Totalizer Setup
2:58
SlaterControls
Рет қаралды 21 М.
DP Flow Transmitter Testing and Recalibration
8:24
RealPars
Рет қаралды 182 М.