It is used to kill the vacuum or break vacuum inside condenser.
@motive0507 Жыл бұрын
Sir,does that initial heating line is for increasing the inside surface temp of FST?
@kpatelbla Жыл бұрын
Yes
@motive0507 Жыл бұрын
For what purpose sir?
@kpatelbla Жыл бұрын
Initial heating of FST water to prevent hammering
@motive0507 Жыл бұрын
@@kpatelbla sir,if you don't mind please explain clearly
@kpatelbla Жыл бұрын
Initially Deaerator FST temperature at atmospheric and after starting of steaming in Boiler we can not take this water through Bfp otherwise there will be chances of hammering that is why initial heating must be charged
@ashutoshsingh1137 Жыл бұрын
Sir, in few units TDBFP at TG floor and few units TDBFP at zero meter why????
@kpatelbla Жыл бұрын
This is depends upon NPSH of TDBFP.
@ashutoshsingh1137 Жыл бұрын
@@kpatelbla sir any factor TDBFP turbine??? Only npsh of main pump..
@kpatelbla Жыл бұрын
@@ashutoshsingh1137 Only source steam & Exhaust steam piping are constraint nothing else.