Hi, excellent video! There is a way to estimate how depth the vt pump "carry" the mass of water? If I have the pump on a lake, how depth the vt pump suction the water?
@nonono11082 жыл бұрын
how to change the mechanical seal? can it be done with out lifting the pump assembly?
@gopeshvijay87253 жыл бұрын
What is the reason of shaft shear from head shaft or stuff fixing at shaft sleeve? (While no vibration and no current daviation)
@myndengineeringacademy58733 жыл бұрын
shaft shear from head shaft because while designing pump considering following aspect 1. Easy to assemble 2. easy to replace 3. cost of maintenance or spare part in vertical turbine pump mainly chance to break "head shaft or top shaft " .theare are many factors responsible for it such as axial thrust, back pressure, initial torque... etc. sleeve main function is protecting to shaft from wear & tear.
@nurdinmsangi73513 жыл бұрын
hellow there,i have a vertical turbine pump with 9 diffuser,i want to increase a flow rate from 136m3/h to 200m3/h.what can i do to archieve my goal.i seek for help please
@myndengineeringacademy58733 жыл бұрын
Hello, Practically we can't rise flow. We rise head by changing impeller dia but for flow there is no obtion. Only one option is change pump model with respective your requirement
@nurdinmsangi73513 жыл бұрын
thank you @@myndengineeringacademy5873
@nurdinmsangi73513 жыл бұрын
sorry when you say to change pump model what does it mean?.it means to change the overall pump or?explain sorry@@myndengineeringacademy5873
@nurdinmsangi73513 жыл бұрын
also i want to know how number of diffuser affect the flow rate?.@@myndengineeringacademy5873
@myndengineeringacademy58733 жыл бұрын
Number of diffuser can't affect on the flow rate its affect only on head. Suppose single diffuser genrate 25 mtr head at 100 m3/hr then three diffuser genrate 75 mtr head at same flow means 100 m3/hr. So means that you can vary only head can't change flow rate.
@harishkaushik72383 жыл бұрын
Kya 6" bore m lag jayega aur kitna kharcha hoga depth 60 foot
@brijmohansoni2234 Жыл бұрын
I am pumping acid 1.8 sp. gr. rather than water then what parameters will change and what will remain unchanged?
@theryanpaige Жыл бұрын
You'll want to use a good mechanical seal to avoid any fluid leaking at the discharge head. The SG will require you to double the HP (compared to a water pump) and use a corrosion or hostile duty motor. Also important is to choose materials of construction that can withstand corrosion from the acid.
@sammed5632 жыл бұрын
Good explanation sir . How can posses the installation manual of BHN oil cooled VT pump . Thank you .