DIFFERENT BETWEEN POWER TRANSFORMER AND CURRENT TRANSFORMER?
WHY CT SHOULD NOT KEEP OPEN?
IS IT CT WILL BLAST WHEN IT KEEP OPEN.
WHAT HAPPEN IF INSULATION FAIL ON CT?

Пікірлер: 18
@abhipower8026
@abhipower8026 11 ай бұрын
Nice explanation brother... Now iam your new subscriber
@baranitech1026
@baranitech1026 11 ай бұрын
Thanks and MOST welcome
@amitpagare5946
@amitpagare5946 10 ай бұрын
Very informative video 🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏
@baranitech1026
@baranitech1026 10 ай бұрын
So nice of you, thanks lot
@alhaseef8268
@alhaseef8268 10 ай бұрын
Hai Mr barani, what will happen if we use low ratio ct for the high current conductor. Example using 30/1 instead of 100/1. Please advise
@baranitech1026
@baranitech1026 10 ай бұрын
CT life time will effect very much and also easily get saturation during heavy fault condition.
@selvakumart108
@selvakumart108 11 ай бұрын
Hi sir, I have a question why does the power transformers don't blast when then the secondary side opens? Even the power transformers also have backemf to counter the main emf of power transformer?
@baranitech1026
@baranitech1026 11 ай бұрын
POWER TRANSFROMER -ALSO HAVE CORE LOSS IN NO LOAD BUT WHEN SECONDARY OPEN THE PRIMARY CURRENT WILL BECOME ZERO. SO THE SECONDARY VOLTAGE CREATE WILL BE AS PER NAME PLATE. ( SIMPLE -MATCHING PRIMARY VA = SECONDARY VA)
@selvakumart108
@selvakumart108 11 ай бұрын
@@baranitech1026 thanks sir
@raj3094
@raj3094 11 ай бұрын
Very nice session
@baranitech1026
@baranitech1026 11 ай бұрын
Thank you
@sivananthambalasubramanian1202
@sivananthambalasubramanian1202 11 ай бұрын
Barani sir. Put some video on battery, battery charger and tap cell purposes.
@baranitech1026
@baranitech1026 11 ай бұрын
i will make for you
@saravanakumar9916
@saravanakumar9916 11 ай бұрын
Hi sir i have doubt in relay stator earth thrid harmonic protection
@saravanakumar9916
@saravanakumar9916 11 ай бұрын
how to check in relay
@baranitech1026
@baranitech1026 10 ай бұрын
for testing need to injected 3rd harmonic voltage to the relay.
@electricalwithprd
@electricalwithprd 11 ай бұрын
First views ❤
@baranitech1026
@baranitech1026 11 ай бұрын
Most welcome
TRANSFORMERS - THE SECONDARY SIDE - CALCULATING AMPERAGE
2:36
Mark Overgaard
Рет қаралды 18 М.
Why CT secondary can’t be kept open circuited | Explained | TheElectricalGuy
14:32
Gaurav J - TheElectricalGuy
Рет қаралды 16 М.
WORLD'S SHORTEST WOMAN
00:58
Stokes Twins
Рет қаралды 74 МЛН
Transformer Insights: Will Secondary Load Impact the Primary Current?
13:34
Gaurav J - TheElectricalGuy
Рет қаралды 6 М.
Why CT Secondary is always closed | Why CT secondary is never kept open| Hindi
4:59
Electrical With Abhishek Joshi
Рет қаралды 67 М.
Current Transformer types every Electrical Engineer should know | TheElectricalGuy
16:58
Gaurav J - TheElectricalGuy
Рет қаралды 10 М.
Transformer Open Circuit Test
3:45
schulerruler
Рет қаралды 41 М.
5P10 & 5P20 Class of Current Transformer | Explained | TheElectricalGuy
11:16
Gaurav J - TheElectricalGuy
Рет қаралды 20 М.
The Impact of DC Supply on Transformers | Explained with Simulation | TheElectricalGuy
16:17