Water Load Accident ❌ Big Generator Load Trial 1010KVA | 4K

  Рет қаралды 47,912

SURAJ DIESEL GENERATOR

SURAJ DIESEL GENERATOR

11 ай бұрын

Пікірлер: 48
@alisaad4913
@alisaad4913 7 ай бұрын
Hello bhai generator safe hai na
@surajdieselgenerator
@surajdieselgenerator 7 ай бұрын
Haa ji bilkul safe ha
@mcpehindi434
@mcpehindi434 4 ай бұрын
😂😂
@eduardosanchez7827
@eduardosanchez7827 20 күн бұрын
I appreciate greatly this kind of video showing the dangers of such maneuver. I’m not criticizing at all, actually this shows that the whole operation must be carried with more precautions. Thank you so much for posting this 👍🏻. Most people only show how to do it but it’s important to also address the possible problems. Thanks again from Mexico! 🇲🇽
@surajdieselgenerator
@surajdieselgenerator 20 күн бұрын
@@eduardosanchez7827 Thank you for understanding our motive to upload the video. 😊
@PortableGeneratorServices
@PortableGeneratorServices 6 ай бұрын
That blue tank is maybe large enough for a 15kw unit for a short time. You do not want the water boiling like that. With the water boiling like shown the plates can not stay 100% in contact with the water. The water is being blown away from the plates due to the boiling. Boiling allows air pockets Resulting in the fluctuating amperage. Salt is not necessary if the tank is large enough. I did 2 such load bank jobs in a fresh water river. Never remove the plates until the breaker is opened. The separation of the plates needs to be much greater - we separated our plates about 16”. Whoever was in charge should be fired - very dangerous setup.
@surajdieselgenerator
@surajdieselgenerator 6 ай бұрын
I appreciate your review. But the salt here is used to Check the load on instant. The mistake here happened was. While we were not available our 1 engineer put salt on the Backalite. And that salt didn’t dissolved. You might hai seen dropping salt many times. That’s because we have changed water and added fresh water again. My motive here of uploading video was. In india this technique is used since 1990s. I want to teach our brothers that these kind of accidents can take place. Thank you 😊
@JPcostarica27
@JPcostarica27 5 ай бұрын
Is ok that plates are in line? I mean, should they be placed forming a triangle to guarantee a load balanced?
@PortableGeneratorServices
@PortableGeneratorServices 5 ай бұрын
@@JPcostarica27 for a resistive load not needed
@galponeroserial
@galponeroserial 22 күн бұрын
There is no risk of electrolysis products to be released creating a near explosive atmosphere?
@sree6127
@sree6127 3 ай бұрын
No safety
@unknowncoder2037
@unknowncoder2037 6 ай бұрын
Sir kya bliss ka jo engine ata tha kirloskar electric dg set me bo engine achha hei long lasting hoga plz help kijiye mujhe me kharidna chata hun ek admi se isiliye ouch raha hunn engine kesa hei alternotr kesa hei 62 kva ka dg set hei plz reply
@surajdieselgenerator
@surajdieselgenerator 6 ай бұрын
Aap whatsapp kijiye photos. Ham bata denge uski condition +919033353459
@argosy440
@argosy440 3 ай бұрын
What happens when it arcs like that? Does the generator automatically switch off?
@surajdieselgenerator
@surajdieselgenerator 3 ай бұрын
If the ACB breaker contains Earth Fault Relay. The Breaker will shut down. But Generator won’t stop you have to stop it.
@billmoran3812
@billmoran3812 6 ай бұрын
That drum is way too small for the kind of power being dissipated. Way too much salt too. Boiling that hard will further concentrate the salt causing a runaway condition. Essentially that’s what happened when they pulled the electrodes out. Very salty water dripping off close spaced electrodes caused the arcing. Extremely dangerous. They need a tank of water about 10 times larger for a generator that size. And much bigger electrodes spaced at least 2-3 feet apart.
@surajdieselgenerator
@surajdieselgenerator 6 ай бұрын
Actually the problem occur was due to our engineer put salt on the backalite. It should have been properly dissolved in the water. That salt did the spark
@sahilrathod1684
@sahilrathod1684 Күн бұрын
125 kv price ? Adressss
@patel6228
@patel6228 11 ай бұрын
😱
@zs6vl
@zs6vl 4 ай бұрын
Those guys are a walking accident.
@surajdieselgenerator
@surajdieselgenerator 4 ай бұрын
Dude. Get a life. We are doing much better than you. Go and work.
@ghostcrusher5169
@ghostcrusher5169 4 ай бұрын
@@surajdieselgenerator I agree with you
@ghostcrusher5169
@ghostcrusher5169 4 ай бұрын
Look at urself before commenting
@teresashinkansen9402
@teresashinkansen9402 3 ай бұрын
480VX421A=202kW If that water barrel holds 190L at 20C° that means it will reach 100C° in about 5 minutes or about 1 minute at full power. That water resistor is way undersized. Also do not take out the electrodes with power on! that's why such thing happened.
@surajdieselgenerator
@surajdieselgenerator 3 ай бұрын
Basically the load varies. But the calculations you gave is top notch. We will consider it.
@tjc-gaby9687
@tjc-gaby9687 2 ай бұрын
480v ou 400v ?
@ghostcrusher5169
@ghostcrusher5169 6 ай бұрын
Is this Cummins Genset?
@surajdieselgenerator
@surajdieselgenerator 6 ай бұрын
Yes Cummins KTA3067 SERIES
@sahilshaikh6290
@sahilshaikh6290 5 ай бұрын
Mccb trip huva ki nahi
@surajdieselgenerator
@surajdieselgenerator 5 ай бұрын
MCCB nhi ACB aata hai. Or trip hua.
@nothing12299
@nothing12299 2 ай бұрын
V16 turbocharged?
@surajdieselgenerator
@surajdieselgenerator 2 ай бұрын
Yes. V16 Turbocharged 3067 Litres of displacement.
@nothing12299
@nothing12299 2 ай бұрын
@@surajdieselgenerator ok thanks for the information
@vikrammalviya7917
@vikrammalviya7917 11 ай бұрын
Sir esa ku hogya.
@surajdieselgenerator
@surajdieselgenerator 11 ай бұрын
Excessive Salt Use ho gaya. Salt dalne wale ne Salt ko paani me nhi milaya. Usse BAKALITE me blast ho gaya. Or Load Bank Pighal gaya
@vikrammalviya7917
@vikrammalviya7917 11 ай бұрын
@@surajdieselgenerator sir i really appreciate your work and your response 👍👍
@surajdieselgenerator
@surajdieselgenerator 11 ай бұрын
@@vikrammalviya7917 thank you 😊
@bigmuller1
@bigmuller1 7 ай бұрын
That is not a good way to do a load test
@surajdieselgenerator
@surajdieselgenerator 7 ай бұрын
Yes we know. But the load banks are way too costlier to purchase and to maintain. So we have this alternative. Which is risky. But the footage you saw is rare of rare incidents happened.
@urboydexter
@urboydexter 6 ай бұрын
​@@surajdieselgenerator so do you guys plan to get the one which is safe
@surajdieselgenerator
@surajdieselgenerator 6 ай бұрын
@@urboydexter Yes we are planning to make one instead of buying.
@wiltonsurya4600
@wiltonsurya4600 2 ай бұрын
too much salt
@surajdieselgenerator
@surajdieselgenerator 2 ай бұрын
Yes excess 🧂
Test beban genset 114 kva mwm stamford
6:31
yohanes supardi
Рет қаралды 3,5 МЛН
FULL RESTORATION VIDEO: Diesel Generator 4.5kw Old YaBiSi
24:42
Fully Restoration Solution
Рет қаралды 310 М.
Survive 100 Days In Nuclear Bunker, Win $500,000
32:21
MrBeast
Рет қаралды 81 МЛН
How to start up a Marine Diesel Engine
9:35
Genius at Work
Рет қаралды 1,3 МЛН
How to make a FREE ENERGY generator with CAR ALTERNATOR and a MOTOR
21:45
The Crazy Channel
Рет қаралды 863 М.
Big Generator Engines Startup Sound That Will Make You Sleep 1
31:07
Techno Fusion HD
Рет қаралды 63 М.
Portable Generator End Testing (AVR & Brush)
15:23
MAC TECH
Рет қаралды 215 М.
MEGA Cold Smoke DIESEL GENERATOR Engine Starts and Heavy Sound 2
5:01
Cars and Engines
Рет қаралды 478 М.
Generator Starting problems and troubleshoot
7:44
DIY & Fix it
Рет қаралды 36 М.
How to turn a washing machine motor into a 250v generator
10:05
Nice Creation
Рет қаралды 3,2 МЛН
Lavage de voiture 😂
0:21
Nicocapone
Рет қаралды 3 МЛН
РЕЗКА РЕЗИНЫ ДЛЯ ШИН
0:40
MakkClips
Рет қаралды 9 МЛН
Eksperimen!! Modifikasi Sepeda Jok Paddock Sepeda
0:36
aseli bmx
Рет қаралды 1,1 МЛН