Introduction to the Orion XS; a lightweight non-isolated DC/DC charger

  Рет қаралды 27,464

Victron Energy

Victron Energy

Күн бұрын

Пікірлер: 118
@sutliffgnassi9925
@sutliffgnassi9925 2 ай бұрын
Can't wait for a 24V to 24V non-isolated version!!!
@johannesboonstra6917
@johannesboonstra6917 2 ай бұрын
Almost there, its going to be the XS 1400 (watt) and input and output voltages can be selected 12/24V)
@AlexV89
@AlexV89 27 күн бұрын
@@johannesboonstra6917 Very much looking forward to this as well - any update on the timeline?
@johannesboonstra6917
@johannesboonstra6917 25 күн бұрын
@@AlexV89 Q2
@AlexV89
@AlexV89 25 күн бұрын
@@johannesboonstra6917 thanks for the update
@Bigorse91
@Bigorse91 3 ай бұрын
Can't wait for the isolated version
@johannesboonstra6917
@johannesboonstra6917 25 күн бұрын
really need isolation? that model is far away yet I ama afraid
@fredturk6447
@fredturk6447 3 ай бұрын
Brilliant. All the required features! At 98.5% efficiency only dissipating 10 watts at full output and not wasting energy.
@ray32825
@ray32825 9 күн бұрын
If I install a heat sink in the back, that should help it run even cooler.
@rhoderzau
@rhoderzau 3 ай бұрын
Still looking forward to the 12 - 24v version
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 3 ай бұрын
On its way, we expect these end of the year!.
@krikkenstein
@krikkenstein 3 ай бұрын
I second that! Please release quickly! 🙏🏻
@doughdfzr
@doughdfzr 3 ай бұрын
Yup lots of us waiting!
@kymschubert5042
@kymschubert5042 3 ай бұрын
Yes. 48V is the future…
@SavageBeastChronicles
@SavageBeastChronicles 3 ай бұрын
Wating for the 12-24V too ! Thanks.
@TRAVISGOLDIE
@TRAVISGOLDIE 3 ай бұрын
Im hanging out for the 24 and 48v versions for so many installs i have planned
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 3 ай бұрын
working hard on them !
@krikkenstein
@krikkenstein 3 ай бұрын
@@JohannesBoonstra-ol2nz What to expect? 12/24-25? Or is there something more powerful coming?
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 3 ай бұрын
@@krikkenstein yes and yes, a more powerful as well.
@drc6940
@drc6940 3 ай бұрын
You're going to have to go with Sterling Power's products for now. I have a 12v to 48v, 750 watt converter in my camper and it seems decent so far.
@TRAVISGOLDIE
@TRAVISGOLDIE 3 ай бұрын
@@drc6940 no im happy to wait for these
@niconahla
@niconahla 3 ай бұрын
On a vraiment hâte que la version 24/24 arrive enfin 👍
@gergodrabik6208
@gergodrabik6208 3 ай бұрын
Gamechanger already I have already installed 3. Genius. Also I wait to have a littlebit more VRM implementation. Should have its on tile for example :)
@13thdukeofwybourne69
@13thdukeofwybourne69 3 ай бұрын
This is OK, but I'm waiting for the 12-24v Orion XS please!
@Slay3rOne
@Slay3rOne 3 ай бұрын
I seem to remember reading somewhere there will be a version with selectable voltage for 12-24V maybe 48V, or are those separate units? My house is on 48V, desperately waiting for something to bridge the gap between 48V and 12/24V systems. Looking forward to it! Also bidirectional is definitely something I'm eagerly waiting for, that will be a gamechanger!
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 3 ай бұрын
yes, these unit will come (in time).
@robertstuckle6198
@robertstuckle6198 3 ай бұрын
Hello, did you think about a Orion with alternator temperature monitoring? What's with bi-directional charging and VE. Bus Connection? Best regards Robert
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 3 ай бұрын
yes, these idea's are on the list already!
@robertstuckle6198
@robertstuckle6198 3 ай бұрын
Thank you. Sound's good.
@johnharding123john
@johnharding123john 2 ай бұрын
When is the 48-12v 50A coming out really looking forward to it!
@outbackelectrical7707
@outbackelectrical7707 3 ай бұрын
Will a 48V version be made available ? would be awesome for our wind turbine and hydro DC-DC conversion side!
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 3 ай бұрын
yes,
@UKsystems
@UKsystems 2 ай бұрын
Both of these need very specialist charge controllers that keep a constant load. This may not be the best option.
@outbackelectrical7707
@outbackelectrical7707 2 ай бұрын
@@UKsystems False, The turbines controller is built in and the existing Orions work fine.
@UKsystems
@UKsystems 2 ай бұрын
@@outbackelectrical7707 actually very few turbines have a controller built in so in your case it may work but it’s definitely worth knowing that a lot of them do not like a load that could just switch off suddenly
@UmbrellaProject6790
@UmbrellaProject6790 3 ай бұрын
Habe ich schon das Teil ist super Das Beste ist dass man die Zeit verkürzen oder verlängern kann zwischen Bulk und Absorption bei den Ladereglern Wenn der Wechselrichter wegfährt schalten alle Laderegler auf Blau/Bulk
@wanderingzythophile9083
@wanderingzythophile9083 3 ай бұрын
I'm curious, why not build in the feature where you can reverse the current flow, and push power from a leisure system into the starter battery?
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 3 ай бұрын
theoraticly everything I possible, but we take it step by step and will get there.
@wanderingzythophile9083
@wanderingzythophile9083 3 ай бұрын
@@JohannesBoonstra-ol2nz It's a shame you folks didn't roll that in with this revision!
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 3 ай бұрын
@@wanderingzythophile9083 Haha , I know but things ar not as easy as writing it down on a wish list. It's hardware plus software. At development it's always about priorities, and this one was just not high enough on the list.
@UKsystems
@UKsystems 2 ай бұрын
In most cases that is pointless also if you really need to keep the starter battery charged it may be worth putting lots of the loads onto the leisure battery like radio and things like that if not you probably have a problem inside of the vehicle discharging the battery
@andrzejkwiatos7378
@andrzejkwiatos7378 Ай бұрын
what size fuse should be used at the input from the alternator to Orion XS?
@gd4997
@gd4997 Ай бұрын
Really interesting. Can it be used with a D+ signal (not ignition) and if so how?
@johannesboonstra6917
@johannesboonstra6917 Ай бұрын
Yes , there is a remote port for this But through a setting this can be automatically switching as well
@benshke
@benshke Ай бұрын
Quick question, in the dc dc charging from starter battery to living battery if the engine is running and the starter battery gets disconnected does the dcdc charger still works? Could you test this? Been searching for days on info on this on the inter webs and couldn't find any info.
@asennaydenov6461
@asennaydenov6461 14 күн бұрын
Hi! Recently I’ve installed XS and have found out right after the engine is on there is a disturbance on the VHF especially on channel 16 from the XS device. Test with oscilloscope shows the distribution frequencies on the negative side. When I connect the old Orion 30A the issue disappears…. As I understood this is well known issue with XS, do have a solution for this problem?
@RealeaD
@RealeaD 18 күн бұрын
does it reverse charge? In my country, temperature drops to -30 in winter. My car has Eberspacher engine heater and when I preheat the engine, it runs on the starter battery and very cold weather is bad for the battery at the same time. So, I am considering installing a DC DC charger with reverse charge function, which way I can bring my portable power station to the car before preheating the engine and connect it to the DC DC charger to protect the starter battery. My questions are: does it reverse charge? if so, will that function work in very cold, say -30. (Your website says it has low temp protection)
@johannesboonstra6917
@johannesboonstra6917 18 күн бұрын
No, it does not reverse charge , you could have a separate dcdc converter (switched) for that function.
@RealeaD
@RealeaD 17 күн бұрын
@@johannesboonstra6917 Thanks for the reply. In that case, I might consider Ecoflow charger which supports reverse charge according to sources
@dantheman6698
@dantheman6698 3 ай бұрын
12v input to 48v ~1kw output is what interests me. could use it on an old car alternator powered by an old lawnmower engine instead of using expensive generators that keep failing.
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 3 ай бұрын
yes I know, it will come, not any time soon though
@brianwadsworth5752
@brianwadsworth5752 3 ай бұрын
I see in the liturature that this charge controller has a low temporature cutout. Can this feature be turned off? I have a 300 ah lifepo4 self heating house battery. At low ambient temperatures, I need the charge controller to be able to be energized, and to push power to the battery heaters via the bult in battery BMS. Once the battery has warmed up, and the heaters have turned off, I need the charge controller to charge the battery, even in low ambient temperartures. Will this charge controller allow me to configure it to turn off the low temperature cutout?
@Jsak666
@Jsak666 3 ай бұрын
Can you tell me what the charge current limiters can go to? Can the input current be changed to sub 10amp so this can potentially be used to plug into a 12v 10amp cigarette socket and use that as the charge input rather than the alternator??? This feature is exactly what I have been looking for so I can use my portable battery in both my work car that has alternator connection, but then move the battery to my partners car and use the cigarette socket without blowing the fuse. If it can do that then consider it sold!
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 3 ай бұрын
it can be less then 10A indeed , but then a 50A unit is overkill right?
@Jsak666
@Jsak666 3 ай бұрын
@@JohannesBoonstra-ol2nz that's great thanks, but it won't be overkill as the battery spends majority of the time in my work truck getting 50amp charge, weekend trips in the other car where I don't want to run a cable from the starter battery and can use the 12v cig socket would be perfect for the odd occasion
@Paul_______
@Paul_______ 3 ай бұрын
Very nice. Any worf if the Phoenix series of inverters will receive larger VA units in 120v lile 1600 or 2000?
@roboda1
@roboda1 2 ай бұрын
Hi, new user on fresh install in Motorhome. On the app, Is there a way to change the picture of a battery showing charging level to a percentage? I have the direct wired wall display that shows battery percentage but it doesn’t show on the app. Thanks
@johannesboonstra6917
@johannesboonstra6917 2 ай бұрын
The data comes from a Orion or other device, so if that doesnt know the battery capacity, it can also not show this I am afraid
@romeobravo3793
@romeobravo3793 3 ай бұрын
Great. Are you planning to launch a 24V | 24V 40A version as well?
@VictronEnergyBV
@VictronEnergyBV 3 ай бұрын
Yes, also expected end of this year.
@berndkleiner7031
@berndkleiner7031 3 ай бұрын
Excellent, can't wait to get it. Ideally a 24/24 50A version... Where can I get updates on availability?
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 3 ай бұрын
@@berndkleiner7031 this will be shared on the socials as soon as there is news.
@berndkleiner7031
@berndkleiner7031 4 күн бұрын
The year is coming to an end very soon, and you shared the information that a 24/24 XS is coming this year. Are there delays or will it be presented as a Christmas surprise? ​@JohannesBoonstra-ol2nz
@steveanderson9135
@steveanderson9135 3 ай бұрын
Can I assume an isolated version is coming soon ? Thank you.
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 3 ай бұрын
it is in development but not delivered any time soon as we have prioritized the 24/48 models and higher power units.
@shane7969
@shane7969 26 күн бұрын
you dont need to isolate it. it only activates after it senses the voltage increase when you start the engine and the alternator puts out power so the starter battery is never at risk of being depleted
@shanesummerhayes7101
@shanesummerhayes7101 3 ай бұрын
With a GX controlled system, is the XS DVCC ready?
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 3 ай бұрын
Yes !
@ianrobinson6788
@ianrobinson6788 Ай бұрын
Reportedly the current model can interfere with VHF communications which, for boat installations at least, is a bit of an issue. Is this being addressed?
@johannesboonstra6917
@johannesboonstra6917 Ай бұрын
Hello, any piece of electron can/will interfere and also a XS, there are guideline what level this should be and the XS is not crossing any lines there. They are close to be honest so there are some changes implemented to have these parts were they are close to another band.
@ianrobinson6788
@ianrobinson6788 Ай бұрын
Thank you. Is it possible to describe the changes that might help with the problem if it occurs?
@johannesboonstra6917
@johannesboonstra6917 Ай бұрын
@@ianrobinson6788 the filters will be adapted do that the spikes on specific bands will be shifted to areas they are less probable to cause any interference. PS we dont levels above the required levels as it is, its just an improvement
@ianrobinson6788
@ianrobinson6788 Ай бұрын
Thank you.
@crew0791
@crew0791 2 ай бұрын
which ground does the DC to DC connect to? The lithium and all the victron gear go into smart shunt into the lithium negative. The starter battery grounds to the chasis. Does this need to ground to car or shunt?
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 2 ай бұрын
Normally there is a common ground (beside systems which have isolated circuits of course) , When using a Smartshunt the load side is grounded so thats also the place for the XS to be connected
@crew0791
@crew0791 2 ай бұрын
@@JohannesBoonstra-ol2nz thanks for the reply. Is the load side of the smarthsunt considered a common ground in a typical setup? I haven't done any wiring yet, just laying it and had a decision on where to ground the XS. No issues running to the smarthsunt just wasn't sure how the lead acid circuit worked if its not grounding to the smart shunt also.
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 2 ай бұрын
@@crew0791 yes, the Load side is also the common ground side ( as otherwise the shunt doesnt see 'all' current
@JdZ-2023
@JdZ-2023 3 ай бұрын
What is it's own power dissipation? How mutch is the efficiency?
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 3 ай бұрын
please have a look at 0;45 sec again...
@JdZ-2023
@JdZ-2023 3 ай бұрын
​@JohannesBoonstra-ol2nz , that is at 50A, so the power consumption is negligible. If it's the same at 5A, then it's a lot.
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 3 ай бұрын
@@JdZ-2023 self consumption as listed on the datasheet is
@UKsystems
@UKsystems 2 ай бұрын
@@JdZ-2023 why do you want to charge at very low current with this unit? You really need to get one which is not such high current
@SAMSUNGTABLET-uh9is
@SAMSUNGTABLET-uh9is 3 ай бұрын
Ha comentado que sirve para todo tipo de baterías, pero se puede instalar cuando la batería de arranque es de plomo y la de servicio de lifepo4,( o hay que instalar algún mecanismo intermedio) , gracias
@superjetsi3653
@superjetsi3653 3 ай бұрын
Is there any way to have this in stand alone mode while still being monitored on a gx device thats running dvcc? I have a system where the xs is changing an agm from the lithium but external control takes over when the ve direct cable is plugged in.
@UKsystems
@UKsystems 2 ай бұрын
Quite simply you can’t have something running in standalone road when it’s connected to a controller you can change the configuration to allow it to function with different parameters
@brotheradam
@brotheradam 3 ай бұрын
ok, we also need to be able to drop from 48 v solar to 24 or 12 v sub systems.. especially given the costs now to keep 12 v stuff going..plus need to be able to set up direct 20 or 18v charging for tool batteries instead of only running inverters to charge power tools
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 3 ай бұрын
48V solar to 24?, thats a MPPT charge controller right? thats already there
@UmbrellaProject6790
@UmbrellaProject6790 3 ай бұрын
Kann man mit dem MK3 Interface direkt in das Venus fahren und dann über den Wechselrichter die Werte ändern oder müsste man das RJ45 Kabel beim Venus ausstecken
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 3 ай бұрын
The XS can (only) be adjusted using Victron Connect app/programm. not though an inverter or such I am afraid
@UmbrellaProject6790
@UmbrellaProject6790 3 ай бұрын
@@JohannesBoonstra-ol2nz Doch wenn das ganze System vernetzt ist aber Ich das Kabel vom Venus GX abstecken muss um die Batteriespannung in Volt zu programmieren und wenn man direkt daneben mit dem -MK3 Interface reinfahre über das Venus GX ob es einen Schaden verursachen würde das meine Ich Anders kann Ich es nicht mehr erklären Der Phoenix Inverter wird mit dem RJ45 Kabel mit dem MK3 Interface gesteckt/verbunden und über das VEConfig die Batterieunterspannung programmiert das der Wechselrichter Sich automatisch ein und ausschalten kann, oder über die Handy App Die Frage wäre ob man Sich das abstecken des Kabels aus dem Venus sparen könnte
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 3 ай бұрын
@@UmbrellaProject6790 why have a cable unplugged ? you can control with bluetooth quite easy the XS while the system is running. Beside this, charge settings are only needed when first installing or swapping batteries, its not normally often changed
@Stefanie_on_the_Road
@Stefanie_on_the_Road 3 ай бұрын
I pre-ordered it and it was delivered straight after the release. and I really have to say I'm very happy with it. I previously had the DC-DC 12-12/18, which was already very hot. I really like the fact that you can set the charging current, in my case ‘only’ 40 amps, and the option of configuring it via cable for data transfer to the Cerbo. I am thoroughly satisfied with it. Victron electrifies my Vanlife ❤
@VictronEnergyBV
@VictronEnergyBV 3 ай бұрын
We are glad to hear that, thank you very much for your kind words!
@fred-n6f
@fred-n6f 3 ай бұрын
why not an isolated version?
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 3 ай бұрын
thats make the unit more costly and the volume is in not isolated, but there will be isolated versions in the future
@HybridShedIraq
@HybridShedIraq 3 ай бұрын
What is the obsession with isolation in the USA why not use ground 🤔 .
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 3 ай бұрын
@@HybridShedIraq ;-)
@sailingadventurous784
@sailingadventurous784 3 ай бұрын
⁠​⁠@@HybridShedIraqon a boat we typically don’t have a metal chassis to use as earth.
@tonycarey1808
@tonycarey1808 Ай бұрын
So does anyone have an idea when the isolated version is coming
@johannesboonstra6917
@johannesboonstra6917 Ай бұрын
That will be not before end next year I am afraid
@tonycarey1808
@tonycarey1808 Ай бұрын
@@johannesboonstra6917 I've been advised by local marine electrician I can use the XS with a single ground wire to the negative bus bar from the bats.
@robink.9459
@robink.9459 3 ай бұрын
FINALLY! The old 30A Orion is such terrible design. It overheats all the time reducing output power due to it's bad efficiency - even with an external fan attached to the massive heat sink. I will throw out that thing as soon as the isolated XS comes to market. Love all my other Victron devices though
@tyler0487
@tyler0487 3 ай бұрын
How hot does this device get under full load? The old Orion's would reduce power output because they were so hot and this one seems to have no heat sink...
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 3 ай бұрын
same here, but due to a higher efficiency they get less warm so will work longer at max power.
@shanec.7105
@shanec.7105 3 ай бұрын
Its about time they come up to modern standards- engine on and off sensing. I had the old version and ran my battery down by not turning the on and off switch. Because of that, switched to Ecoflow. If price is right, this is the game changer.
@UKsystems
@UKsystems 2 ай бұрын
However, Victron devices are part of an ecosystem you could have introduced engine on and off detection if you configure the devices in such a way
@mikegyver3193
@mikegyver3193 3 ай бұрын
The problem with Victor excellent supply of products, is that if there’s ever an EMP problem, the whole system is wiped out. Or somebody can hack into your Wi-Fi and wipeout your system.
@JohannesBoonstra-ol2nz
@JohannesBoonstra-ol2nz 3 ай бұрын
Is there a brand in electronics different on tis prospective?
@andrewford80
@andrewford80 3 ай бұрын
If there is ever an EMP we have much bigger problems on our hands. I think you've been watching too many movies
@erikj9962
@erikj9962 3 ай бұрын
The solution is to buy 2 and keep the backup in a Faraday cage
@UKsystems
@UKsystems 2 ай бұрын
Why would you like your Victron energy gear to survive an EMP but everything else that its powering to fail? It seems pointless doesn’t it that way? You can easily configure that your GX device is not allowed to change settings from the Internet but you make this comment without without doing any research. If you completed their training courses it would literally tell you all of this.
We Attempted The Impossible 😱
00:54
Topper Guild
Рет қаралды 54 МЛН
Why the grid caused this Dutch campsite solar to blow up
10:37
Victron Energy
Рет қаралды 39 М.
STILL too hot?! 🔥🥵 Orion XS 50A test & unboxing.
18:58
EXPLORIST life Mobile Marine & Off-Grid Electrical
Рет қаралды 47 М.
How To Wire a Renogy  DC to DC Charger Without Spending Hours On It!
8:39
Dirtbags with Furbags
Рет қаралды 33 М.
The Best New Battery Chargers For Your Van
14:47
Van Land
Рет қаралды 21 М.
Inside the Victron MultiPlus & a Detailed Explanation of How It Works
19:13
How to not blow up your Alternator when charging Lithium
7:51
Victron Energy
Рет қаралды 1,2 МЛН
The New 50A Orion Dc Dc Charger... Everything You Need to Know.
8:07
EXPLORIST life Mobile Marine & Off-Grid Electrical
Рет қаралды 66 М.