WAGO 222 - The flexible all-rounder

  Рет қаралды 332,069

WAGO Germany

WAGO Germany

Күн бұрын

Пікірлер: 83
@ckmass5614
@ckmass5614 10 жыл бұрын
Biggest advantage of these Wago connectors is that they can handle both solid and stranded wires, and wires of dissimilar diameters, better than twist-on connectors.
@damienbender213
@damienbender213 2 жыл бұрын
I'm balls deep into Wagos.👍
@clubagreenie
@clubagreenie 6 ай бұрын
Thats gotta hurt when the levers down
@pinkymixology4965
@pinkymixology4965 6 жыл бұрын
I can't believe I used to wire anything without these...
@mybb9200
@mybb9200 7 жыл бұрын
German ingenuity and quality at it's best 👍
@Faddnn
@Faddnn 6 жыл бұрын
And the new 221 is even better!
@davidthomas2348
@davidthomas2348 3 жыл бұрын
Duuuh ..... ! They're Danish notGarman.
@IAmThe_RA
@IAmThe_RA Жыл бұрын
​@@davidthomas2348They are German
@RadioRich100
@RadioRich100 Жыл бұрын
Thats why they lost the war.
@RadioRich100
@RadioRich100 2 ай бұрын
Thats why they lost the war.
@ooltimu
@ooltimu 5 жыл бұрын
What is the electrical resistance of the connection? What is the contact surface of the conductor to the inner plate and the current carrying surface of the inner plate? Thank you!
@WAGO_Germany
@WAGO_Germany 5 жыл бұрын
The connectors are released according EN 60998. In this standard the requirement is to have a voltage drop per contact less than 22,5 mV under full load. Our 222 series passed this tests with safety distance to the required limits. The surface of the current bar is a special tin mix which is developed by WAGO to ensure the long time high contact quality.
@RadioRich100
@RadioRich100 Жыл бұрын
@@WAGO_Germany there should be NO VOLTAGE DROP at all in any connection no matter what!
@derdrache0512
@derdrache0512 Жыл бұрын
⁠@@RadioRich100unfortunately a voltage drop hapens because of electical resistance. Every wire has a voltage drop, every connector has a voltage drop, everything that conducts electricity has a resistance and thus a voltage drop.
@RadioRich100
@RadioRich100 Жыл бұрын
@@derdrache0512 Direct copper to copper has no voltage drop, as there is no connector. The wire nut merely protects the conductors which make there own connection. Wagos are like putting resistors in series with the circuit held together by springs which lose their spring via time and heat. They fail over time in different ways. No reason to use them other than speed. Haste makes waste!
@farmerdave7965
@farmerdave7965 8 жыл бұрын
I am now in love with WAGO connectors. Goodbye wire nuts.
@Dinco422
@Dinco422 2 жыл бұрын
Yeah man I never knew why ppl used wire nuts when these things exist.... sooo fun to use them :)
@RadioRich100
@RadioRich100 Жыл бұрын
And hello fires and failures.
@AlpineTheHusky
@AlpineTheHusky 2 ай бұрын
@@RadioRich100 Well they are intended to be used by professionals or people who understand how to use them, not by you.
@RadioRich100
@RadioRich100 2 ай бұрын
Because you dont know what your doing.
@RadioRich100
@RadioRich100 2 ай бұрын
@@Dinco422 Yeah they are probably made by lego. How old are you?
@seroberts1
@seroberts1 8 жыл бұрын
A very well thought out and inexpensive product.
@RadioRich100
@RadioRich100 Жыл бұрын
A piece of junk for people that dont know what there doing.
@ellescer
@ellescer Жыл бұрын
How long have these been around? 20 years? Surprised people don’t really use them. Although I’m starting to see a lot in prefabricated led fixtures
@WAGO_Germany
@WAGO_Germany Жыл бұрын
Yes, nearly 20 years now! 👍😊
@alanfranb
@alanfranb 4 жыл бұрын
will the 222 accept a crimped 1.5mm cable
@WAGO_Germany
@WAGO_Germany 4 жыл бұрын
Dear Alan, yes, you can use a crimped 1.5 mm cable for the 222. Best regards from the WAGO Team
@rappcantik1739
@rappcantik1739 3 жыл бұрын
i want to buy mounting carrier from ebay or lazada but cant find it
@carlosh448
@carlosh448 7 ай бұрын
Aluminum to copper?
@WAGO_Germany
@WAGO_Germany 7 ай бұрын
Yes, the 222 can be used in conjunction with the Alu-Plus contact paste for aluminum conductors. Kind regards from the WAGO Team
@carlosh448
@carlosh448 6 ай бұрын
@@WAGO_Germany what is the ingredients on the ALU-Plus paste ?
@WAGO_Germany
@WAGO_Germany 6 ай бұрын
These are hydrocarbons and silicon oxide.
@deskaryanugraha4331
@deskaryanugraha4331 4 жыл бұрын
Is using this wago product safe to use for all cable connections in home electrical installations?
@WAGO_Germany
@WAGO_Germany 4 жыл бұрын
WAGO’s 222 Series is suitable for standard building installations.
@RadioRich100
@RadioRich100 Жыл бұрын
No way, they burn, melt, levers pop open, wire moves inside the body when working in the box and there in series with the load.. Nothing is better that a good twisted copper to copper connection.
@IAmThe_RA
@IAmThe_RA Жыл бұрын
​@@RadioRich100Maybe you don't know how to use them properly. Have used them for a decade with zero issues.
@IAmThe_RA
@IAmThe_RA Жыл бұрын
​@@RadioRich100 American/Canadian electrics should belong in a museum 😅
@RadioRich100
@RadioRich100 Жыл бұрын
@@IAmThe_RA Anybody knows how to use them, the thing is you shouldnt use them. I guess when you put them in you attach your name and phone # to each one with instructions to call you if the circuit burns or fails.
@Optimuztube
@Optimuztube 7 жыл бұрын
I like these alot, looking at the video it seems like they are using rk.... is that ok?
@tanoryjakaperdana1419
@tanoryjakaperdana1419 2 жыл бұрын
Whats the 32A rate for? AC or DC?
@WAGO_Germany
@WAGO_Germany 2 жыл бұрын
Hi Tan Ory Jaka Perdana, for AC and DC. Kind regards from the WAGO Team
@tanoryjakaperdana1419
@tanoryjakaperdana1419 2 жыл бұрын
@@WAGO_Germany ok thanks
@grahamd5418
@grahamd5418 3 жыл бұрын
I have two lots or wire twisted together. For example. Two lives,two neutrals and two earths. I want to run a spur off them. Can I separate the two wires,run them in to the connector and connect the spur wire into the third slot? Would the circuit still be continuous?
@WAGO_Germany
@WAGO_Germany 3 жыл бұрын
Dear Graham, a terminal must be used for each potential because it is bridged internally. Kind regards from the WAGO Team
@tropicaldimitri7374
@tropicaldimitri7374 2 жыл бұрын
All lives go to into one connector, all neutrals into another connector and all earths into another connector. So in your case you need 3 connectors. Hire an electrician if you need help, don't mess with electricity.
@artbag10
@artbag10 5 жыл бұрын
Can you use just 2 cables in a triple connector unit?
@R900DZ
@R900DZ 5 жыл бұрын
Arthur Ravenscroft yes
@darthroon1
@darthroon1 4 жыл бұрын
Will these work on my shower wire 10mm
@rayc1503
@rayc1503 4 жыл бұрын
I'm afraid not, the 222 do a max of 4mm cable diameter where as the 221 can cover upto 6mm max. 10mm would need to be joined via a readily accessible junction box or back to the shower switch or consumer unit.
@reynaldomendoza6911
@reynaldomendoza6911 6 жыл бұрын
I've been use it how to purchase it
@reynaldomendoza6911
@reynaldomendoza6911 6 жыл бұрын
I've been it I love it how to purchase it
@alphaindustries5775
@alphaindustries5775 4 жыл бұрын
These things are honestly amazing. like 32 amps?!?!?!?!?!?
@thomasgrafe8767
@thomasgrafe8767 2 жыл бұрын
Der alte Klassiker. :-)
@kaybhee6
@kaybhee6 2 жыл бұрын
solid wire ,, many sizes,, brands,,, freely wiggle sideways.. not enough contact area
@hellopellos
@hellopellos Жыл бұрын
???
@kaybhee6
@kaybhee6 2 жыл бұрын
very little contact inside
@WAGO_Germany
@WAGO_Germany 2 жыл бұрын
Dear kay bhee, you can be sure that there is enough contact inside! Best regards from the WAGO Team
@debeeriz
@debeeriz 6 жыл бұрын
does the sp2 which is the back to back model connect side by side (like the 412) or back to back (like a terminal block) or both eg all 4 coonected as 1
@WAGO_Germany
@WAGO_Germany 6 жыл бұрын
Hello debeeriz, the back to back terminals under the name spl(x) are based on the design of the WAGO Series 222, but are not WAGO products. They in no way meet our quality requirements. Best regards Your WAGO-Team
@ТапокПравосудия-н3ш
@ТапокПравосудия-н3ш 4 жыл бұрын
А разве можно пихать многожильный провод без наконечника?
@WAGO_Germany
@WAGO_Germany 4 жыл бұрын
Dear Андрей Гуглович , yes, there is no need to use a ferrule. Best regards from the WAGO Team
@lewisjsuk1
@lewisjsuk1 10 жыл бұрын
No, No, No, No, No! You should never, never, ever crimp the end of a crimp bucket! The crimp should always be some distance away from the end of the crimp bucket, to avoid putting a stress point and likely failure point in the wire as it exits the crimp. When the crimp is correctly located on the crimp bucket, some way from the end, it allows the crimp to naturally flare out and stress relieves the wires as they exit the crimp. He was doing quite a nice job up until that point!
@Ts6451
@Ts6451 10 жыл бұрын
Well, the parts of the Wago 222 system is designed to work together the way shown in the video, obviously this only applies to this specific system, other ways of splicing wires in an installation may have other strain relief requirements. I expect the reason they can use such short strain relief on these is that the spring based cage clamps are resistant to issues caused by thermal expansion/contraction and vibration, there is no screws to work loose or that can be over/under tightened and the spring ensures the clamping pressure is maintained as long as the conductor is within the clamp. Wago has been making connectors based on their cage clamp technology for decades, and as far as I know has a good reputation for reliability, so I would expect they know what their technology requires to be reliable. Those levers can be a bit hard on the fingers though...
@lewisjsuk1
@lewisjsuk1 10 жыл бұрын
Don't know what happened there, that comment I left was nothing to do with Wago terminals, but a chap using a crimp splice with a hex die on a group of wires, where he crimped the entire length of the barrel and didn't leave a flare where the wires entered the crimp! How it got associated to this video I don't know!
@giopa110888
@giopa110888 3 жыл бұрын
@@lewisjsuk1 then delete your comment for f*ck sake.
@abelchang8367
@abelchang8367 3 жыл бұрын
"By using the 222 Series splicing connectors, you can connect solid conductors with a cross section of 0.08 to 4 mm² and fine-stranded and stranded conductors with cross sections from 0.08 to 2.5 mm². " ------------------- IT IS WRONG . !!!!!!!!!!!!!!!!!!!!!!!!!
@WAGO_Germany
@WAGO_Germany 3 жыл бұрын
Dear Abel Chang, thank you for your annotation! You are right - we had a typing error in the numbers, which we have changed now. Best regards from the WAGO Team
@GB-ud6yg
@GB-ud6yg 2 жыл бұрын
Craziest thing I learned from this video is that it’s pronounced WAH-go not WAY-go.
@tropicaldimitri7374
@tropicaldimitri7374 2 жыл бұрын
The correct German pronunciation is VAH-gaw
@tropicaldimitri7374
@tropicaldimitri7374 2 жыл бұрын
The correct German pronunciation is VAH-gaw
@mactheknife4786
@mactheknife4786 5 жыл бұрын
Where’s number 6? What have Wago got against the number six damnit!? In truth, I couldn’t give a monkey’s uncle because they’re the best connectors in the entire west, and likely as not, east too! They’re bleedin’ brilliant, especially for prototyping etc. Give them a shot, you’ll never go back to wirenuts or rising clamps.
@RadioRich100
@RadioRich100 2 ай бұрын
Only a misinformed fool thinks like this. Leave electrical work to those who know how to do it.
@literoadie3502
@literoadie3502 5 жыл бұрын
Tiny contact area.
@pomidortv797
@pomidortv797 4 жыл бұрын
I see much clones..
What Wire Connector is the Best? Settling a Debate! Wire Nut VS Wago
11:09
Mom Hack for Cooking Solo with a Little One! 🍳👶
00:15
5-Minute Crafts HOUSE
Рет қаралды 23 МЛН
Quando eu quero Sushi (sem desperdiçar) 🍣
00:26
Los Wagners
Рет қаралды 15 МЛН
Wire/Splicing Connectors: 221 Product Comparison
3:14
WAGO United States
Рет қаралды 80 М.
Cum facem ,corect,legaturile in doze cu Cleme Wago
13:51
Proiectediversediy
Рет қаралды 73 М.
Which Splicing Device is Best?  Push Ins Vs. Wago Vs. Wirenuts
13:06
How To Home
Рет қаралды 1,5 МЛН
I Discovered This Hidden Wiring Trick In An Old Forum!
9:24
LRN2DIY
Рет қаралды 708 М.
2 BRILLIANT Splicing Devices Many Believe Will Replace WAGOs!
15:07