Nice watching you sir bon, my idol and together your team.
@BonMj Жыл бұрын
Thanks
@salimagwan9672 Жыл бұрын
Sir, I watch every video of yours, we are getting to learn a lot from you, we eagerly wait for your videos. To check the head compressor, we can also check setting 2-28, comp 1, comp 2 by setting checker instead of compressor
@BonMj Жыл бұрын
👍👍
@Didik-cq8wy Жыл бұрын
Trimakasih bos surabaya jawa timur
@BonMj Жыл бұрын
👍👍
@reubenbugeja4066 Жыл бұрын
Thanks for sharing mr bon!If inverter board needs to be replaced this model guess tou have to empty refrigerant.
@BonMj Жыл бұрын
No need.
@reubenbugeja4066 Жыл бұрын
If someday you replace one,can you be so kind and share it please!! Thanks
@j26a24d Жыл бұрын
New York city presente 👍good video thanks you
@BonMj Жыл бұрын
Welcome
@GodofredoTalin7 ай бұрын
thank you teacher Bon👍👍👍
@BonMj7 ай бұрын
You are welcome!
@akzcreation7339 Жыл бұрын
Hi ,Bon nice to meet you , I also working SINGAPOR
@BonMj Жыл бұрын
👍
@jonasalmonicar15788 ай бұрын
Good day sir bon..im your number 1 viewer..i always watch your video to learn more about from you..question..can i do this bypass at VRV X series? Can you make a video to return the bypass from its normal operation after replace the compressor..thanks in advance..more power for your channel❤
@BonMj8 ай бұрын
Thanks
@BonMj8 ай бұрын
Single cu or multi cu
@jonasalmonicar15788 ай бұрын
Multi indoor ceiling cassette..master and slave outdoor
@IMAGINE-069565 ай бұрын
Good job dear ❤
@BonMj5 ай бұрын
Thank you 😊
@RamKrishna-zb5ng Жыл бұрын
Good work sir nice, ,🎇 from india
@BonMj Жыл бұрын
Thanks
@pjstv5833 Жыл бұрын
Nice sir bon...
@BonMj Жыл бұрын
Thanks
@peramaraj2763 Жыл бұрын
Thanks for your update video sir
@BonMj Жыл бұрын
Welcome
@aymanharris4599 Жыл бұрын
So was the inverter board bad for second compressor or the compressor was bad? You checked the ohms and they checked out ok?
@MedridAATOUN Жыл бұрын
Thank you ❤
@BonMj Жыл бұрын
Welcome!
@oiltubewalker Жыл бұрын
Q1#_ In the operation sequence of the both compressor, the INV 1 shld be fail first as compare to INV 2(lower demand), why the INV comp 2 fail in the first place?? Q2#_ Why the guy didn't use the Megger meter to mega the INV 2 compressor? What's the normal range of the ohm of the compressor? Please kindly clear the doubts for us.Thanks
@ankushgupta973 Жыл бұрын
Osm sir
@ankushgupta973 Жыл бұрын
We like u every videos sir love u sir
@BonMj Жыл бұрын
Thanks
@HoàngNgọc-s6s5 ай бұрын
Good job,thanksyou
@BonMj5 ай бұрын
Welcome 👍
@Marcoguima45 Жыл бұрын
Good Job!😎🇧🇷
@BonMj Жыл бұрын
Thanks bro
@Didik-cq8wy Жыл бұрын
Trimakasih bos
@BonMj Жыл бұрын
👍
@karaors8970 Жыл бұрын
Nice job bro . 🧿🛠️🤳👍🇹🇷
@BonMj Жыл бұрын
Thanks bro
@arifbabulotapalkatti7643 Жыл бұрын
Thanks bro
@BonMj Жыл бұрын
Welcome
@MasterJay2611 ай бұрын
Sir how/ where did you get service manuals of different models of Daikin unit?🙏
@antanasrudminas9414 Жыл бұрын
👍👍👍
@BonMj Жыл бұрын
Thanks
@Raam19778 ай бұрын
Mr. Bon I want to tutorial from you what is the procedure I'm living in singapore
@yerayrm83 Жыл бұрын
hello bon what solution do you have the change of compressor 1
@BonMj Жыл бұрын
Compressor 2 and inverter pcb
@yerayrm83 Жыл бұрын
@@BonMj ok friend 👍
@adeelashraf5141 Жыл бұрын
Hello bon sir how r u.sir I want to came thir and work with u. ilove this work to much.allready I have a ac repairing work shop in Saudi Arabia.but I want to came thir and work with u.whats a process plz can u guide me or can u help me
@adeelashraf5141 Жыл бұрын
Iam waiting for your answer
@adeelashraf5141 Жыл бұрын
Help me plz
@salamsaloom2477 Жыл бұрын
👍👍👍👍👍👍👍
@BonMj Жыл бұрын
Thanks
@mohammedshoaibsaiyed3901 Жыл бұрын
Hi mr.bon problem is compressor?? circuit?
@geovannialcoriza588 Жыл бұрын
Mr.Bon how to bypass for vrv 2 if sleve 1 compressor is broken?
@mahalakshmimaha9739 Жыл бұрын
For activate and deactivate both same ....Mode 2 and press set button39 time and press return 1 time and press set button 1 time ,again press return button twice
@hidayaturrokhman3538 Жыл бұрын
Is this the case of single outdoor, Mr. Bon?
@BonMj Жыл бұрын
Yes.single cu
@moorthilatha5739 Жыл бұрын
Hi sir thank you u sharing video i have 1 question RXQ10TY1 error code E2-01 We change high pressure sensor, compressor and inverter pcb already replaced done and low pressure sensor ohms ok .but still E2-01 blinking any other solution ?
@BonMj Жыл бұрын
Try check thermistor
@peramaraj276310 ай бұрын
Hi sir I have a doubt vrv-4 master unit's inverter comp-01 we can do bypass ?
@ronaldoxotza91458 ай бұрын
Yes you can. In vrv 4 you can do bypass to all the compressors. Either you have a system vrv or a single unit .except vrv 3 you can do bypass compressors only if we have a single unit. If we have a system you can bypass only a unit. Tech me Mr bon mj 😉
@peramaraj27638 ай бұрын
@@ronaldoxotza9145 Mitsubishi city multi (VRF) unit how to bypass including connected by CRC system
@sabujsarkar7962 Жыл бұрын
Hlo sir I am very interested for your working still I am very impressed Sir. So I have a joine Your team please.
@KalabogbosyotvHenrygalicia8 ай бұрын
Sir bon mj help me for may VRV4 the error is uf-01 in outdoor and L5 in indoor RXQ18TY1
@BonMj8 ай бұрын
UF check indoor LEV and thermistor L5 check inverter pcb and compressor
@abdulthoufiq640210 ай бұрын
What is mean by VRV Daikin TFA error code LC
@yudhistira5209 Жыл бұрын
Siir , fan 2 running but fan 1 not running ,commpressor 1 running &compressor 2 runinng, we done reset fan 2&1working but 5 minute fan 1 not working again 'but nothink code error what's problem siir ?
@BonMj11 ай бұрын
Pressure ok?
@meherphilippo16704 ай бұрын
I have alarm E2. 01 master thermostat and outdoor L5. 06 fan only runing command go to compressor second than off
@Mentri7610 ай бұрын
with codes L5-5 and JA-9, please help, Mr Bon?
@Mentri7610 ай бұрын
Model RXQ12AY14
@BonMj10 ай бұрын
L5-5 check slave 1 inverter pcb and compressor JA-9 check slave 1 high pressure sensor
@Mentri7610 ай бұрын
@@BonMj thank you mr bon
@josephnkpoyen1655Ай бұрын
I have a unit blinking LC -14 error. How do I reset that, please?
@BonMjАй бұрын
Check outdoor fan Pcb
@ataufikqurrahman7450 Жыл бұрын
Sir, i need solutions, inverter compressor 1 cable connected to grounding, 400 ohm, is teh compressor , code error e2-01, please reply🙂
@ataufikqurrahman7450 Жыл бұрын
History error code f3-20, and L8-
@BonMj Жыл бұрын
Check high low pressure switch first
@ataufikqurrahman7450 Жыл бұрын
Thanks,
@ataufikqurrahman7450 Жыл бұрын
Switch loh high no problem,
@ataufikqurrahman7450 Жыл бұрын
Selanjutnya periksa komponen apa pak?
@amirulmirul7307 ай бұрын
Boss. I want ask. Vrv error code l5-14 what problam?
@BonMj6 ай бұрын
Check inverter pcb or inverter compressor
@peramaraj2763 Жыл бұрын
I have a doubt sir system-4 ,03 nos of FCU is running as normal but 01 nos of FCU set point-23 the thermistor reading is 00-26.4C,01-24C, 02-07C, 03-10C the room thermistor can't decrease so what is the problem could you give me some tips sir ?
@BonMj Жыл бұрын
If 02=7 03=10 Mean is ok.no problem
@peramaraj2763 Жыл бұрын
@@BonMj but customer i ask why haven't decrease room temperature always stable 26 to 26.7 like this bro
@BonMj Жыл бұрын
@@peramaraj2763 air flow ok?
@peramaraj2763 Жыл бұрын
@@BonMj air flow ok bro
@peramaraj2763 Жыл бұрын
3 .2 m/s
@jpmyname5724 Жыл бұрын
sir...numpang tanya kode error E2 -02 utk ac central daikin RXQ14AY14.. 1 sistem 2 outdoor...masalahnya apa sir? xie2
@BonMj Жыл бұрын
Check sub cu high low pressure sensor dulu atau compressor tak baik
@jpmyname5724 Жыл бұрын
@@BonMj siap sir...xie2
@vijaygani1179 Жыл бұрын
Vrf puhy p200 yhm mitsubishi error code can't show. run few minutes and off.pls can give some ideas
@BonMj Жыл бұрын
Do you check error at cu
@vijaygani1179 Жыл бұрын
Cu side no error code.
@BonMj Жыл бұрын
@@vijaygani1179 use wire remote check indoor error
@joelnoumesi410 ай бұрын
I ei I want to join your team I work on Daikin In Cameroon
@BonMj10 ай бұрын
👍
@ibrahimqiqi5761 Жыл бұрын
ما هو سبب كود خطأ U3-02
@BonMj Жыл бұрын
Test run or indoor got error
@Mangashraf02 Жыл бұрын
Sir mau tanya kode eror e2 -81 fan idup kompresor gak mau hidup
@BonMj Жыл бұрын
Check inverter pcb
@Mangashraf02 Жыл бұрын
Kpna ya sir awalnya eror e2 trus u4 sekrang e5 ganti2
@akashshaw214 Жыл бұрын
Hlw sir i have a problem there is 3 vrv system 12 hp 12 hp 12 hp at one site they are showing error L5-03.
@akashshaw214 Жыл бұрын
Vrv x
@BonMj Жыл бұрын
Check compressor and inverter pcb
@akashshaw214 Жыл бұрын
Compressor is good
@akashshaw214 Жыл бұрын
But i have about inverter pcb
@BonMj Жыл бұрын
@@akashshaw214 check the master unit inverter pcb and compressor
@chhayachhan29227 ай бұрын
Ask how to check code 1
@binhdinhthanh20017 ай бұрын
Can you give me code error VTV ? Thank you
@Actechnicianofficialchannel5 ай бұрын
Yah wala error code Kahan milega
@BonMj4 ай бұрын
From 7 segment light
@shepherdmutambiranwa4251 Жыл бұрын
I'm having LC 02 on cassette
@BonMj Жыл бұрын
Check inverter pcb and control pcb
@AnantPrajapati-VRVАй бұрын
Hello sir i am anant prajapati frome India my daikin vrv error code E0 please help me
@satbirsingh88171 Жыл бұрын
Sir vrv 4 error L5 After 1hour ronning
@BonMj Жыл бұрын
Check inverter pcb.
@VincentChali-ny6hi9 ай бұрын
None a zad
@akashshaw214 Жыл бұрын
Compressor 2 was in good condition then why change both inverter pcb&compressor
@ubongu1149 Жыл бұрын
E English
@chungwhasan Жыл бұрын
Please don't put ay back ground music! very annoying!!
@BonMj Жыл бұрын
👌
@AnantPrajapati-VRVАй бұрын
Hello sir i am anant prajapati frome India my daikin vrv error code E0 please help me