Heat Pump 11 Gauges

  Рет қаралды 12,726

Love2HVAC with Ty Branaman

Love2HVAC with Ty Branaman

Күн бұрын

Пікірлер: 19
@chesstime356
@chesstime356 8 ай бұрын
As always I like your videos I do watch them over and over
@unabridgeddick6645
@unabridgeddick6645 3 ай бұрын
The small hands 🤣🤣🤣🤣. Another fantastic source of knowledge. Thank you sir.
@Studentofhvac
@Studentofhvac Жыл бұрын
Probably one of the best explanations out there.
@love2hvac
@love2hvac Жыл бұрын
Thank you! Your art work makes it so much better!
@Raphael_NYC
@Raphael_NYC Жыл бұрын
Excellent analysis and explanation. Thank you. raphael nyc
@repairitdontwreckit4257
@repairitdontwreckit4257 11 ай бұрын
Great video. Thanks.
@SupremeRuleroftheWorld
@SupremeRuleroftheWorld Жыл бұрын
now if you really want to have a fun time hooking up gauges you should try a mitsubishi city VRF unit, those can do heating and cooling at the same time over just 2 pipes going to the distribution box. that system is a real mindbender to wrap your head around. it transports both hot gas and liquid refigerant in 1 pipe.
@coldfinger459sub0
@coldfinger459sub0 Жыл бұрын
That’s why you do not use refrigerant gauges. Just a software on your computer and the units have all the pressure transducer’s and thermocouple sensors right on your screen telling you everything..
@brianmcdermott2430
@brianmcdermott2430 Жыл бұрын
Great info. as always. Thank you Ty.
@HVAC_Tips_Tricks_Calcs
@HVAC_Tips_Tricks_Calcs Жыл бұрын
Awesome video. Love the 'pointers'. Knowing you’re a perfectionist, your graph has a typo in the upper right corner at the 14:46 mark. Condenser is spelled incorrectly. And in the next graphic, 'Always' is spelled incorrectly.
@love2hvac
@love2hvac Жыл бұрын
I'm certainly no perfectionist. My very very very bad spelling is why I try to avoid using word on the screen.
@WobblingHobGoblin
@WobblingHobGoblin Жыл бұрын
Good Video. However where I live an work all of our heat pumps are inverter driven, and use EEVs, not TXVs. So using Super Heat and Sub Cooling is not an option for diagnosing. Would love to see an in depth video on inverter mini splits. Cheers
@Boxmediaphile
@Boxmediaphile 5 ай бұрын
Are you sure about Superheat in heat mode because heating doesn’t need the same amount of refrigerant as it does in cooling
@Hvacr123
@Hvacr123 Жыл бұрын
Hey Teacher TY how are doing ? Will we have a class about 407C ?🤓
@love2hvac
@love2hvac Жыл бұрын
Maybe
@Hvacr123
@Hvacr123 Жыл бұрын
@@love2hvac I am ready 🤓
@heatingairservices8708
@heatingairservices8708 10 ай бұрын
awesome tutorial Thanks ..seems to me someone needs to invent an an True HP Gage set ...That contain a 3 prob set or gauge set w/ 3 pressure ports & tempt probs / 4 with charging hose to cover all 3 ports simultaneously anyone concur ?? lol
@gamking7987
@gamking7987 Жыл бұрын
You look like Optimus prime 😂
@love2hvac
@love2hvac Жыл бұрын
“Freedom is the right of all sentient beings” ― Optimus Prime. ...
31 year old Heat Pump Copeland scroll cut open & inspected.
6:49
Love2HVAC with Ty Branaman
Рет қаралды 10 М.
Heat Pump 03 Reversing valve
21:04
Love2HVAC with Ty Branaman
Рет қаралды 35 М.
Twin Telepathy Challenge!
00:23
Stokes Twins
Рет қаралды 123 МЛН
Heat Pump 12 Hight Pressure trips only in Heating
12:51
Love2HVAC with Ty Branaman
Рет қаралды 10 М.
Crucial Knowledge To Heat Pump Troubleshooting
14:15
Jersey Mike HVAC
Рет қаралды 44 М.
R-22 and R-410A Operating Pressures on Air Conditioners! Checking the Charge!
7:41
Heat pump 04 Accumulator & Muffler
7:25
Love2HVAC with Ty Branaman
Рет қаралды 22 М.
Checking the Charge of Heat Pump or AC in Winter Low Outdoor Temps
11:30
AC Service Tech LLC
Рет қаралды 133 М.
How To Check Superheat & Subcooling On An HVAC System
16:03
The DIY HVAC Guy
Рет қаралды 117 М.
Heat Pump Freezing Up in Apartment Building
23:19
Taddy Digest
Рет қаралды 8 М.
HVAC 109 Example, charging a low system
11:59
Love2HVAC with Ty Branaman
Рет қаралды 23 М.
Heat Pump No Heating Simple Fix
15:18
John Israel HVAC
Рет қаралды 121 М.