You are doing very good work by spreading knowledge.
@TanweerAhmed9 ай бұрын
Thanks a lot for appreciating
@Uzairkhan-ly7fv9 ай бұрын
Sir your video is very knowledgeable. Allah always happy you to you
@TanweerAhmed9 ай бұрын
JazakaAllah khairan
@wazidaman75979 ай бұрын
Massallah Sir Your Video helps me too much ❤
@TanweerAhmed9 ай бұрын
JazakaAllah
@muhammadyaseen-w9o9 ай бұрын
Appreciated your struggles
@TanweerAhmed9 ай бұрын
Thank you
@hashirinarabworld9 ай бұрын
Good Work
@TanweerAhmed9 ай бұрын
Thanks
@Sadiqgul-s5p9 ай бұрын
GOOD JOB KEEP IT
@TanweerAhmed9 ай бұрын
Thank you
@rizwanansari-wd2uq9 ай бұрын
Nice explain
@TanweerAhmed9 ай бұрын
Thank you
@chetanmhatre87809 ай бұрын
Dear sir, plz make video on positive and negative isolation room calculation
@TanweerAhmed9 ай бұрын
Will try
@Sadiqgul-s5p9 ай бұрын
GRATE
@TanweerAhmed9 ай бұрын
Thanks
@asjadhameed41799 ай бұрын
good
@TanweerAhmed9 ай бұрын
Thanks
@adilsgamingchannel79078 ай бұрын
make a detailed video on how to calculate wall and glass u value
@TanweerAhmed8 ай бұрын
I suggested to follow hap software for this u valve
@imranlion19969 ай бұрын
Pakistan ma aise ventilation system kesa bana skty hen
@TanweerAhmed9 ай бұрын
پاکستان میں ایسے وینٹیلیشن سسٹم بنتے بھی ہے اور لگائے بھی جاتے ہیں۔
@imranlion19969 ай бұрын
@@TanweerAhmed Pakistan ma window se exhaust fan hote hen ziada ma Jo Woh bare steel k hote hen jesa USA wagera ma hote hen
@star_ultron9 ай бұрын
A/s Sir..... According to NFPA 13 Ordinary group 2 hazard in that 25Dia pipe we use 2 no's sprinkler Can I use 4no's sprinkler in 25 dia....there is any possibility for this.... Btw Jazakallah aap axhha kam kr rhe ho❤
@TanweerAhmed9 ай бұрын
I don't recommend to bypass the standard because at a time these 4 sprinklers activate then less flow of water will be there in each sprinkler which is violation of standard requirements.
@star_ultron9 ай бұрын
@@TanweerAhmed Sukriya Sir, Can I bypass standard through hydraulic calculation Like can I calculate overall hydraulic calculation for the FPS system and bypass the standard.. Is it possible or not sir, Or According to the standard if I'm going for installation there is a need to calculate hydraulic calculation ? Please sir, reply to this I'm so confused about this.... Jajakallah khair
@star_ultron9 ай бұрын
@@TanweerAhmed Sir Are you providing an online training course? If yes please let me know how to join
@TanweerAhmed9 ай бұрын
@@star_ultron As per NFPA 13: The water demand requirements shall be determined by either the pipe schedule method or the hydraulic calculation method. The minimum water supply requirements for light and ordinary hazard occupancies protected by systems with pipe sized according to the pipe schedules method and for extra hazard occupancies shall be based on the hydraulic calculation methods.
@TanweerAhmed9 ай бұрын
@@star_ultron Sorry, I don't offer online training course except for KZbin videos
@hashirinarabworld9 ай бұрын
پھر اسلاں لیکم ، اسلاں لیکم نہیں میرے بھائی اسلام علیکم صحیح طرح سلام کریں نہیں تو نہ کرو
@TanweerAhmed9 ай бұрын
I think you have problem regarding understanding اسلام علیکم or something else. I don't like to criticise on this issue anymore. Otherwise I will take action to block you forever.