Week 9 Electrical Exam Prep Video Series, Journeyman and Master Electrician Exam Series 2017/2020

  Рет қаралды 18,715

Electrical Exam Coach

Electrical Exam Coach

Күн бұрын

Пікірлер: 20
@joshuafrank9084
@joshuafrank9084 2 жыл бұрын
your videos are amazing.... Very detailed, you cover all confusing concepts perfectly . I wish I found them sooner, Thank you!
@steveterry54
@steveterry54 Жыл бұрын
After I finish this course, I plan to spend a week or two going through some practice exams, then take the test. My goal is to take the test before the end of February this year. If I had to leave my state, I'd move to Texas.
@Electricalexamcoach
@Electricalexamcoach Жыл бұрын
You can do it!
@charlesaverette7560
@charlesaverette7560 2 жыл бұрын
Adjust before correcting
@ryanw8203
@ryanw8203 2 жыл бұрын
What if the wire type is not listed under the 90* C column? or what if the test asks for an adjustment for a wire rated 75* or 60* ? or what if its asking to adjust types TW, US or MN?
@juniorfigo
@juniorfigo Жыл бұрын
I have the 2017 Codebook, in there you can refer to Table 310.104(A) thru (E) that explains the maximum operating temperatures of different Conductors
@SayMore11
@SayMore11 2 жыл бұрын
strange that my UL listed romex NM B 6/0 cable isn't listed in my 20/20 NEC book.
@TheeAMPchannel
@TheeAMPchannel Жыл бұрын
Tuesday! Mansfield,Texas to work at Klein Factory.
@Electricalexamcoach
@Electricalexamcoach Жыл бұрын
That's awesome!
@carbq5280
@carbq5280 Жыл бұрын
Took my first test 2 years ago, failed it and took it again 1 month later I decided electrical wasn't for me anymore and walked out like 5 minutes into the second try, I never studied or prepared in anyway until now.
@Electricalexamcoach
@Electricalexamcoach Жыл бұрын
You can do it bro! electricalexamcoach.com
@dorianpadilla9338
@dorianpadilla9338 10 ай бұрын
U the goat!
@franciscoherrera3780
@franciscoherrera3780 Жыл бұрын
HI SIR .WHAT ABOUT ROUND UP THE NUMBERS
@arnieselectric007
@arnieselectric007 Жыл бұрын
Hey Perry, I'll probably schedule my Master's test middle of April...and Tennessee maybe around Savanah or Dyersburg, not sure yet...also, would like info on Electrical Inspector too...
@Electricalexamcoach
@Electricalexamcoach Жыл бұрын
See you at the top!
@ammaraldulaimi3237
@ammaraldulaimi3237 2 жыл бұрын
The examples for more than 3 conductors adjustment said the size of the conductor then said installed in a pipe with 3 current conductors doesn't that make the total 4 conductors ?
@DanielaHotea-m9q
@DanielaHotea-m9q 9 ай бұрын
For the question regarding #10 wire THWN-2 with ambient temp of 142- if following the ** next to 10 on the amp table it states to follow 240.4 D which states after temp correction should not exceed 25 amps, does this not apply to this question?
@texasdailytrucks8165
@texasdailytrucks8165 2 жыл бұрын
When doing the question about 142F THHW on the code book 2020. THHW it’s on the 75 degrees Column and 90 degrees column. Why you choose the 90 column instead the 75? Did I missed a step?
@Electricalexamcoach
@Electricalexamcoach 2 жыл бұрын
For derating you will use the 90° C column as long as it's listed in there even if it's listed in both
@dicknastee1652
@dicknastee1652 Жыл бұрын
What's the situation where your Ampacity is divided by the bundling adjustment and or correction factor??? Ex: 44A/ .91 x .80….. conductor sizing??? Examples please. Thanks
ПРИКОЛЫ НАД БРАТОМ #shorts
00:23
Паша Осадчий
Рет қаралды 4,6 МЛН
Grounding and Bonding 250.66 LIVE
1:02:43
Electrical Code Coach
Рет қаралды 4,7 М.
25 Electrical Exam Prep Practice Test Questions with full explanations VOL 1
47:27
Rule 12 910 Conduit Fill
41:51
Canadian Electrical Code
Рет қаралды 1,4 М.
240.4  &  T-310.16  Conductor Protection and Ampacity
22:48
Dave Gordon
Рет қаралды 45 М.