Vertical Turbine Pump || VT Pump || Vertical Pump...... Installation Information

  Рет қаралды 20,069

My Nd Engineering Academy

My Nd Engineering Academy

Күн бұрын

Пікірлер: 15
@gustavoarturo8578
@gustavoarturo8578 9 ай бұрын
Hi, excellent video! There is a way to estimate how depth the vt pump "carry" the mass of water? If I have the pump on a lake, how depth the vt pump suction the water?
@nonono1108
@nonono1108 2 жыл бұрын
how to change the mechanical seal? can it be done with out lifting the pump assembly?
@gopeshvijay8725
@gopeshvijay8725 3 жыл бұрын
What is the reason of shaft shear from head shaft or stuff fixing at shaft sleeve? (While no vibration and no current daviation)
@myndengineeringacademy5873
@myndengineeringacademy5873 3 жыл бұрын
shaft shear from head shaft because while designing pump considering following aspect 1. Easy to assemble 2. easy to replace 3. cost of maintenance or spare part in vertical turbine pump mainly chance to break "head shaft or top shaft " .theare are many factors responsible for it such as axial thrust, back pressure, initial torque... etc. sleeve main function is protecting to shaft from wear & tear.
@nurdinmsangi7351
@nurdinmsangi7351 3 жыл бұрын
hellow there,i have a vertical turbine pump with 9 diffuser,i want to increase a flow rate from 136m3/h to 200m3/h.what can i do to archieve my goal.i seek for help please
@myndengineeringacademy5873
@myndengineeringacademy5873 3 жыл бұрын
Hello, Practically we can't rise flow. We rise head by changing impeller dia but for flow there is no obtion. Only one option is change pump model with respective your requirement
@nurdinmsangi7351
@nurdinmsangi7351 3 жыл бұрын
thank you @@myndengineeringacademy5873
@nurdinmsangi7351
@nurdinmsangi7351 3 жыл бұрын
sorry when you say to change pump model what does it mean?.it means to change the overall pump or?explain sorry@@myndengineeringacademy5873
@nurdinmsangi7351
@nurdinmsangi7351 3 жыл бұрын
also i want to know how number of diffuser affect the flow rate?.@@myndengineeringacademy5873
@myndengineeringacademy5873
@myndengineeringacademy5873 3 жыл бұрын
Number of diffuser can't affect on the flow rate its affect only on head. Suppose single diffuser genrate 25 mtr head at 100 m3/hr then three diffuser genrate 75 mtr head at same flow means 100 m3/hr. So means that you can vary only head can't change flow rate.
@harishkaushik7238
@harishkaushik7238 3 жыл бұрын
Kya 6" bore m lag jayega aur kitna kharcha hoga depth 60 foot
@brijmohansoni2234
@brijmohansoni2234 Жыл бұрын
I am pumping acid 1.8 sp. gr. rather than water then what parameters will change and what will remain unchanged?
@theryanpaige
@theryanpaige Жыл бұрын
You'll want to use a good mechanical seal to avoid any fluid leaking at the discharge head. The SG will require you to double the HP (compared to a water pump) and use a corrosion or hostile duty motor. Also important is to choose materials of construction that can withstand corrosion from the acid.
@sammed563
@sammed563 2 жыл бұрын
Good explanation sir . How can posses the installation manual of BHN oil cooled VT pump . Thank you .
@osa_ye
@osa_ye 3 ай бұрын
Can i contact you
Vertical Turbine Pump  || व्हर्टिकल टरबाइन पंप
19:50
Introduction to Vertical Turbines Pumps: Part 1
12:53
Xylem Industrial Solutions
Рет қаралды 17 М.
Introduction to Vertical Turbines Pumps: Part 3
17:43
Xylem Industrial Solutions
Рет қаралды 3,9 М.
Peerless Pump Vertical Turbine Pump Assembly. Part 1
16:10
Michael Grant
Рет қаралды 8 М.
Pump Chart Basics Explained - Pump curve HVACR
13:05
The Engineering Mindset
Рет қаралды 1,8 МЛН
Vertical Turbine Pump Installation Training Video
6:09
Precision Pumping Systems
Рет қаралды 10 М.
Short Course 12. Vertical Pumps (VS4/5, VS6, VS7).
53:03
Ruhrpumpen Group
Рет қаралды 5 М.
Horizontal Split Case Pump Demonstration (Animation)
12:03
MrityunjayaCreations
Рет қаралды 97 М.
Restoring a Bowl Assembly Without Buying a New Pump
5:34
Pumps Motors & Controls
Рет қаралды 3,4 М.
Comparison between Vertical Turbine Pump and Centrifugal pump
5:19
SUPER FAST STUDY & Experiment
Рет қаралды 9 М.
Do Pumps Create Pressure or Flow?
10:38
Practical Engineering
Рет қаралды 1,4 МЛН