Sir, as per AWS D1.1 section 6 part F 6.22.7.1 transducer frequency SHALL be between 2 to 2.5 MHz and under 6.22.7.1 the transducer dimensions SHALL be 15mm to 25mm in width and 15mm to 20mm in height....
@karansathwara12286 жыл бұрын
If possible than upload a video of Weld UT having defects and tell how to identify nature of defect(i.e LOF, Porosity,Slag, Lop
@eswararaob66716 жыл бұрын
What is the purpose of 3mm width and R25 curve
@dudeabc1008 жыл бұрын
Dude, u need to verify if the probe is really refracting 70 degrees of shear waves. Since ur doing this full video right from the scratch and hence its advised that u verify the angle first before you do ur velocity and wedge delay calibration
@medjallouli92447 жыл бұрын
please the position of hole in the calibration v1??? , merci
@arifbugga71867 жыл бұрын
Telling everything wrong.first verify probe angle , probe infex then varify beam path length from two echoes
@mdkamranansari57815 жыл бұрын
Sir hindi me audio dubbed kijiye plsss for better understand..