AS per my consideration, the hydrostatic pressure will simultaneously act on all walls. We have to add a combined load for this to take effect. Also wave pressure due to EQ has not been considered. We also have to ascertain that earth pressure dry and saturated/submerged does not give higher moments and stresses as compared to water pressure from inside only. such a large tank needs cover at top with manhole. The design is incomplete with these considerations. Please elaborate on these issues as well.
@venkateshs69297 ай бұрын
Actually that is not hydrostatic pressure. It is water pressure on side walls defined separatly..
@bibekdhakal1094Ай бұрын
Thank you very much for the video. It helped me a lot
@civilengineeringbyshravan9596Ай бұрын
Glad it helped
@kunal611904 жыл бұрын
Sir ji, very well explained. But the UGT side walls should be designed for empty condition with saturated soil pressure and base slab for empty condition for upward soil pressure. Please add load cases as well. Thank you!
@selvikarthik31013 жыл бұрын
Yes. Do you have any reference vel to help design UGT with critical condition you mentioned . If you have reference please share the link. Thank you so much
@NOW-TECJ2 жыл бұрын
True
@swagatomajumder66644 жыл бұрын
What about the load due to soil? Liquid retaining structures should confirm to IS 3370 and IS 1893 part 2.... analysis is incomplete without these
@nikhilwakade16735 жыл бұрын
very useful video, thanks mate.
@muhammedlamyp.j98605 жыл бұрын
What about the load due to soil ... When tank is empty
@shubhamdubey74482 жыл бұрын
Very informative
@Merkur_Konusuyor5 жыл бұрын
very handy video, thanks mate. Is it possible to post more videos about mesh?
@civilengineeringbyshravan95965 жыл бұрын
Definitely I will
@muhammadiqbalmulyatarmidzi17794 жыл бұрын
what about in staad pro Advanced connect edition, because there is no surface option
@etishasingh_3 жыл бұрын
What are the load combinations you used here?
@civilengineeringbyshravan95963 жыл бұрын
based on water pressure
@djul2373 жыл бұрын
hi idol, is this applicable to rectangular swimming pool design analysis?
@halamohamedabdollah77992 жыл бұрын
How was the slack on the sides of the tank calculated? Please clarify
@rinchenjigsumdorji26684 жыл бұрын
How did you calculate the water pressure and soil pressure values. Could you please explain in details
@halamohamedabdollah77992 жыл бұрын
I also want to know how or how to calculate. Did you get any information? Please reply
@structuralengineer37874 жыл бұрын
To look about reinforcement sizes pls can you provide details link to further refer?
@ahmaddawood5422 жыл бұрын
RCC Stands for?
@varaprasadmaragani58934 жыл бұрын
Plz explain about reinforcement details clearly at out put
@civilengineeringbyshravan95964 жыл бұрын
Please check in output file Brother
@bheemanisravankumar10283 жыл бұрын
How to Loads calculation ? How to select the quadrintal ?
@bheemanisravankumar10283 жыл бұрын
How to show clear steel alignment and reinforcement details for this structure??
@nereofibonacci4 жыл бұрын
Muchas gracias
@praveenaprasan24463 жыл бұрын
At sides of water tank only hydrostatic pressure is considered Why soil pressure is not considering in sides Also in suface load only soil pressure is considered why hydrostatic pressure is not considering here
@civilengineeringbyshravan95963 жыл бұрын
The load is applied in gravity direction only for water so for that reason we need to take pressure in bottom than sides
@praveenaprasan24463 жыл бұрын
@@civilengineeringbyshravan9596 What all changes happen in the loading condition if the tank is empty sir??
@praveenaprasan24463 жыл бұрын
@@civilengineeringbyshravan9596 while designing didn't we consider both empty as well as full ?
@naveenkumar-wg4ut3 жыл бұрын
sir please tell me how can we calculate wp&sp
@subashchandran10503 жыл бұрын
Which software
@yogeshp33663 жыл бұрын
what about dead load its not assigned in this video
@civilengineeringbyshravan95963 жыл бұрын
what i will check it once
@yogeshp33663 жыл бұрын
@@civilengineeringbyshravan9596 ok sir
@Happyhappy-th9sc2 жыл бұрын
Why did u consider pressure as 30and 40
@Happyhappy-th9sc2 жыл бұрын
Is there any caluculations or is these assumed values
@chetansonkar36013 жыл бұрын
how to use this design results it very complicated
@civilengineeringbyshravan95963 жыл бұрын
Which part?
@varaprasadmaragani58934 жыл бұрын
And how to draw in AutoCAD that details
@thangaraj45394 жыл бұрын
Ur teaching tooo...... Faster
@civilengineeringbyshravan95964 жыл бұрын
Sorry for that inconvenience
@hamidara4860 Жыл бұрын
sorry but your modelisation is false
@civilengineeringbyshravan9596 Жыл бұрын
Yes as per my assumption failed we have to modify specifications